1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1037 Antitheft Alarms and Devices STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT
2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Antitheft Alarms and Devices, UL 1037 Sixth Edition, Dated September 9, 2016 Summary of Topics This is the sixth edition of the Standard for Antitheft Alarms and Devices, UL 1037, including new tie
3、red performance requirements for residential security containers. The new/revised requirements are substantially in accordance with Proposal(s) on this subject dated January 16, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in
4、any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purp
5、ose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has bee
6、n advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and agains
7、t any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. SEPTEMBER 9, 2016 UL 1037 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED F
8、OR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 9, 2016 UL 1037 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 9, 2016 1 UL 1037 Standard for Antitheft Alarms and Devices First
9、Edition July, 1974 Second Edition June, 1981 Third Edition December, 1988 Fourth Edition July, 1994 Fifth Edition February, 1999 Sixth Edition September 9, 2016 This ANSI/UL Standard for Safety consists of the Sixth Edition. The most recent designation of ANSI/UL 1037 as an American National Standar
10、d (ANSI) occurred on September 9, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-L
11、ine Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain th
12、e sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 1037-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 2 No Text on This PageUL COPYRIGHTED
13、 MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 General 7 2.1 Components .7 2.2 Units of measurement .8 2.3 Undated references .8 2.4 Terminology .8 3 Glossary .8 4 Installation and Operating Instructions .9 CONSTRUCTION
14、 ALL PRODUCTS ASSEMBLY 5 General .10 5.1 Product assembly .10 5.2 Electrical protection 10 6 Protection of Service Personnel .15 7 Enclosures 15 7.1 General 15 7.2 Doors and covers .17 7.3 Enclosure openings 17 7.4 Screens and expanded metal .19 7.5 Cast metal 19 7.6 Sheet metal 20 7.7 Product enclo
15、sure mounting 23 7.8 Polymeric materials 23 8 Electric Shock .23 9 Corrosion Protection .24 FIELD WIRING CONNECTIONS 10 General 24 11 Cord Connected Products .25 12 Permanently Connected Products .26 12.1 General .26 12.2 Field wiring terminals .27 12.3 Field wiring leads .29 12.4 Polarity identicat
16、ion 30 13 Grounding .30 INTERNAL WIRING 14 General 31 15 Wiring Methods .32 16 Separation of Circuits .33 17 Bonding for Grounding 34 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL C
17、OMPONENTS, ELECTRICAL 18 General 37 18.1 Mounting of components 37 18.2 Insulating materials .38 18.3 Fuseholders .39 18.4 Current-carrying parts .39 18.5 Power on indicator .39 19 Overcurrent Protection 39 20 Semiconductors 39 21 Switches .39 22 Transformers and Coils 40 SPACINGS 23 General 40 24 C
18、omponents .43 PERFORMANCE ALL PRODUCTS 25 General 43 25.1 Test units and data .43 25.2 Test samples and miscellaneous data 44 25.3 Test voltages 44 26 Normal Operation Test 44 27 Input Test 45 28 Output Measurement Test .45 29 Power-Limited Circuits .46 29.1 General .46 29.2 Maximum voltage 48 29.3
19、Maximum current .48 29.4 VA max (Not inherently limited circuits only) .49 30 Electrical Supervision Test .49 31 Undervoltage Operation Test .49 32 Overvoltage Operation Test 50 33 Variable Ambient Test .50 34 Humidity Test 50 35 Electric Shock Current Test 50 36 Leakage Current Tests for Cord-Conne
20、cted Products .54 37 Overload Test 57 37.1 General .57 37.2 Separately energized circuits 57 38 Endurance Test 58 38.1 General .58 38.2 Separately energized circuits 58 39 Jarring Test 58 40 Road Shock and Vibration Tests 59 41 Dielectric Voltage-Withstand Test .60 42 Temperature Test .61 43 Abnorma
21、l Operation Test 64 44 Electrical Transient Tests 65 44.1 General .65 44.2 Supply line transients .65 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 44.3 Internally induced transient
22、s .65 44.4 Input/output circuit transients 66 45 AC Induction Test .67 46 Polymeric Materials Test .68 47 Battery Replacement Test .68 48 Drop Test 68 49 Strain Relief Test .68 49.1 Supply cord .68 49.2 Field-wiring leads .69 50 Ignition Through Bottom-Panel Openings Tests .69 50.1 General .69 50.2
23、Hot, aming oil .69 51 Mechanical Strength Tests for Enclosures .70 52 Special Terminal Assemblies Tests .70 52.1 General .70 52.2 Disconnection and reconnection .71 52.3 Mechanical secureness .71 52.4 Flexing test 71 52.5 Millivolt drop test .71 52.6 Temperature test .72 53 Attack Test .72 54 Reside
24、ntial Security Container 72 54.1 Locks .72 54.2 Attack test Attack level I .73 54.3 Attack test Attack level II 74 54.4 Attack test Attack level III 74 MANUFACTURING AND PRODUCTION TESTS ALL HIGH-VOLTAGE PRODUCTS 55 General 75 56 Production Line Dielectric Voltage-Withstand Test 75 57 Production Lin
25、e Grounding Continuity Test for High-Voltage, Cord-Connected Products .76 MARKINGS ALL PRODUCTS 58 Details .76 59 Marking Permanency Tests 79 OUTDOOR USE EQUIPMENT ASSEMBLY 60 General 79 61 Construction .79 61.1 General .79 61.2 Corrosion protection 80 62 Field-Wiring Connections 82 63 Internal Wiri
26、ng 82 64 Components, Electrical Insulating Material .84 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 65 Rain Test 84 66 Dust Test 87 67 Variable Ambient Test .87 68 Met
27、allic Coating Thickness Test 87 69 Corrosion Tests 89 69.1 General .89 69.2 Salt spray (fog) 89 69.3 Moist hydrogen sulde (H 2 S) air mixture 90 69.4 Moist carbon dioxide (CO 2 )-sulfur dioxide (SO 2 )-air mixture .90 70 Ultraviolet Light and Water Exposure Test .90 71 Accelerated Aging Tests For Ga
28、skets, Sealing Compounds, and Adhesives .91 MARKINGS 72 Details .92 ACCESSORY EQUIPMENT 73 General 93 74 Construction .93 75 Performance (Installation) Test .94 76 Markings .94 APPENDIX A Standards for ComponentsA1 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 6UL COPYRIGHTED MATERIAL NOT
29、 AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to the construction, performance, and operation of equipment intended to provide antitheft protection. 1.2 An antitheft alarm is intended to give both audible and visible
30、 signals or only an audible signal if theft of protected property is attempted. 1.3 An antitheft device is intended to protect property by signicantly limiting the mobility or portability of the property. 1.4 Equipment intended to provide a degree of re resistance is additionally covered under the r
31、equirements of the Standard for Tests for Fire Resistance of Record Protection Equipment, UL 72. 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standard
32、s covering components generally used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is supers
33、eded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only u
34、nder limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM
35、UL 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.2.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 2.3 Undated references 2.
36、3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 2.4 Terminology 2.4.1 The term product as used in this standard refers to all types of antitheft alarms and devices. 3 Glos
37、sary 3.1 For the purpose of this standard the following denitions apply. 3.2 CIRCUITS, ELECTRICAL a) High-Voltage (Class 1) A circuit involving a potential of not more than 600 volts and having circuit characteristics in excess of those of a low-voltage power-limited circuit. b) Low-Voltage A circui
38、t involving a potential of not more than 30 volts alternating current (AC) rms, 42.4 volts peak or direct current (DC). c) Power Limited A circuit whose output is limited as specied in Power-Limited Circuits, Section 29. d) Class2Acircuit in which the voltage and power limitations are in accordance
39、with the requirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits. e) Class3Acircuit in which the voltage and power limitations are in accordance with the requirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits. 3.3 CORD-CONNECTED UNIT A unit intended for connectio
40、n to the power source by means of a supply cord. Such a unit is intended to be moved for reasons of interchange or realignment of the units of a system. 3.4 LINE VOLTAGE The voltage at any eld connected source of supply, nominally 50 60 hertz (Hz), and either 115, 208, or 230 volts. 3.5 NORMAL STAND
41、BY CONDITION The ready-to-operate condition of the product existing prior to its being tripped or operated by theft attempt. SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3.6 PERMAN
42、ENT SECURITY CONTAINER A security container that weighs more than 750 pounds or is to be xed to a surface that is not intended to be moved. 3.7 PORTABLE SECURITY CONTAINER A security container that is easily carried or conveyed by hand and is not mounted to a permanent surface. 3.8 PRIMARY BATTERY A
43、 battery that by construction is not intended to be recharged. 3.9 RESIDENTIAL SECURITY CONTAINER A container intended to be used in a residence to provide moderate protection to items (such as guns, jewelry and other valuables) against burglary or theft. 3.10 SAFETY CIRCUIT Any primary or secondary
44、 circuit that is relied upon to reduce the risk of re, electric shock, or unintentional contact with moving parts that may cause injury to persons (for example, an interlock circuit). 3.11 SECONDARY BATTERY A battery that by construction is intended to be recharged. 4 Installation and Operating Inst
45、ructions 4.1 A copy of: a) The installation and operating instructions intended to accompany each product or component as produced, b) The related schematic wiring diagrams, and c) The installation drawings is to be furnished with the sample submitted for investigation to be used as a guide in the e
46、xamination and test of the product or component. For this purpose, a nal printed edition is not required. 4.2 The instructions and drawings shall include at least the following: a) Typical installation drawing layouts and complete representative installation wiring diagrams for the product indicatin
47、g recommended locations and wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70. Locations where installations are not recommended shall also be included. b) Concise description of the operation, testing, and maintenance procedures for the product(s), and recom
48、mended testing frequency (that shall be at least once a year). c) Identication of replacement parts, such as lamps or batteries, by a part number, manufacturers model number, or other means that have been determined to be equivalent. d) A description of the conditions that might be expected to resul
49、t in false alarms or impaired operation of the product. e) A description of any features provided to reduce the risk of re, electric shock, or injury to persons and a warning against bypassing such features. SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 9UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4.3 The instructions may be incorporated on the inside of the product, on a separate sheet