TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf

上传人:fuellot230 文档编号:1060500 上传时间:2019-03-31 格式:PDF 页数:14 大小:322.16KB
下载 相关 举报
TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf_第1页
第1页 / 共14页
TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf_第2页
第2页 / 共14页
TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf_第3页
第3页 / 共14页
TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf_第4页
第4页 / 共14页
TIA-455-84-B-1998 FOTP-84 Jacket Self-Adhesion (Blocking) Test for Optical Fiber Cable《FOTP-84 光缆的套管自粘(粘连)试验》.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 TIA DOCUMENT FOTP-84 Jacket Self-Adhesion (Blocking) Test For Fiber Optic Cable TIA-455-84-B (Revision of EIA-455-84-A) APRIL 1998 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of NOTICE TIA Engineering Standards and Publica

2、tions are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular n

3、eed. The existence of such Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Publications. Neither shall the existence of such Documents preclude their voluntary use by non-TIA members, either domestically or

4、internationally. TIA DOCUMENTS TIA Documents contain information deemed to be of technical value to the industry, and are published at the request of the originating Committee without necessarily following the rigorous public review and resolution of comments which is a procedural part of the develo

5、pment of a American National Standard (ANS). Further details of the development process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm TIA Documents shall be reviewed on a five year cycle by the formulating Committee and a decisio

6、n made on whether to reaffirm, revise, withdraw, or proceed to develop an American National Standard on this subject. Suggestions for revision should be directed to: Standards & Technology Department, Telecommunications Industry Association, 2500 Wilson Boulevard, Arlington, VA 22201 U.S.A. (From Pr

7、oject No. 3-3854, formulated under the cognizance of the TIA FO-4.7 Subcommittee on Optical Cables.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 1998 Standards & Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of TIA TELECOMMUNIC

8、ATIONS INDUSTRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-7179) International (303-397-7956) or search online at http:/www.tiaonline.org/standards/search_n_order.cfm All rights reserved Printed in U.S.A. NOTICE OF DISCLAIMER AN

9、D LIMITATION OF LIABILITY The document to which this Notice is affixed (the “Document”) has been prepared by one or more Engineering Committees or Formulating Groups of the Telecommunications Industry Association (“TIA”). TIA is not the author of the Document contents, but publishes and claims copyr

10、ight to the Document pursuant to licenses and permission granted by the authors of the contents. TIA Engineering Committees and Formulating Groups are expected to conduct their affairs in accordance with the TIA Engineering Manual (“Manual”), the current and predecessor versions of which are availab

11、le at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm. TIAs function is to administer the process, but not the content, of document preparation in accordance with the Manual and, when appropriate, the policies and procedures of the American National Standards Institute (“ANSI”). TIA doe

12、s not evaluate, test, verify or investigate the information, accuracy, soundness, or credibility of the contents of the Document. In publishing the Document, TIA disclaims any undertaking to perform any duty owed to or for anyone. The use or practice of contents of this Document may involve the use

13、of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from

14、 the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA does not enforce or monitor compliance with the contents of the Document. TIA doe

15、s not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FIT

16、NESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NON-INFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTE

17、NTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM

18、 OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TOR

19、T (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. PLEASE! DONT VIOLATE

20、THE LAW! This document is copyrighted by the TIA and may not be reproduced without prior permission of the Telecommunications Industry Association. For information consult our website at http:/www.tiaonline.org/about/faqDetail.cfm?id=18 Organizations may obtain permission to reproduce a limited numb

21、er of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 U.S.A. or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 STD-EIA TIA-455-84B-ENGL 1772 111 3234bOO Ob14352 55b 111 TlNEIA

22、-455-84B FOTP-84 Jacket self-ad hesion (blocking) test for optical fiber cable Contents . Foreword I I I Introduction . 1 Normative references I A p pa ra tu s . .2 Sampling and specimens 3 Procedure . .3 Calculations or interpretation of results . 4 Documentation . .5 Specification information .6 A

23、nnex A . 7 I STDOEIA TIA-q55-84B-ENGL 1772 H 3234b00 Ob1Li353 472 D TIAfEIA-455-84B FOTP-84 Jacket self-adhesion (blocking) test for optical fiber cable Foreword (This Foreword is informative only and is not part of this Standard). This FOTP is from TIA Standards Proposal No. 3854, formulated under

24、the cognizance of TIA FO-6.7, Subcommittee on Fiber Optic Cable. This FOTP is part of the series of test procedures included within Recommended Standard TINEIA-455. NOTE: This FOTP was previously published in EIA-455-84B as FOTP-84. There is one annex, which is informative. Key words: Sticking, temp

25、erature iii Previous page is blank STD-EIA TIA-iSS-AYB-ENGL 1992 3234b00 ObL4354 327 TINE IA-455-848 FOTP-84 Jacket self-adhesion (blocking) test for optical fiber cable I Introduction The intent of this test is to investigate the ability of the jacket, insulation, or other outer covering of fiber o

26、ptic cable on a reel, drum, or spool, to withstand elevated temperature for prolonged periods of time without sticking to itself on adjacent turns or layers. 2 Normative references The following documents form a part of this FOTP to the extent specified herein: EIA/TIA-455-A, Standard test procedure

27、s for fiber optic fibers, cables, transducers, sensors, connecting and terminating devices, and other fiber optic components, FOTP-13 (EIA-455-13), Visual and mechanical inspection of fibers, cables, connectors and/or other fiber optic devices. 1 STDSEIA TIA-455-BqB-ENGL 1772 E 3234b00 Ob14355 2b5 T

28、INEIA-455-84B 3 Apparatus The following apparatus and equipment is required to perform this test: 3.1 Metal spool Use a metal spool which has a barrel or drum diameter of 30 to 50 times the outside diameter of the fiber optic cable under test. The flanges of the spool shall be such that the ends of

29、the cable specimen can be attached to them. 3.2 Chamber Use a test chamber with a volume of sufficient size such that the specimen within it will not interfere with the generation and maintenance of the prescribed test conditions. The heat source shall be located such that the radiant heat will not

30、fall directly on the specimen. 3.3 Temperature probe Unless othewise specified, use thermocouples or equivalent temperature sensors to determine the temperature within the chamber and to control the chamber temperature. 2 4 Sampling and specimens TINEiA-455-84B The test specimen shall be a represent

31、ative sample of a completed fiber optic cable. Specimen length shall be at least 1,500 times the finished diameter of the cable (see 5.2). 5 Procedure 5.1 Attach one end of the cable specimen to the spool. 5.2 Wind three layers of the specimen cable on the spool drum with a minimum of three close tu

32、rns in each layer such that the wind arrangement is mechanically stable. Excercise care to ensure that the individual turns are in intimate contact with the adjacent turns. Winding tension shall be uniform and sufficient to ensure intimate contact on the spool. Minimum winding tension shall be 10 N

33、(2.25 Ibf). 5.3 After winding, attach the remaining (outside) end of the specimen to the spool and secure it in such a manner as to ensure that no unwinding or loosening of the specimen can occur 5.4 Place the spooled specimen in the test chamber. Unless otherwise specified in the Detail Specificati

34、on, maintain the temperature of the chamber at 71 5 2 OC for a period of 48 hours. 5.5 After temperature conditioning has been completed, remover the spooled specimen from the chamber and allow it to return to room temperature. (In case of dispute, refer to the standard atmospheric conditions of EIN

35、TIA-455-A.) 5.6 After the spool has stabilized at room ambient, manually unwind the entire cable specimen from the spool while evaluating it for any unwinding difficulty, and while visually examining for evidence of adhesion (blocking) of adjacent turns. Refer to FOTP-I 3, but note that magnificatio

36、n is not required except in case of dispute. 3 TINEIA-455-846 6 Calculations or interpretation of results 6.1 Calculations No calculations are required by this procedure. 6.2 Interpretation Interpret and report the extent of adhesion according to the following criteria: CRITERIA CLASSIFACTION CODE O

37、BSERVEDRESULTS OF ADHESION A No Adhesion None B C D 6.3 Precision and bias Specimen easily removed. Mild Cosmetic damage only. Specimen removed with some Moderate difficulty. Slight damage consisting, for example, of pieces of the covering (cable jacket) removed so that the cross-sectional area of t

38、he cable is altered, but not to such a degree that the cable core is exposed. The functional integrity of the cable is not jeopardized. Specimen cannot be removed Severe (unwound) without catastrophic damage (for example, cable core exposed). The functional integrity of the cable Ueopardized. The pr

39、ecision of this test has not been determined. No statement can be made about the bias of this test for jacket self adhesion since the result merely states whether there is conformance to the criteria for success specified in the procedure or Detail Specification. 4 STD-EIA TIA-455-84B-ENGL 1792 3234

40、b00 Ob14358 T74 TINE lA-455-84 B 7 Documentation 7.1 Report the following information for each test: 7.1.1 Date of test. 7.1.2 Identification of procedure used (FOTP-84 and title). 7.1.3 Identification of the fiber optic cable tested and any other applicable data, including measured outside cable di

41、ameter. 7.1.4 Drum or barrel diameter of spool. 7.1.5 Test conditions (test time and temperature). 7.1.6 Results of the examinations (classifications of adhesion). 7.1.7 Other significant information to provide documentation and traceability of the test equipment, methods, operation, or other releva

42、nt information. 7.2 United States military applications require that the following information also be reported for each test. For other (nonmilitary) applications, this information need not be reported but shall be available for review upon request. 7.2.1 Test personnel. 7.2.2 Specific information

43、on test equipment used (e.g., model numbers, serial numbers, etc., and calibration dates). 5 STD.EIA TIA-455-ti4B-ENGL 1992 D 323Yb00 Ob14359 900 D TINEIA-455-84B 8 Specification information The following information shall be specified in the Detail Specification: 8.1 A reference to this test proced

44、ure if it is to be used. 8.2 Exceptions or deviations that apply to this test procedure. 8.3 Acceptance or failure criteria, using codes (6.2) or other requirements. 8.4 Test duration and number of samples to be tested. 8.5 Testing temperature, if other than specified in 5.4. 6 STD-EIA TIA-455-84B-ENGL 1792 = 323i-ib b143b b22 TINE lA-455-84 B Annex A (informative) Comparison between this FOTP and IEC or ITU-T requirements It should be noted that, as of this publication date, there are no known IEC or ITU-T test methods that are comparable to this FOTP. 7