1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1034 Burglary-Resistant Electric Locking MechanismsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHO
2、RIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Burglary-Resistant Electric Locking Mechanisms, UL 1034 Sixth Edition, Dated May 18, 2011 Summary of Topics This revision of ANSI/UL 1034 was issued to incorporate the changes to the Electrical Trans
3、ient Tests, Section 44. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated September 5, 2014. For further information regarding Summary of Requirements, please visit https:/ Text that has been changed in any manner or impacted by ULs electronic pu
4、blishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL pro
5、vides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss
6、 of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for
7、 this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error
8、or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JULY 8, 2015 UL 1034 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 8, 2015 UL 1034 tr2 No Text on This PageUL COPYRIGHTED
9、MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 18, 2011 (Title Page Reprinted: July 8, 2015) 1 UL 1034 Standard for Burglary-Resistant Electric Locking Mechanisms First Edition July, 1974 Second Edition September, 1980 Third Edition September, 1987 Fo
10、urth Edition July, 1994 Fifth Edition February, 2000 Sixth Edition May 18, 2011 This ANSI/UL Standard for Safety consists of the Sixth Edition including revisions through July 8, 2015. The most recent designation of ANSI/UL 1034 as an American National Standard (ANSI) occurred on July 8, 2015. ANSI
11、approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. The Department of Defense (DoD) has adopted UL 1034 on July 1, 1992. The publication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comment
12、s or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electron
13、ic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1034-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
14、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 Co
15、mponents 8 3 Units of Measurement .8 4 Undated References 8 5 Glossary .8 CONSTRUCTION ASSEMBLY 6 General 9 6.1 Product assembly 9 6.2 Electrical protection 10 7 Protection of Service Personnel .13 8 Enclosures 13 8.1 General 13 8.2 Product enclosure mounting 15 8.3 Doors and covers .15 8.4 Enclosur
16、e openings 15 8.5 Screens and expanded metal 18 8.6 Cast metal 18 8.7 Sheet metal 19 8.8 Polymeric materials 21 9 Electric Shock .22 10 Corrosion Protection 22 FIELD-WIRING CONNECTIONS 11 General 22 12 Cord-Connected Products .23 13 Permanently-Connected Products .25 13.1 General .25 13.2 Field-wiri
17、ng terminals .26 13.3 Field-wiring leads .28 13.4 Polarity identication 29 14 Grounding .29 INTERNAL WIRING 15 General 30 16 Wiring Methods .31 17 Separation of Circuits .32 18 Bonding for Grounding 33 MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 3UL COPYRIGHTED MATERIAL NOT
18、 AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 19 General 36 19.1 Mounting of components 36 19.2 Insulating materials .37 19.3 Fuseholders .38 19.4 Current-carrying parts .38 20 Overcurrent Protection 38 21 Semiconductors 38 22 Switches .38 23
19、Transformers and Coils 39 SPACINGS 24 General 39 25 Components .41 PERFORMANCE ALL UNITS 26 General 41 26.1 Test units and data .41 26.2 Test samples and miscellaneous data 41 26.3 Test voltages 41 26.4 Test xture 42 27 Normal Operation Test 42 28 Input Test 43 29 Output Measurement Test .43 30 Powe
20、r-Limited Circuits .44 30.1 General .44 30.2 Maximum voltage 46 30.3 Maximum current .46 30.4 VA max (Not inherently limited circuits only) .47 31 Standby Power .47 32 Undervoltage Operation Test .47 33 Overvoltage Operation Test 47 34 Variable Ambient Test .48 35 Humidity Test 48 36 Leakage Current
21、 Tests for Cord-Connected Products .48 37 Electric Shock Current Test 52 38 Overload Test 56 38.1 General .56 38.2 Separately energized circuits 56 39 Endurance Test 57 39.1 General .57 39.2 Separately energized circuits 57 40 Jarring Test 58 41 Dielectric Voltage-Withstand Test .59 42 Temperature T
22、est .60 43 Abnormal Operation Test 63 44 Electrical Transient Tests 63 44.1 General .63 MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 44.2 Supply line transients .64 44
23、.3 Internally induced transients .64 44.4 Input/output circuit transients 64 45 Polymeric Materials Test .64F 46 Battery Replacement Test 64F 47 Strain Relief Test 64F 47.1 General 64F 47.2 Field-wiring leads .64F 48 Ignition Through Bottom-Panel Openings 65 48.1 General .65 48.2 Hot, aming oil .65
24、49 Mechanical Strength Tests for Enclosures .67 50 Special Terminal Assemblies Tests .68 50.1 General .68 50.2 Disconnection and reconnection .68 50.3 Mechanical secureness .68 50.4 Flexing test 68 50.5 Millivolt drop test .69 50.6 Temperature test .69 OUTDOOR USE EQUIPMENT 51 General 69 52 Salt Spr
25、ay Corrosion Test .69 53 Rain Test 70 54 Dust Test 74 ELECTRIC LOCKING MECHANISMS 55 Forcing Tests 74 55.1 Static and dynamic strength tests 74 55.2 Static strength test .74 55.3 Dynamic strength test .75 55.4 Torque test 76 56 Tool Manipulation Attack Test 77 57 Residual Magnetism Test 77 58 Panic
26、Hardware 77 59 Emergency Exit .78 MANUFACTURING AND PRODUCTION LINE TESTS 60 Production Line Dielectric Voltage-Withstand Test 78 61 Production Line Grounding Continuity Test .79 MARKINGS 62 General 79 63 Marking Permanency Tests 82 JULY 8, 2015 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 10
27、34 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ACCESSORY EQUIPMENT 64 General 82 65 Construction .82 66 Performance (Installation) Test .83 67 Markings .83 INSTRUCTIONS 68 Installation and Operating Instructions .83 APPENDIX A Standards
28、 for ComponentsA1 MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to the construction, performance, and operation of bur
29、glary-resistant electric locking mechanisms and their related devices, such as control units, control switches, and power supplies, and the like used to secure and release doors. 1.2 A burglary-resistant electric locking mechanism shall be rated according to the three elements used to determine its
30、maximum effectiveness: a) Static strength rating of 500 pounds-force (2224 N), 1000 pounds-force (4448 N), or 1500 pounds-force (6673 N). See 55.2.1. b) Dynamic strength rating of 33 foot-pounds-force (45 J), 50 foot-pounds-force (68 J), or 70 foot-pounds-force (95 J). See 55.3.1. c) Endurance ratin
31、g of 100,000 or 250,000 cycles. See 38.2.1. A burglary-resistant electric locking mechanism shall be rated with its maximum static strength, dynamic strength, and endurance. 1.3 A burglary-resistant electric locking mechanism is intended to be used in conjunction with an access control system or a m
32、anual-release mechanism. A burglary-resistant electric locking mechanism shall be constructed so that it either does not interfere with egress through the door or other opening cover that it is used to control, or its locking action shall be capable of being released as required by the authority hav
33、ing jurisdiction if an emergency egress is required. 1.4 These requirements do not pertain to the re-retardant classication of a door and releasing-device assembly. 1.5 The term product as used in this standard refers to all types of burglary-resistant electric locking mechanisms. 1.6 A product that
34、 contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of re or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirem
35、ents to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conict with specic requirements or provisions of this standard does not comply with this standard. Revision of requirements shal
36、l be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard. MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
37、 FROM UL 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.2 A component is not re
38、quired to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating establ
39、ished for the intended conditions of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only und
40、er those specic conditions. 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 4 Unda
41、ted References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 5 Glossary 5.1 For the purpose of this standard the following denitions apply. 5.2 CIRCUITS, ELECTRICAL a) H
42、igh-Voltage (Class 1) A circuit involving a potential of not more than 600 volts and having circuit characteristics in excess of those of a low-voltage, power-limited circuit. b) Low-Voltage A circuit involving a potential of not more than 30 volts AC rms, 42.4 volts DC or AC peak. c) Power-Limited
43、A circuit whose output is limited as specied in Power-Limited Circuits, Section 30. d) Class2Acircuit in which the voltage and power limitations are in accordance with the requirements of Table 30.1 for AC circuits and Table 30.2 for DC circuits. e) Class3Acircuit in which the voltage and power limi
44、tations are in accordance with the requirements of Table 30.1 for AC circuits and Table 30.2 for DC circuits. MAY 18, 2011 BURGLARY-RESISTANT ELECTRIC LOCKING MECHANISMS - UL 1034 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.3 CORD-CON
45、NECTED PRODUCT A product intended for connection to the power source by means of a supply cord. By the nature of its design, such a product is intended to be moved for interchange or realignment of the component of a system. 5.4 ELECTRIC LOCKING MECHANISM An electrically-operated door strike, dead-b
46、olt, or the like. 5.5 ELECTROMAGNETIC LOCK An electrically-powered lock using an electromagnet magnetically coupled to an armature to provide locking power. 5.6 LINE-VOLTAGE The voltage at any eld connected source of supply, nominally 50-60 hertz (Hz); 115, 208, or 230 volts. 5.7 PRIMARY BATTERY Any
47、 battery which, by construction, is not intended to be recharged. 5.8 SECONDARY BATTERY Any battery which, by construction, is intended to be recharged. 5.9 STANDBY CONDITION The ready-to-operate condition which exists prior to being operated to unlock. CONSTRUCTION ASSEMBLY 6 General 6.1 Product as
48、sembly 6.1.1 The product shall be factory-built as a complete assembly and shall include all the essential components necessary for its intended function when installed (used) as intended. The product may be shipped from the factory as two or more major subassemblies. See the subassembly requirement
49、 in 6.1.2. 6.1.2 If the product is not assembled by the manufacturer as a complete unit, it shall be arranged in major subassemblies. Each subassembly shall be capable of being incorporated into a nal assembly without requiring alteration, cutting, drilling, threading, welding, or similar tasks by the installer. Two or more subassemblies, which must bear a denite relationship to each other for the correct installation or operation of the product, shall be arran