1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): GPWVStandard Number: UL 507Edition Date: December 13, 1999Edition Number: 9Section / Paragraph Reference: 123.1, 135.7.1Subject: Window Fan and Outdoor Use F

3、an Grounding and GFCI RequirementsDECISION:123.1 In addition to the applicable requirements in Part 1 of this Standard, a fan intended for use in awindow shall comply with the requirements for Outdoor Use Equipment in Sections 134 - 138, and therequirements for fans Use in Windows in Sections 124 an

4、d 125. These requirements also address boxfans intended for use in windows. Also see 5.1.Exception No. 1: A fan intended for use in a window or a box fan intended for use in windows, with noparts requiring electrical continuity in accordance with 28.1.2, and having no dead metal parts likely tobecom

5、e energized, are not required to be provided with an equipment grounding conductor.Exception No. 2: A fan intended for use in a window or a box fan intended for use in windows is notrequired to be provided with a ground-fault circuit interrupter (GFCI).Exception No. 3: A fan intended for use in a wi

6、ndow or a box fan intended for use in windows shall notbe provided with the Outdoor Use Marking of 137.4.RATIONALE FOR DECISION:When the requirements for GFCI protection of outdoor use fans were proposed to UL 507, the rationaleincluded two key concepts: Older homes may not possess outdoor receptacl

7、es that are GFCI protected, and Outdoor products may be placed in puddles of water or located in close proximity to poolswhere GFCI protection is important regardless of the accessibility of dead metal parts.In parallel to the addition of paragraph 135.1.2, paragraph 123.1 was added to the requireme

8、nts forwindow fans. As paragraph 135.1.2 did not exist at the time and since window fans are not likely to beplaced in puddles of water or located in close proximity to pools, paragraph 123.1 did not intend to requireGFCI protection or to require an equipment grounding conductor for products of this

9、 type. The exceptionsto 123.1 are added to reflect this history.Copyright 2012 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recogn

10、ized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. They do not represent formal interpretations of thestandard under American National Standards Institute (ANSI) processes. UL shall

11、not be responsible toUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurany obligation or liability for damages, including consequential damag

12、es, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 507 -2-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1