1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 5A Nonmetallic Surface Raceways and FittingsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED F
2、OR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Nonmetallic Surface Raceways and Fittings, UL 5A Fourth Edition, Dated June 26, 2015 Summary of Topics New Fourth Edition of the Standard for Nonmetallic Surface Raceways and Fittings, UL 5A, which includes
3、 the following changes: clarication of “temperature equilibrium”, installation instructions referenced via the manufacturers website, and marking revisions. As noted in the Commitment for Amendments statement located on the back side of the title page, UL and CSA are committed to updating this harmo
4、nized standard jointly. The effective date for UL LLC is accessible on ULs Industry File Review website: https:/ ifr.nsf The new requirements are substantially in accordance with Proposal(s) on this subject dated September 26, 2014, January 16, 2015, and March 27, 2015. All rights reserved. No part
5、of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, includ
6、ing but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or th
7、e inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of UL
8、s Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers
9、 computer system. JUNE 26, 2015 UL 5A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 26, 2015 UL 5A tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL C
10、SA Group CSA C22.2 No. 62.1-15 Second Edition Underwriters Laboratories Inc. UL 5A Fourth Edition Nonmetallic Surface Raceways and Fittings June 26, 2015 ANSI/UL 5A-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendment
11、s This standard is issued jointly by the Canadian Standards Association (operating as “CSA Group”) and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to CSA Group or UL at anytime. Revisions to this standard will be made only aft
12、er processing according to the standards development procedures of CSA Group and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ISBN 978-1-77139-698-1 2015 CSA Group All rights reserved. No part of this
13、 publication may be reproduced in any form whatsoever without the prior permission of the publisher. This Standard is subject to review ve years from the date of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change to CSA Sta
14、ndards, please send the following information to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and relat
15、ed publications, visit CSA Groups Online Store at shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2015 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs S
16、tandards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Fourth Edition. The most recent designation of ANSI/UL 5A as an American National Standard (ANSI) occurred on June 26, 20
17、15. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Co
18、llaborative Standards Development System (CSDS) at http:/. To purchase UL Standards, visit Comm 2000 at http:/m- or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS PREFACE 5 1 Scope .7 2 Denitions 7 3 G
19、eneral 7 3.1 General requirements .7 3.2 Components .8 3.3 Units of measurement .8 3.4 Reference publications 8 3.5 Installation 10 3.6 Metal parts .10 4 Construction .10 4.1 General 10 4.2 Mounting .11 4.3 Partitions .12 4.4 Knockouts 12 4.5 Materials .13 4.6 Fittings .13 4.7 Wiring devices 13 4.8
20、Electrical continuity 14 4.9 Grounding/Bonding 14 5 Tests .14 5.1 General 14 5.2 Fixture box support 15 5.3 Receptacle secureness 16 5.4 Security of knockout and breakaway tab .16 5.5 Temperature 17 5.6 Deection under heat and load 17 5.7 Electrical resistance .20 5.8 Resistance to thermal degradati
21、on .20 5.9 Mold stress .20 5.10 Crush .21 5.11 Cold impact 21 5.12 Low temperature handling .22 5.13 Flammability .22 5.14 Flame test in cable trays FT4 (optional) .24 5.15 Hinge cycling 24 5.16 Short circuit 24 5.17 Pendant-type raceway deection .25 6 Installation Instructions .25 7 Markings 25 Ann
22、ex A (informative) A.1 Temperature test currents (for Canada only) 36 JUNE 26, 2015 CSA C22.2 NO. 62.1-15 UL 5A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Annex B (informative) B.1 Temperature test currents (for United States only) 37
23、JUNE 26, 2015 CSA C22.2 NO. 62.1-15 UL 5A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PREFACE This is the harmonized CSA Group and UL standard for Nonmetallic Surface Raceways and Fittings. It is the second edition of CSA C22.2 No. 62.1
24、, and the fourth edition of UL 5A. This edition of CSA C22.2 No. 62.1 supersedes the previous edition(s) published in 2003. This edition of UL 5A supersedes the previous edition(s) published on July 18, 2003. This harmonized standard was prepared by CSA Group and Underwriters Laboratories Inc. (UL).
25、 The efforts and support of the Technical Harmonization Subcommittee 23A SNR Working Group on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated
26、 scope of the standard. This standard was reviewed by the CSA Subcommittee ICCM05 Surface Raceway Systems, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CS
27、A Technical Committee. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Application of Standard Where reference is made to a specic number of samples to be tested, the specied number is to be considered a minimum quantity. Note: Al
28、though the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of the users of the standard to judge its suitability for their particular purpose. Level of Harmonization This standard uses the IEC format but is not based on
29、, nor is it considered equivalent to, an IEC standard. This standard is published as an equivalent standard for CSA Group and UL. An equivalent standard is a standard that is substantially the same in technical content, except as follows: Technical national differences are allowed for codes and gove
30、rnmental regulations as well as those recognized as being in accordance with NAFTA Article 905, for example, because of fundamental climatic, geographical, technological, or infrastructural factors, scientic justication, or the level of protection that the country considers appropriate. Presentation
31、 is word for word except for editorial changes. Reasons for Differences From IEC The THSC determined the safe use of electrical surface raceway and ttings is dependent on the design and performance of the raceway and cable systems with which they are intended to be installed. Signicant investigation
32、 is required to assess safety and system compatibility issues that may lead to harmonization of traditional North American electrical raceway and ttings with those presently addressed in the known IEC standards. The THSC agreed such future investigation might be facilitated by completion of harmoniz
33、ation of the North American standards for electrical surface raceway and ttings. JUNE 26, 2015 CSA C22.2 NO. 62.1-15 UL 5A 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Interpretations The interpretation by the standards development organ
34、ization of an identical or equivalent standard is based on the literal text to determine compliance with the standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has been identied, a revision is to be proposed
35、 as soon as possible to each of the standards development organizations to more accurately reect the intent. CSA Group Effective Date The effective date for CSA Group will be announced through a CSA Informs or CSA Group Certication Notice. UL Effective Date Information regarding the UL effective dat
36、e is on the transmittal notice that accompanies the UL Standard. JUNE 26, 2015 CSA C22.2 NO. 62.1-15 UL 5A 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Nonmetallic Surface Raceways and Fittings 1 Scope 1.1 These requirements cover nonmet
37、allic raceways and ttings. These products are for use as surface wiring systems in accordance with the Rules of the Canadian Electrical Code, Part 1, and NFPA 70, National Electrical Code. 1.2 Raceways that are all nonmetallic and of any thickness are intended to enclose circuits operating at potent
38、ials not exceeding 600 V between conductors. 1.3 Nonmetallic raceways with metal covers are intended to enclose circuits operating at potentials in accordance with Table 1 or Table 1A. 1.4 These requirements do not cover surface metal raceways, cable trays, or wireways. 2 Denitions 2.1 For the purpo
39、se of this Standard, the following denitions apply: ACCESSORY a part that may be added to a raceway system for a special purpose (for example, guards, hangers, retainers). FITTING, RACEWAY a part used to connect, change direction, or terminate a surface raceway (for example, a transition coupler, an
40、 end cap, a corner, a tee, an adapter, or a box) or a system specic wiring device that completes the system. FIXTURE BOX a box used for the support of a lighting xture, lampholder, or other equipment intended for similar installation. GROUNDING/BONDING CONDUCTOR a conductor that is dened in the Nati
41、onal Electrical Code (NEC) as an Equipment Grounding Conductor, and a conductor that is dened in the Canadian Electrical Code (CE Code), Part I, as a Bonding Conductor. NONMETALLIC a polymeric part. SURFACE NONMETALLIC RACEWAY a raceway for surface or suspension mounting with a nonmetallic base and
42、a nonmetallic or metal cover. SURFACE RACEWAY SYSTEM a system consisting of a surface raceway and associated ttings, which may include wiring devices and accessories. WIRING DEVICE a part of an electrical system intended to carry, provide a means of connection to, or provide control of electrical en
43、ergy within a raceway system (for example, switches or receptacles). 3 General 3.1 General requirements 3.1.1 For products intended for use in Canada, general requirements are given in CSA Standard C22.2 No. 0, General Requirements Canadian Electrical Code, Part II. JUNE 26, 2015 CSA C22.2 NO. 62.1-
44、15 UL 5A 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3.2 Components 3.2.1 A component of a product covered by this Standard shall comply with the requirements for that component. A component need not comply with a specic requirement tha
45、t: a) involves a feature or characteristic not needed in the application of that component in the product covered by this Standard, or b) is superseded by a requirement in this Standard. 3.2.2 A component shall be used in accordance with its rating established for the intended conditions of use. 3.2
46、.3 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3.3 Units of me
47、asurement 3.3.1 The values given in SI (metric) units shall be normative. Any other values given shall be for information purposes only. 3.4 Reference publications 3.4.1 Where reference is made to other publications, such reference shall be considered to refer to the latest edition and all amendment
48、s published to that edition up to the time when this Standard was approved. CSA Group Standards C22.1-12 Canadian Electrical Code, Part I C22.2 No. 0.15-01 Adhesive Labels C22.2 No. 0.17-00 Evaluation of Properties of Polymeric Materials C22.2 No. 42-10 General Use Receptacles, Attachment Plugs, and
49、 Similar Wiring Devices C22.2 No. 62-93 (R2013) Surface Raceway Systems C22.2 No. 111-10 General Use Snap Switches C22.2 No. 211.0 General Requirements and Methods of Testing for Nonmetallic Conduit JUNE 26, 2015 CSA C22.2 NO. 62.1-15 UL 5A 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standards UL 5 Surface Metal Raceways and Fittings UL 20 General-