UL 183 CRD-2015 UL Standard for Safety Manufactured Wiring Systems - Section Paragraph Reference 15 6 7 1 Exception No 2 Subject MC-PCS cables with non Class 2 power conductors (E.pdf

上传人:terrorscript155 文档编号:1067700 上传时间:2019-04-02 格式:PDF 页数:2 大小:15.63KB
下载 相关 举报
UL 183 CRD-2015 UL Standard for Safety Manufactured Wiring Systems - Section  Paragraph Reference 15 6 7 1 Exception No 2 Subject MC-PCS cables with non Class 2 power conductors (E.pdf_第1页
第1页 / 共2页
UL 183 CRD-2015 UL Standard for Safety Manufactured Wiring Systems - Section  Paragraph Reference 15 6 7 1 Exception No 2 Subject MC-PCS cables with non Class 2 power conductors (E.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): QQVXStandard Number: UL 183Standard Title: Standard for Manufactured Wiring SystemsEdition Date: September 22, 2009Edition Number: 4Section / Paragraph Refer

3、ence: 15.6, 7.1 Exception No. 2Subject: MC-PCS cables with non Class 2 power conductors.DECISION:15.6 Class 2 or 3 powered conductors shall not be run in AC, MC cables, flexible metal conduit or cordswith non Class 2 or 3 powered conductors. Class 2 or 3 powered conductors may be run in MC-PCScables

4、 with non Class 2 or 3 powered conductors.7.1 Exception No. 2: Conductors for use in remote control, signaling, or communications circuits may besmaller than 12 AWG. Class 2 or 3 powered conductors may be run in MC-PCS cables with non Class 2or 3 powered conductors.RATIONALE FOR DECISION:The rationa

5、le for the revision included with the December 5, 2014 Subject 183 proposal to add a newClause 15.6 was as follows:“To address the issue of Class 2 and 3 circuit conductors being placed within the same raceway (AC, MC,FMC or S cord) as the electric light and power conductors clause 15.6 is proposed.

6、 Refer to NEC Article725.136(A) of the National Electrical Code, NFPA 70.”At the time that the Subject 183 proposal was issued, there was a Subject 1569 (MC Cable) CRD in affectthat permitted Class 2 and 3 circuit conductors to be placed within the same cable as the electric light andpower conductor

7、s. The cable complies with NEC Article 725.136(I) which permits Class 2 and 3 circuitconductors to be placed within the same cable as the electric light and power conductors where the Class2 and Class 3 conductors are separated from electric light and power conductors within the cable by ajacket ove

8、r the Class 2 and 3 conductors. The Cable is designated by UL 1569 as Type MC-PCS cable.The rationale for the CRD and eventual proposal is that Type MC-PCS cable is listed and complies withNEC Article 725.136(I) which permits Class 2 and 3 circuit conductors to be placed within the same cableas the

9、electric light and power conductors where the Class 2 and Class 3 conductors are separated fromelectric light and power conductors within the cable by a jacket over the Class 2 and 3 conductors.Copyright 2015 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its object

10、ives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. T

11、hey do not represent formal interpretations of thestandard under American National Standards Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU

12、RTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULany obligation or liability for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 183 -2-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 14902-2005 Ambient air quality - Standard method for the measurement of Pb Cd As and Ni in the PM10 fraction of suspended particulate matter English version of DIN EN 14902《.pdf DIN EN 14902-2005 Ambient air quality - Standard method for the measurement of Pb Cd As and Ni in the PM10 fraction of suspended particulate matter English version of DIN EN 14902《.pdf
  • DIN EN 14904-2006 Surfaces for sports areas - Indoor surfaces for multi-sports use - Specification English version of DIN EN 14904 2006-06《运动场地表面 多种运动用室外表面 规范》.pdf DIN EN 14904-2006 Surfaces for sports areas - Indoor surfaces for multi-sports use - Specification English version of DIN EN 14904 2006-06《运动场地表面 多种运动用室外表面 规范》.pdf
  • DIN EN 14906-2012 Leather - Leather for automotive - Test methods and testing parameters German version EN 14906 2012《皮革 汽车用皮革 试验方法和试验参数 德文版本EN 14906-2012》.pdf DIN EN 14906-2012 Leather - Leather for automotive - Test methods and testing parameters German version EN 14906 2012《皮革 汽车用皮革 试验方法和试验参数 德文版本EN 14906-2012》.pdf
  • DIN EN 14908-1-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 1 Protocol Stack English version EN 14908-1 20.pdf DIN EN 14908-1-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 1 Protocol Stack English version EN 14908-1 20.pdf
  • DIN EN 14908-2-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 2 Twisted Pair Communication English version E.pdf DIN EN 14908-2-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 2 Twisted Pair Communication English version E.pdf
  • DIN EN 14908-3-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 3 Power Line Channel Specification English ver.pdf DIN EN 14908-3-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 3 Power Line Channel Specification English ver.pdf
  • DIN EN 14908-4-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 4 IP Communication English version EN 14908-4 .pdf DIN EN 14908-4-2014 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 4 IP Communication English version EN 14908-4 .pdf
  • DIN EN 14908-5-2009 Open Data Communication in Building Automation Controls and Building Management Implementation Guideline - Control Network Protocol - Part 5 Implementation Engl.pdf DIN EN 14908-5-2009 Open Data Communication in Building Automation Controls and Building Management Implementation Guideline - Control Network Protocol - Part 5 Implementation Engl.pdf
  • DIN EN 14908-6-2015 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 6 Application elements English version EN 1490.pdf DIN EN 14908-6-2015 Open Data Communication in Building Automation Controls and Building Management - Control Network Protocol - Part 6 Application elements English version EN 1490.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有