UL 1240 CRD-2017 UL Standard for Safety Electric Commercial Clothes-Drying Equipment - Section Paragraph Reference Table 20A 2 Subject Clarification of Endurance Cycles for Contro.pdf

上传人:rimleave225 文档编号:1067386 上传时间:2019-04-02 格式:PDF 页数:2 大小:27.98KB
下载 相关 举报
UL 1240 CRD-2017 UL Standard for Safety Electric Commercial Clothes-Drying Equipment - Section  Paragraph Reference Table 20A 2 Subject Clarification of Endurance Cycles for Contro.pdf_第1页
第1页 / 共2页
UL 1240 CRD-2017 UL Standard for Safety Electric Commercial Clothes-Drying Equipment - Section  Paragraph Reference Table 20A 2 Subject Clarification of Endurance Cycles for Contro.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): KMEXStandard Number: UL 1240Standard Title: Standard for Electric Commercial Clothes-Drying EquipmentEdition Date: October 4, 2005Edition Number: 4Section / Paragraph Reference: Table 20A.2Subject: Cl

3、arification of Endurance Cycles for Control DevicesDECISION:20A.3.4 Controls that manage a SCF and that does not rely on software shall comply with the standardsspecified in 20A.3.2 except for Controls Using Software, H.11.12, in the Standard for Automatic ElectricalControls - Part 1: General Requir

4、ements, UL 60730-1. If software is relied upon to perform the protectivecontrol function, it shall be considered Software Class B as indicated in Table 20A.2.Table 20A.2Protective control correlation table(See 20A.3)Information Protective control requirementFMEA Conduct a failure-mode and effect ana

5、lysis (FMEA) identifyingcomponent failures which may result in a risk of fire, electricshock or injury and confirming the protective function continuesto operate as intended.Operating ambient Determined in accordance with Section 36, Temperature Test,of the applianceEndurance testing for electromech

6、anical devices a) 6, 000 cycles for controls as indicated in 20A.5, 20A.6,20A.7, and for manual, non-self-resetting temperature-limitingdevices (see 38.6), and other manual, non-self-resettingprotective controlsb) 100,000 cycles, for automatic, self-resetting temperature-limiting controls, combinati

7、on temperature-limiting andregulating controls, and other automatic, self-resettingprotective controls (see 38.6)Overvoltage category Overvoltage Category IIPollution degree See 24A.4Radio-frequency electromagnetic field immunity to conducteddisturbancesTest Level 3Radio-frequency electromagnetic fi

8、eld immunity to radiatedelectromagnetic fieldsField strength of 3 V/mFast transient bursts Test Level 3 applied for 1 minute in each polaritySurge immunity Installation Class 3Electrostatic discharge Severity Level 3Thermal cycling for electronic devices 14 days, Assumed temperature range: 10.0 +2 C

9、 to theoperating ambientSoftware class Software Class B (See 20A.3.4)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULRATIONALE FOR DECISION:This Certification Requirement Decision is intended to clarify the endurance cycles for operating andpr

10、otective control devices, and documents present practice in the application of these requirements.Copyright 2017 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they

11、will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not b

12、e responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 1240 -2-

展开阅读全文
相关资源
猜你喜欢
  • ITU-T G 995 2-2015 Enhanced common mode limits and measurement methods for customer premises equipment operating on copper pairs (Study Group 15)《在库珀对上为客户设备操作的增强共模限制和测量方法》.pdf ITU-T G 995 2-2015 Enhanced common mode limits and measurement methods for customer premises equipment operating on copper pairs (Study Group 15)《在库珀对上为客户设备操作的增强共模限制和测量方法》.pdf
  • ITU-T G 9954-2007 Home networking transceivers C Enhanced physical media access and link layer specifications (Study Group 15)《家庭网络收发器 增强物理、媒体接入和链路层规范研究组15》.pdf ITU-T G 9954-2007 Home networking transceivers C Enhanced physical media access and link layer specifications (Study Group 15)《家庭网络收发器 增强物理、媒体接入和链路层规范研究组15》.pdf
  • ITU-T G 9958-2018 Generic architecture of home networks for energy management (Study Group 15).pdf ITU-T G 9958-2018 Generic architecture of home networks for energy management (Study Group 15).pdf
  • ITU-T G 9959-2015 Short range narrow-band digital radiocommunication transceivers - PHY MAC SAR and LLC layer specifications (Study Group 15)《短距离窄式数字无线通信收发器的物理层 模拟分量复用 合成孔径雷达 液面控制层.pdf ITU-T G 9959-2015 Short range narrow-band digital radiocommunication transceivers - PHY MAC SAR and LLC layer specifications (Study Group 15)《短距离窄式数字无线通信收发器的物理层 模拟分量复用 合成孔径雷达 液面控制层.pdf
  • ITU-T G 996 1 AMD 1 SPANISH-2003 Test procedures for digital subscriber line (DSL) transceivers Amendment 1 New Annex B《数字用户线路(DSL)收发器的试验程序 1号修正案 新附录B 系列G 传输系统和媒体数字系统和网络 数字段和有线数字系统.pdf ITU-T G 996 1 AMD 1 SPANISH-2003 Test procedures for digital subscriber line (DSL) transceivers Amendment 1 New Annex B《数字用户线路(DSL)收发器的试验程序 1号修正案 新附录B 系列G 传输系统和媒体数字系统和网络 数字段和有线数字系统.pdf
  • ITU-T G 996 1 AMD 1-2003 Test procedures for digital subscriber line (DSL) transceivers Amendment 1 New Annex B SERIES G TRANSMISSION SYSTEMS AND MEDIA DIGITAL SYSTEMS AND NETWORKSc.pdf ITU-T G 996 1 AMD 1-2003 Test procedures for digital subscriber line (DSL) transceivers Amendment 1 New Annex B SERIES G TRANSMISSION SYSTEMS AND MEDIA DIGITAL SYSTEMS AND NETWORKSc.pdf
  • ITU-T G 996 1 FRENCH-2001 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)的测试程序 收发器 G系列 传动系统和媒体数字系统 网络数字节段和数字线路系统 入网 15号研究组》.pdf ITU-T G 996 1 FRENCH-2001 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)的测试程序 收发器 G系列 传动系统和媒体数字系统 网络数字节段和数字线路系统 入网 15号研究组》.pdf
  • ITU-T G 996 1 NOTE FRENCH-2003 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)收发器的试验程序》.pdf ITU-T G 996 1 NOTE FRENCH-2003 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)收发器的试验程序》.pdf
  • ITU-T G 996 1 NOTE SPANISH-2003 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)收发器的试验程序》.pdf ITU-T G 996 1 NOTE SPANISH-2003 Test procedures for digital subscriber line (DSL) transceivers《数字用户线路(DSL)收发器的试验程序》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1