1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21517-0 SANS 50362:2008Edition 2EN 362:2004Edition 2SOUTH AFRICAN NATIONAL STANDARD Personal protective equipment against falls from a hei

4、ght Connectors This national standard is the identical implementation of EN 362:2004 and is adopted with the permission of CEN, rue de Stassart 36, B-1050 Brussels. Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 15

5、68 www.sabs.co.za SABS SANS 50362:2008 Edition 2 EN 362:2004 Edition 2 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee SABS SC 94A, Personal protective equipment Industrial safety belts, fall arrest systems and industrial rope a

6、ccess, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in September 2008. This SANS document supersedes SABS EN 362:1992 (first edition). EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 362 Decem

7、ber 2004 ICS 13.340.99 Supersedes EN 362:1992 English version Personal protective equipment against falls from a height - Connectors quipement de protection individuelle contre les chutes de hauteur - Connecteurs Persnliche Schutzausrstung gegen Absturz - Verbindungselemente This European Standard w

8、as approved by CEN on 20 October 2004. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such

9、national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language an

10、d notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, N

11、etherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2004 CEN All rights of exploitation in

12、any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 362:2004: EEN 362:2004 (E) 2 Contents page Foreword3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Requirements.7 4.1 General7 4.2 Static strength8 4.3 Gate function8 4.4 Gate resistance (not for cla

13、ss Q-connectors).8 4.4.1 Gate face.8 4.4.2 Gate side.8 4.5 Corrosion resistance.9 4.6 Marking and information.9 5 Test methods9 5.1 Examination of design 9 5.1.1 General9 5.1.2 Verification of the gate opening.9 5.2 Static strength test 9 5.2.1 Apparatus .9 5.2.2 Preparation of test samples9 5.2.3 M

14、ethod 10 5.3 Gate function test 12 5.4 Gate resistance tests.12 5.4.1 Gate face.12 5.4.2 Gate side.13 5.5 Corrosion test 14 6 Marking .14 7 Information supplied by the manufacturer .15 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 8

15、9/686/EEC16 EN 362:2004 (E) 3 Foreword This document (EN 362:2004) has been prepared by Technical Committee CEN/TC 160 “Protection against falls from height including working belts”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, eit

16、her by publication of an identical text or by endorsement, at the latest by June 2005, and conflicting national standards shall be withdrawn at the latest by June 2005. This document supersedes EN 362:1992. This document has been prepared under a mandate given to CEN by the European Commission and t

17、he European Free Trade Association, and supports essential requirements of EU Directive 89/686/EEC. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of

18、the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spai

19、n, Sweden, Switzerland and United Kingdom. EN 362:2004 (E) 4 1 Scope This document specifies the requirements, test methods, marking and information supplied by the manufacturer for connectors. Connectors conforming to this document are used as connecting elements in personal fall protection systems

20、, i.e. fall arrest, work positioning, rope access, restraint and rescue systems. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the r

21、eferenced document (including any amendments) applies. EN 363, Personal protective equipment against falls from a height Fall arrest systems. EN 364:1992, Personal protective equipment against falls from a height Test methods. EN 365, Personal protective equipment against falls from a height General

22、 requirements for instructions for use, maintenance, periodic examination, repair, marking and packaging. EN 20139:1992, Textiles Standard atmospheres for conditioning and testing (ISO 139:1973). ISO 9227, Corrosion tests in artificial atmospheres Salt spray tests. 3 Terms and definitions For the pu

23、rposes of this document, the terms and definitions given in EN 363 and the following apply. 3.1 connector openable device used to connect components, which enables the user to assemble a system in order to link himself/herself directly or indirectly to an anchor 3.2 self-closing connector connector

24、with a self-closing gate 3.3 basic connector (class B) self-closing connector intended to be used as a component, see Figure 1 3.4 multi-use connector (class M) basic or screw link connector intended to be used as a component, which may be loaded in the major and minor axis 3.5 termination connector

25、 (class T) self-closing connector designed to allow the fixing as an element of a sub-system in such a way that the loading is in a predetermined direction, see Figure 2 3.6 anchor connector (class A) connector which closes automatically, designed to be linked directly to a specific type of anchor a

26、s a component, see Figure 3 NOTE Types of anchors are e.g. an eye-bolt, a pipe or a beam. EN 362:2004 (E) 5 3.7 screwlink connector (class Q) connector which is closed by a screw-motion gate, which is a load bearing part of the connector when fully screwed up (see Figure 4), intended to be used only

27、 for long-term or permanent connections 3.8 gate part of the connector which can be moved to open it NOTE The gate can, for example, move by pivoting about a hinge (hinged gate), or by a sliding motion (sliding gate) or by a screw motion (screw-motion gate). 3.9 self-closing gate gate which moves au

28、tomatically to the closed position when released from any open position 3.10 self-locking gate self-closing gate with an automatic gate-locking feature 3.11 manual-locking gate self-closing gate with a manually operated gate-locking feature 3.12 gate-locking feature mechanism which, when in position

29、, prevents the closed gate being opened inadvertently. A gate-locking feature may operate automatically (to the locked position) or be operated manually 3.13 gate opening maximum gap for the passage of an element or a component into the connector and which allows the correct functioning of the gate-

30、locking feature, see Figure 5 EN 362:2004 (E) 6 Figure 1 Example of basic connector (class B) a) Manual locking b) Automatic locking Figure 2 Example of termination connectors (class T) Figure 3 Example of anchor connectors (class A) EN 362:2004 (E) 7 Figure 4 Example of a screwlink connector (class

31、 Q) Key a gate opening Figure 5 Example of a gate opening 4 Requirements 4.1 General 4.1.1 Connectors shall not have sharp edges or burrs that may cause injury to the user, or that may cut, abrade or otherwise damage webbing or rope. 4.1.2 Materials, which may come into contact with the skin of a us

32、er, shall not be known to cause irritating and sensitization effects during normal use of the connector. 4.1.3 Connectors with a gate shall have a gate-locking feature, either automatic or manual. EN 362:2004 (E) 8 4.1.4 Connectors with a self-locking gate shall lock the gate automatically when the

33、gate shuts, and shall require at least two different deliberate manual actions to open the gate. 4.1.5 Connectors with a manual-locking gate, except screwlink connectors, shall require a deliberate manual action to lock the gate, and shall require at least two different deliberate manual actions to

34、open the gate. 4.1.6 Screwlink connectors shall require at least four complete rotations of the screw-motion gate from the fully screwed up position to disengagement of the threads. The threads shall not be visible when the gate is locked. 4.1.7 The gate opening a shall be determined as described in

35、 5.1.2 and verified that it is not less than that given by the manufacturer. 4.2 Static strength When tested in accordance with 5.2, connectors shall withstand the load specified in Table 1 for a period of 3 min 3 s. At the end of the test, the gate shall still be closed. Table 1 Minimum static stre

36、ngth requirement for connectors Description Major axis Gate closed and unlocked kN Major axis Gate closed and locked kN Minor axis Gate closed kN Basic connector (class B) 15 20 7 Multi-use connector (class M) 15 20 15 Termination connector (class T) 15 20 Not applicable Anchor connector (class A) 1

37、5 20 Not applicable Screwlink connector (class Q) Not applicable 25 10 4.3 Gate function When tested as described in 5.3, with the gate closed and locked, connectors with the exception of anchor connectors (class A) shall still open after being loaded to 6 kN. 4.4 Gate resistance (not for class Q-co

38、nnectors) 4.4.1 Gate face After testing with a force of (1 0,02) kN in accordance with 5.4.1, the gate-locking feature of connectors shall still function correctly. Where the gate locking feature does not encircle the connector body, e.g. Figure 2b) and Figure 3, the gate-locking feature shall withs

39、tand a force of (1 0,02) kN without separating from the latch by more than 1 mm. 4.4.2 Gate side When tested in accordance with 5.4.2, connectors with a gate locking feature that does not encircle the connector body, e.g. Figure 2b) and Figure 3, shall withstand a force of (1,5 0,03) kN without any

40、partial fracture. After this test the gate-locking feature shall still function correctly. EN 362:2004 (E) 9 4.5 Corrosion resistance When tested in accordance with 5.5, connector gates shall still function in accordance with 4.1.4. Evidence of corrosion of the base metal is not acceptable. The pres

41、ence of tarnishing and white scaling is acceptable. NOTE Conformity to this requirement does not imply suitability for use in a marine environment. 4.6 Marking and information 4.6.1 Marking of connectors shall be in accordance with Clause 6. 4.6.2 Information shall be supplied with connectors in acc

42、ordance with Clause 7. 5 Test methods 5.1 Examination of design 5.1.1 General One sample may be used for these tests. Check that the connectors, in accordance with the definitions in Clause 3, meet the requirements of 4.1.1 to 4.1.7 by visual examination and simple check measurements. 5.1.2 Verifica

43、tion of the gate opening Verify the gate opening a by using a calibrated rod which has a diameter corresponding to the gate opening specified in the information supplied by the manufacturer, see Figure 5. Pass the rod through the gate opening and check that it allows the correct closure and locking

44、of the gate and free movement of the rod within the connector. 5.2 Static strength test 5.2.1 Apparatus The static strength test apparatus is a conventional tensile testing machine. The force measuring apparatus for static testing shall conform to EN 364:1992, 4.1.1.The rate of loading shall lie wit

45、hin the range of 50 mm/min to 200 mm/min if the connector contains a textile element subject to stress during the test; or 20 mm/min to 50 mm/min otherwise. 5.2.2 Preparation of test samples a) Test samples containing a textile element shall be conditioned in accordance with EN 20139 at the standard

46、 temperate atmosphere for testing and shall include the relevant pre-conditioning specified in Clause 3 of that document. The static strength tests can be performed outside the conditioning room, but the temperature shall be (23 5) C and the tests shall begin within 5 min of removal from conditionin

47、g. b) Test samples without a textile element may be tested without conditioning. c) Each test shall be carried out on a new sample. EN 362:2004 (E) 10 5.2.3 Method 5.2.3.1 Major axis testing Mount the connector in the tensile testing machine and apply the load by means of two bars with a radius of (

48、6 0,1) mm, which are arranged to be perpendicular to the major axis. It is important that the connector is free to locate itself on the bars at the start of the test and as the load is applied. The bars shall be well coated with molybdenum based grease where they come into contact with a metal part

49、of the test sample. If the connector is tested in a horizontal axis test machine, the connector shall be positioned in a vertical plane with the gate being the lower of the two major axis sides. If the connector is tested in a vertical axis test machine, apply a small force to the connector at right angles to the direction of loading to bias the gate away from the bars initially. The bias force shall be approximately equal to the gravitational weight of the connector. Apply the required minimum force in accordance with Table 1 or in acc