UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf

上传人:花仙子 文档编号:1068406 上传时间:2019-04-02 格式:PDF 页数:18 大小:60.24KB
下载 相关 举报
UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf_第1页
第1页 / 共18页
UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf_第2页
第2页 / 共18页
UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf_第3页
第3页 / 共18页
UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf_第4页
第4页 / 共18页
UL 60335-2-40 (ND)-2012 National Differences For Household and Similar Electrical Appliances Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners and Dehumi.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60335-2-40Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirements forElectrical Heat Pumps, Air-Conditioners and DehumidifiersUL COPYR

2、IGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60335-2-40Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for ElectricalHeat Pumps, Air-Conditioners and DehumidifiersEdition: 1Editio

3、n Date: November 30, 2012This First edition of UL 60335-2-40 adopts the common ANCE, CSA and UL (trinational) Standardfor Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirementsfor Electrical Heat Pumps, Air-Conditioners and Dehumidifiers.This document provides a si

4、ngle listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise

5、without prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequenti

6、al, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs

7、 liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment

8、(including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright Underwriters Laboratories Inc.NOVEMBER 30, 2012NATIONAL DIFFERENCES FOR UL UL 60335-2-402UL COPYRIGHTED MATERIAL NOT AUTH

9、ORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify nat

10、ional difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of prod

11、ucts.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will n

12、ot be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the na

13、tional difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to inclu

14、de adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, r

15、eplacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.NOVEMBER 30, 2012 NATIONAL DIFFERENCES FOR UL UL 60335-2-40 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM U

16、LNational Differences1DV.1 DE Modification of Clause 1 of this Part 2 as follows:Delete the 4th paragraph of Clause 1, Scope.1DV.2 DE Modification of Clause 1 by adding NOTE 105A:NOTE 105A Consistent with Clause 1DV.1, this standard is not intended to be used to evaluate products thatemploy flammabl

17、e refrigerants. None of the flammable refrigerant related clauses apply. These include theflammability related requirements portions of Clause 7, Clause 22.113, Clause 22.114, Clause 22.115, Clause22.116, Clause 22.117, Clause 22.118, Annex BB, Annex CC, Annex DD, Annex FF, and Annex GG.2DV.1 DR Mod

18、ification of Clause 2 to add the following references:ANCE/CSA/UL 60335-1,Safety of Household and Similar Appliances Part 1: General RequirementsANSI/ASHRAE 15,Safety Standard for Refrigeration SystemsANSI/NFPA 70,National Electrical CodeANSI/NFPA 90A,Standard for the Installation of Air-Conditionin

19、g and Ventilating SystemsANSI/NFPA 90B,Standard for the Installation of Warm Air Heating and Air-Conditioning SystemsASME,Unfired Pressure Vessel CodeCAN/ULC-S102,Standard Method of Test for Surface Burning Characteristics of Building Materials andAssembliesCSA B52,Mechanical Refrigeration CodeCSA C

20、22.1,Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0,General Requirements Canadian Electrical Code, Part IIIEC 60335-2-34,Household and similar electrical appliances Safety Part 2-34: Particular requirementsfor motor-compressorsNOVEMBER 30, 2012NATIONAL DIFFERENCES FOR UL UL 60335-2-404UL COPYRI

21、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULIEC 60695-11-20,Fire hazard testing - Part 11-20: Test flames - 500 W flame test methodsISO 4892-2,Plastics Methods of exposure to laboratory light sources Part 2: Xenon-arc lampsUL 723Test for Surface Bu

22、rning Characteristics of Building MaterialsUL 60730-2-6Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Automatic Electrical Pressure Sensing Controls Including MechanicalRequirementsUL 60730-2-9Automatic Electrical Controls for Household and Similar Us

23、e; Part 2: ParticularRequirements for Temperature Sensing Controls3.127DV DE Add the following definition to Clause 3 of this Part 2:AFCI (ARC FAULT CIRCUIT INTERRUPTER) A device intended to mitigate the effects of arcing faultsby functioning to de-energize the circuit where an arc fault is detected

24、.3.128DV DE Add the following definition to Clause 3 of this Part 2:LCDI (LEAKAGE CURRENT DETECTION INTERRUPTER) A device provided in a power supply cord thatsenses leakage current flowing between or from the integral cord conductors andinterrupts the circuit at a predetermined level of leakage curr

25、ent.3.129DV DE Add the following definition to Clause 3 of this Part 2:HYDRONIC FAN COILS A fan coil unit that uses water which does not exceed 93C as the heatexchange fluid. The fan coil unit may be used for both heating and/or cooling.3.130DV DE Add the following definition to Clause 3 of this Par

26、t 2:ADD ON HEAT PUMP A pump that normally consists of an outdoor section, one or more indoorsections (without circulating fan), and related control devices.3.131DV DE Add the following definition to Clause 3 of this Part 2:EXTRA HARD USAGE CORD A cord intended for use with heavy equipment, classifie

27、d as thehighest grade in mechanical serviceability.3.132DV DE Add the following definition to Clause 3 of this Part 2:HARD USAGE CORD A cord intended for use with moderately heavy equipment, classified asthe medium grade in mechanical serviceability.3.133DV DE Add the following definition to Clause

28、3 of this Part 2:TAPPED CONTROL CIRCUIT A tapped control circuit is one that is tapped within the equipmentfrom the load side of the overcurrent device for the controlled load.NOVEMBER 30, 2012 NATIONAL DIFFERENCES FOR UL UL 60335-2-40 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION

29、 ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.134DV DE Add the following definition to Clause 3 of this Part 2:IGNITION SOURCE A current carrying device, or portion of a current carrying device, that canbe the source of arcing or hot wire glowing.5.7.1ADV D1 Add Clause 5.7.1ADV.1 to the Part 2:5.7.1AD

30、V.1 See normative Annex 101.DVAA for the specified temperature ranges.7.1DV DR Modification of Clause 7.1 to add the following dashed items after the firstdashed item after Addition: Motor ratings (FLA, Horsepower) Total input current (cord connected units) Minimum circuit ampacity (MCA) (permanentl

31、y connected equipment only) Motor compressor ratings (RLA and LRA) Rating of over current protective device (permanently connected equipmentonly) Branch circuit selection current (BCSC) (if RLA exceeds 64% of MCC) Manufacturing date or date code and location if the product is produced inmore than on

32、e location7.2DV DR Replacement of 7.2 of the Part 1 with the following:STATIONARY APPLIANCES for multiple supplies shall be marked with the substance of thefollowing placed on each point of supply entry:Warning: more than one source of electrical supply. Disconnect all sources beforeservicing.Compli

33、ance is checked by inspection.7.103DV DR Add the following to Clause 7 of the Part 2:Cord-connected units shall be marked with the following: If the marked ampere rating of the unit exceeds 50% of the rating of the branchcircuit to which it will be connected, the unit shall be marked “Use on SingleO

34、utlet Circuit Only”. This marking shall be adjacent to the cord entrance.Exception: The marking on a unit with a 15 ampere attachment plug may read: “Use on SingleOutlet Circuit or 20 Ampere Circuit”, if the marked rating of the unit does not exceed 10amperes. Statement requiring that a damaged cord

35、 be replaced with one supplied by theunit manufacture and not repaired.NOVEMBER 30, 2012NATIONAL DIFFERENCES FOR UL UL 60335-2-406UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL9DV.1 DR Modification of Clause 9 of the Part 2 to replace with t

36、he following:Clause 9DV of Part 1 is applicable.Table 3DV D2 Modification of Table 3 of the Part 2 as follows:Change maximum temperature for “Material used as insulation, other than that specifiedfor wires and windings: impregnated or varnished textile, paper or press-board” from 95Cto 90CChange max

37、imum temperature for “ polytetrafluoroethylene” from 290C to 205CAdd the temperature 50C for “points where the insulation of the wires can come intocontact with parts of the terminal block or compartment for fixed wiring, for stationaryappliances not provided with a supply cord.”Add the following Ex

38、ception to the above addition, “Exception: This limit may be exceededif the marking specified in 7.1DV.2 of ANCE/CSA/UL 60335-1 is supplied.”Add the following note: “NOTE 103A Maximum temperature for RTV silicon rubber is130C.”Replace note “a” of Table 3 with the following:aNot required for motor-co

39、mpressors thatcomply with annex AA of IEC 60335-2-34.13.2DV D1 Modification of Clause 13.2 of the Part 2 to add the following:The IEC Part 2 modification does not apply.16.2DV D1 Modification of Clause 16.2 of the Part 2 to add the following:The IEC Part 2 modification does not apply.19.14DV DR Modi

40、fication of Clause 19.14 of the Part 2 to add the following sentence:The outlet air temperatures shall not exceed 93C.20.101DV D1 Add Clauses 20.101DV.1 and 20.101DV.2 to the Part 1:20.101DV.1 A window-type room air conditioner that relies on a window for retention shallnot fall out when the lower p

41、ortion of the window is raised.20.101DV.2 The unit shall be installed as specified in the instructions provided by themanufacturer, except that any window locks or similar devices shall be removed so thatthe window can be raised. With the window raised, a horizontal force of 111 N shall beapplied to

42、 the top edge center of the indoor side of the cabinet.21.1DV D2 Add Clause 21.1DV.3 to the Part 1:21.1DV.3 A non-metallic ACCESSIBLE PART used as an enclosure for a LIVE PART shall besubjected to the mechanical strength of Clause 21.1 with an impact energy of 6,8 J.NOVEMBER 30, 2012 NATIONAL DIFFER

43、ENCES FOR UL UL 60335-2-40 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL21.101DV D1 Add Clauses 21.101DV.1 21.101DV.7 to the Part 1:21.101DV.1 A windowtype air conditioning unit shall withstand a static load of 180 kgapplied to the outer 1

44、30 cm of the outdoor portion of the unit when mounted in a windowin accordance with the instructions provided by the manufacturer.21.101DV.2 Appliances shall withstand reasonably foreseeable mechanical abuse.21.101DV.3 For equipment other than dehumidifiers, a substantially horizontal plane on the t

45、opof equipment shall be capable of sustaining a static load of 91 kg, applied in a vertical direction,in the most unfavorable location, over a 152 mm diameter circular area.21.101DV.4 For dehumidifiers, the appliance shall be positioned as intended for use shallwithstand a static load of 45 kg appli

46、ed to each of two flat metal plates simultaneously. The platesshall be 102 x 254 x 6.6 mm and should be positioned to simulate an individual sitting on theappliance.21.101DV.5 For equipment with a guard, a force of 111 N shall be applied to the guard by a 38mm diameter rod. The force shall be applie

47、d in a direction normal to the guard surface.21.101DV.6 During or following the above tests the equipment shall comply with 20.2 even withany deflection or permanent deformation that might occur. The equipment shall comply with therequirements in this standard following these tests in the as-receive

48、d condition.21.101DV.7 If electrical enclosure seal gaskets are required to comply with the tests ofClause 15, then they shall comply with Annex 101.DVJJ, Accelerated aging tests Gaskets.22.11DV D1 Modification of Clause 22.11 of the Part 1 by adding the following sentenceto the first paragraph:A co

49、ver over a fuse shall be hinged, provided with an automatic latch and secured in amanner that requires a tool for opening.22.112DV DR Add Clauses 22.112DV.1 22.112DV.17 to the Part 1:22.112DV.1 The tubing connections of dissimilar metals, such as aluminum and copper,shall be protected against moisture to minimize galvanic action.22.112DV.2 Tubing used in the construction of refrigerant-containing parts, such as anevaporator or condenser coil that is adequately protected by the inherent construction,shall comply with the strength requirem

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1