UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf

上传人:dealItalian200 文档编号:1067632 上传时间:2019-04-02 格式:PDF 页数:120 大小:2.56MB
下载 相关 举报
UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf_第1页
第1页 / 共120页
UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf_第2页
第2页 / 共120页
UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf_第3页
第3页 / 共120页
UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf_第4页
第4页 / 共120页
UL 1699-2006 UL Standard for Safety Arc-Fault Circuit-Interrupters (Second Edition Reprint with Revisions Through and Including November 08 2013)《安全电弧故障断路器的UL标准 第2版》.pdf_第5页
第5页 / 共120页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1699 Arc-Fault Circuit-InterruptersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE

2、R REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Arc-Fault Circuit-Interrupters, UL 1699 Second Edition, Dated April 7, 2006 SUMMARY OF TOPICS This revision of ANSI/UL 1699 includes a Clarication of Requirements for Programmable Components. Text that has been chan

3、ged in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed require

4、ment becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated August 16, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical p

5、hotocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any spec

6、ial, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In

7、 no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim,

8、or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or ot

9、her elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. NOVEMBER

10、 8, 2013 UL 1699 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 UL 1699 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 7, 2006 (Ti

11、tle Page Reprinted: November 8, 2013) 1 UL 1699 Standard for Arc-Fault Circuit-Interrupters First Edition February, 1999 Second Edition April 7, 2006 This ANSI/UL Standard for Safety consists of the Second Edition including revisions through November 8, 2013. The most recent designation of ANSI/UL 1

12、699 as an American National Standard (ANSI) occurred on November 5, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Pr

13、oposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ow

14、nerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 1699-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 8, 2013 ARC-FAULT CIRC

15、UIT-INTERRUPTERS - UL 1699 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Glossary .8 3 Components 9 4 Units of Measurement 10 5 Undated References .10 CONSTRUCTION ALL DEVICES 6 Gene

16、ral .10 7 Accessibility of Energized Parts 10 8 Corrosion Protection .12 9 Current Carrying Parts 12 10 Internal Wiring 12 11 Insulation 12 12 Spacings 12 13 Operating Mechanism .14 14 Programmable Components .14 15 Test Circuit 15 BRANCH/FEEDER ARC-FAULT CIRCUIT-INTERRUPTER 16 General 16 17 Termina

17、ls 16 17.1 General .16 17.2 Terminal leads .16 17.3 Wire binding screw terminals 16 17.4 Pressure wire terminals .17 18 Enclosure 17 19 Grounding .17 OUTLET CIRCUIT ARC-FAULT CIRCUIT-INTERRUPTER 20 General 17 21 Terminals 18 22 Housings 18 23 Grounding .18 PORTABLE ARC-FAULT CIRCUIT-INTERRUPTER 24 G

18、eneral 18 25 Plugs/Receptacles 18 26 Cords .19 27 Direct Plug-In 19 28 Grounding .23 29 Enclosures .23 NOVEMBER 8, 2013 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CORD ARC-FAULT CIRCUIT-INTERRUP

19、TERS 30 General 23 31 Plugs/Receptacles 23 32 Grounding .23 33 Enclosures .24 PERFORMANCE 34 General 24 35 Drop and Impact Tests 26 35.1 General .26 35.2 Impact test .26A 35.3 Drop test 27 36 Humidity Conditioning .27 37 Leakage Current Measurement .27 38 Voltage Surge Test .29 38.1 General .29 38.2

20、 Unwanted tripping test (Ring wave) .29 38.3 Surge immunity test (Combination wave) 32 39 Environmental Test Sequence 33 40 Arc Fault Detection Tests 34 40.1 General .34 40.2 Carbonized path arc ignition test .34 40.3 Carbonized path arc interruption test .38 40.4 Carbonized path arc clearing time t

21、est 40 40.5 Point contact arc test .42 41 Unwanted Tripping Tests 43 41.1 General .43 41.2 Loading condition I inrush current 43 41.3 Loading condition II normal operation arcing .43 41.4 Loading condition III non-sinusoidal waveform .44 41.5 Loading condition IV cross talk .45 41.6 Loading conditio

22、n V multiple load .45 41.7 Loading condition VI lamp burnout 45 42 Operation Inhibition Tests 46 42.1 General .46 42.2 Masking the signal to operate 51 42.3 EMI lter 53 42.4 Line impedance 55 43 Dielectric Voltage-Withstand Test .57 44 Resistance to Environmental Noise Test .57 44.1 General .57 44.2

23、 Electrostatic discharge immunity .58 44.3 Radiated electromagnetic eld immunity 58 44.4 Electrical fast transient immunity .58 44.5 Voltage surge 59 44.6 Immunity to conducted disturbances, induced by RF elds 59 44.7 Voltage dips, short interruptions and voltage variations immunity .59 45 Normal Te

24、mperature Test 60 46 Overvoltage Test .61 47 Overload .61 48 Endurance Test 62 AUGUST 29, 2008 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 49 Abnormal Operations Test .63 50 Surge Current Test .6

25、4 50.1 General .64 50.2 Mounting and installation 64 50.3 Surge parameters 64 50.4 Surge polarity 65 51 Abnormal Overvoltage Tests .65 51.1 General .65 51.2 Full phase voltage high current abnormal overvoltage test .66 51.3 Limited current abnormal overvoltage test .68 52 Short Circuit Current Test

26、69 53 Terminal Lead Strain-Relief Test 71 54 Power-Supply Cord Strain-Relief Test .71 55 Mechanical Tests .71 56 Crushing Test 72 57 Dust Test 72 58 Permanence of Markings 72 59 Reverse Line Load Miswire Test 73 60 Supplemental Voltage Surge Immunity Test 73 60.1 General .73 60.2 Surge immunity test

27、 (combination wave) 74 RATINGS 61 General 75 MARKINGS 62 General 75 63 Terminations .76 64 Branch/Feeder Arc-Fault Circuit-Interrupter 77 64A Combination Arc-Fault Circuit-Interrupter .77 65 Outlet Circuit Arc-Fault Circuit-Interrupter 77 66 Portable and Cord Arc-Fault Circuit-Interrupters 77 INSTRU

28、CTIONS 67 Installation Instructions/Owners Manual .78 SUPPLEMENT SA - AFCIs RATED 120/240 V INTRODUCTION SA1 Scope SA1 CONSTRUCTION SA2 Spacings .SA1 SA3 Operation .SA1 FEBRUARY 28, 2007 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DIST

29、RIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE SA4 General SA1 SA5 Leakage Current Measurement SA2 SA6 Voltage Surge Test SA2 SA7 Carbonized Path Arc Ignition Test .SA3 SA8 Carbonized Path Arc Interruption Test SA5 SA9 Carbonized Path Arc Clearing Time Test .SA7 SA10 Point Contact Arc Test SA7 SA11

30、 Unwanted Tripping Tests SA7 SA11.1 Loading condition I inrush current SA7 SA11.2 Loading condition II normal operation arcing .SA7 SA11.3 Loading condition IV cross talk .SA8 SA12 Operation Inhibition Tests .SA8 SA12.1 General .SA8 SA12.2 Masking the signal to operate .SA9 SA12.3 Short circuit curr

31、ent test .SA11 SA13 Ratings .SA11 SUPPLEMENT SB - LEAKAGE-CURRENT DETECTOR-INTERRUPTERS (LCDIs) INTRODUCTION SB1 Scope SB1 SB2 Glossary SB1 CONSTRUCTION SB3 General SB1 SB3A Cords .SB2 SB4 Spacings SB2A SB5 Test Circuit SB2A PERFORMANCE SB6 General .SB2A SB6A LCDI Trip Threshold Test SB2B SB6B LCDI

32、Supervisory Circuit Test SB2B SB7 Arc Fault Detection Tests .SB3 SB7.1 Carbonized path arc clearing time test .SB3 SB7.2 Point contact arc test SB3 SB8 Unwanted Tripping Tests .SB3 SB9 Operation Inhibition Tests .SB4 SB9.1 Masking the signal to operate SB4 SB10 Resistance to Environmental Noise Test

33、 SB5 SB10.1 General .SB5 SB11 Supplemental Voltage Surge Immunity Test .SB6 SB11.1 Surge immunity test (combination wave) SB6 FEBRUARY 28, 2007 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL RATINGS

34、 SB12 General .SB6 FEBRUARY 28, 2007 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 6AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 28, 2007 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 6B No Text on This PageUL COPYRIGHTED MATERIAL NOT AUT

35、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARKINGS SB13 General .SB6 APPENDIX A Standards for ComponentsA1 APRIL 7, 2006 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM

36、 UL INTRODUCTION 1 Scope 1.1 The requirements of this Standard cover arc-fault circuit-interrupters (AFCIs) of the branch/feeder, outlet circuit, portable, and cord type intended for use in dwelling units. These devices are intended to mitigate the effects of arcing faults that may pose a risk of re

37、 ignition under certain conditions if the arcing persists. 1.2 AFCIs have a maximum rating of 20 A and are intended for use in 120-V ac, 60-HZ circuits. Cord AFCIs are rated up to 30 A. 1.3 These devices are not intended to detect glowing connections. 1.4 In these requirements the term device is use

38、d generically to apply to all of the devices covered by these requirements and is modied when the requirement does not apply to all types. 1.5 An AFCI that is also intended to perform other functions, such as overcurrent protection, ground-fault circuit-interruption, surge suppression, any other sim

39、ilar functions, or any combination thereof, shall comply additionally with the requirements of the applicable Standard or Standards that cover devices that provide those functions. 1.6 This standard contains a supplement covering the requirements for Leakage-Current Detector-Interrupters. 2 Glossary

40、 2.1 For the purposes of this Standard, the following denitions apply. 2.2 ARCING A luminous discharge of electricity across an insulating medium, usually accompanied by the partial volatilization of the electrodes. 2.3 ARCING FAULT An unintentional arcing condition in a circuit. 2.4 ARC-FAULT CIRCU

41、IT-INTERRUPTER (AFCI) A device intended to mitigate the effects of arcing faults by functioning to deenergize the circuit when an arc-fault is detected. 2.5 BRANCH/FEEDER ARC-FAULT CIRCUIT-INTERRUPTER A device intended to be installed at the origin of a branch circuit or feeder, such as at a panelbo

42、ard. It is intended to provide protection of the branch circuit wiring, feeder wiring, or both, against unwanted effects of arcing. This device also provides limited protection to branch circuit extension wiring. It may be a circuit-breaker type device or a device in its own enclosure mounted at or

43、near a panelboard. 2.6 CARBONIZED PATH A conductive carbon path formed through or over the surface of a normally insulating material. 2.7 COMBINATION ARC-FAULT CIRCUIT-INTERRUPTER An AFCI which complies with the requirements for both branch/feeder and outlet circuit AFCIs. It is intended to protect

44、downstream branch circuit wiring and cord sets and power-supply cords. APRIL 7, 2006 ARC-FAULT CIRCUIT-INTERRUPTERS - UL 1699 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.8 CORD ARC-FAULT CIRCUIT-INTERRUPTER A plug-in device intended t

45、o be connected to a receptacle outlet. It is intended to provide protection to the power-supply cord connected to it against the unwanted effects of arcing. The cord may be integral to the device. The device has no additional outlets. 2.8.1 MICROELECTRONICS Monolithic, hybrid, or module circuits, wh

46、ere the internal circuit connections are not accessible exclusive of provided external connection pins or pads. The circuits are capable of functioning in the analogue mode, digital mode, or a combination of the two modes. Examples of microelectronics include: ASICs, ROMs, RAMs, PROMs, EPROMs, PALs,

47、 and PLDs. See 2.11.1. 2.8.1 added November 8, 2013 2.9 OPERATION INHIBITION Denotes the concealment of an arcing fault by the normal operation of certain circuit components. 2.10 OUTLET CIRCUIT ARC-FAULT CIRCUIT-INTERRUPTER A device intended to be installed at a branch circuit outlet, such as at an

48、 outlet box. It is intended to provide protection of cord sets and power-supply cords connected to it (when provided with receptacle outlets) against the unwanted effects of arcing. This device may provide feed-through protection of the cord sets and power-supply cords connected to downstream recept

49、acles. 2.11 PORTABLE ARC-FAULT CIRCUIT-INTERRUPTER A plug-in device intended to be connected to a receptacle outlet and provided with one or more outlets. It is intended to provide protection to connected cord sets and power-supply cords against the unwanted effects of arcing. 2.11.1 PROGRAMMABLE COMPONENT Any microelectronic hardware that can be programmed in the design center, the factory, or in the eld. Here the term programmable is taken to be any manner in which o

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1