UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf

上传人:花仙子 文档编号:1068407 上传时间:2019-04-02 格式:PDF 页数:46 大小:239.11KB
下载 相关 举报
UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf_第1页
第1页 / 共46页
UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf_第2页
第2页 / 共46页
UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf_第3页
第3页 / 共46页
UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf_第4页
第4页 / 共46页
UL 60335-2-40 (ND)-2017 National Differences For Household And Similar Electrical Appliances C Safety C Part 2-40 Particular Requirements for Electrical Heat Pumps Air-Conditioners.pdf_第5页
第5页 / 共46页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForHousehold And Similar Electrical Appliances Safety Part 2-40: Particular Requirements forElectrical Heat Pumps, Air-Conditioners and DehumidifiersUL COPYRIGHTED MATERIAL N

2、OT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForHousehold And Similar Electrical Appliances Safety Part 2-40: Particular Requirements for ElectricalHeat Pumps, Air-Conditioners and DehumidifiersSecond EditionEdition Date: September 15, 2017This

3、 Second edition of UL 60335-2-40 is being adopted as an ANSI standard.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ort

4、ransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability

5、or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an auth

6、orized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnif

7、y, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2017 Underwriters Labora

8、tories Inc.SEPTEMBER 15, 2017NATIONAL DIFFERENCES FOR2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC stan

9、dard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirem

10、ents, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on thema

11、nufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national

12、regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete

13、new numbered clause, subclause, table, figure,or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modif

14、y - A modification is an altering of the existing base IEC text such as the addition,replacement or deletion of certain words or the replacement of an entire clause, subclause, table, figure,or annex of the base IEC text.SEPTEMBER 15, 2017 NATIONAL DIFFERENCES FOR 3UL COPYRIGHTED MATERIAL NOT AUTHOR

15、IZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV.1 DR Modification of the second paragraph of Clause 1 as follows:Change “250 V” to “300 V” and add the following sentence to the end of the secondparagraph “Partial units are within the scope of this Stand

16、ard.”1DV.2 D1 Modification of the 2nd paragraph of Clause 1 as follows:Change 600 V to 15 000 V.1DV.3 DE Add the following note:Note 102A: Class A2 includes class A2L.1DV.4 DR Modification of the eighth paragraph of Clause 1 as follows:Replace “ISO 5149” with ANSI/ASHRAE 15 Safety Standard for Refri

17、geration Systems(USA) and CSA B52 Mechanical Refrigeration Code (Canada).2DV DR Modification of Clause 2 to add the following references:CSA/UL 60335-1Safety of Household and Similar Appliances Part 1: General RequirementsANSI/ASHRAE 15Safety Standard for Refrigeration SystemsANSI/NFPA 70National El

18、ectrical CodeANSI/NFPA 90AStandard for the Installation of Air-Conditioning and Ventilating SystemsANSI/NFPA 90BStandard for the Installation of Warm Air Heating and Air-Conditioning SystemsASME VIIIUnfired Pressure Vessel CodeASTM B344Standard Specification for Drawn or Rolled Nickel-Chromium and N

19、ickel-Chromium-IronAlloys for Electrical Heating ElementsCAN/ULC-S102Standard Method of Test for Surface Burning Characteristics of Building Materials andAssembliesSEPTEMBER 15, 2017NATIONAL DIFFERENCES FOR4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMIS

20、SION FROM ULCSA B52Mechanical Refrigeration CodeCSA C22.1Canadian Electrical Code, Part ICAN/CSA-C22.2 No. 0General Requirements Canadian Electrical Code, Part IICSA-C22.2 No. 0.3Test methods for electrical wires and cablesCAN/CSA-C22.2 No. 0.17Evaluation of properties of polymeric materialsCSA-C22.

21、2 No. 100Motors and generatorsCSA-C22.2 No. 197PVC insulating tapeCAN/CSA-C22.2 No. 198.1Extruded insulating tubingCSA-C22.2 No. 253Medium-voltage ac contactors, controllers, and control centresCSA-C22.2 No. 274Adjustable speed drivesCAN/CSA-C22.2 No. 60335-2-34Safety of household and similar electr

22、ical appliances Part 2-34: Particular requirementsfor motor-compressorsIEC 60335-2-34,Household and similar electrical appliances Safety Part 2-34: Particular requirementsfor motor-compressorsIEC 60695-11-20,Fire hazard testing Part 11-20: Test flames 500 W flame test methodsISO 4126-1Safety devices

23、 for protection against excessive pressure Part 1: Safety valvesISO 4126-2Safety devices for protection against excessive pressure Part 2: Bursting disc safetydevicesISO 4892-2Plastics Methods of exposure to laboratory light sources Part 2: Xenon-arc lampsSEPTEMBER 15, 2017 NATIONAL DIFFERENCES FOR

24、5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL 94Standard for Tests for Flammability of Plastic Materials for Parts in Devices andAppliancesUL 224Standard for Extruded Insulating TubingUL 347Standard for Medium-Voltage AC Contactors, Cont

25、rollers, and Control CentersUL 510Standard for Polyvinyl Chloride, Polyethylene and Rubber Insulating TapeUL 723Standard for Test for Surface Burning Characteristics of Building MaterialsUL 1004-9Standard for Form Wound and Medium Voltage Rotating Electrical MachinesUL 1441Standard for Coated electr

26、ical sleevingUL 1581Reference Standard for Electrical Wires, Cables, and Flexible CordsUL 1694Standard for Tests for Flammability of Small Polymeric Component MaterialsUL 60730-2-6Automatic Electrical Controls Part 2-6: Particular Requirements for Automatic ElectricalPressure Sensing Controls Includ

27、ing Mechanical RequirementsUL 60730-2-9Standard for Automatic Electrical Controls Part 2-9: Particular Requirements forTemperature Sensing ControlsUL 61800-5-1Standard for Adjustable Speed Electrical Power Drive Systems Part 5-1: SafetyRequirements Electrical, Thermal and Energy3.127DV D1 Modificati

28、on by replacing Clause 3.127 with the following:FACTORY SEALED APPLIANCEappliance in which all refrigerating system parts have been sealed tight by welding,brazing or a similar permanent connection during the manufacturing process and does notinclude service ports.3.129DV DE Add the following defini

29、tions, 3.129DV 3.136DV to Clause 3 of this Part 2:3.129DV AFCI (ARC FAULT CIRCUIT INTERRUPTER): a device intended to mitigate the effects of arcingfaults by functioning to de-energize the circuit where an arc fault is detected.SEPTEMBER 15, 2017NATIONAL DIFFERENCES FOR6UL COPYRIGHTED MATERIAL NOT AU

30、THORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.130DV LCDI (LEAKAGE CURRENT DETECTION INTERRUPTER): a device provided in a power supply cordthat senses leakage current flowing between or from the integral cord conductors andinterrupts the circuit at a predetermined level

31、 of leakage current.3.131DV HYDRONIC FAN COILS: a fan coil unit that uses water which does not exceed 93C asthe heat exchange fluid. The fan coil unit may be used for both heating and/or cooling.3.132DV ADD ON HEAT PUMP: a heat pump that normally consists of an outdoor section, one ormore indoor sec

32、tions (without circulating fan), and related control devices.3.133DV EXTRA HARD USAGE CORD: a cord intended for use with heavy equipment, classified asthe highest grade in mechanical serviceability.3.134DV HARD USAGE CORD: a cord intended for use with moderately heavy equipment,classified as the med

33、ium grade in mechanical serviceability.3.135DV TAPPED CONTROL CIRCUIT: a tapped control circuit is one that is tapped within theequipment from the load side of the overcurrent device for the controlled load.3.136DV IGNITION SOURCE: a current carrying device, or portion of a current carrying device,t

34、hat can be the source of arcing or hot wire glowing.3.137DV D2 Add the following definition and Note to Clause 3 of this Part 2:DIRECT RELEASABLE SYSTEM: system with one degree of separation from a space.Note 1 to Entry: For the purpose of this standard, direct and indirect systems are defined with

35、respect to thepotential to leak refrigerant into a space.3.138DV D2 Add the following definition to Clause 3 of this Part 2:DIRECT SYSTEM: a direct releasable system in which a single rupture of the refrigerant circuitresults in a refrigerant release to a space, irrespective of the location of the r

36、efrigerantcircuit.3.139DV D2 Add the following definition and Note to Clause 3 of this Part 2:INDIRECT SYSTEM: system with more than one degree of separation from the space.Note 1 to Entry: For the purpose of this standard, direct and indirect systems are defined with respect to thepotential to leak

37、 refrigerant into a space.3.149DV D1 Add the following definition to Clause 3 of this Part 2:ELECTRICAL CONNECTION: the physical interface between two points in a circuit such as spadeterminals, pin terminals, micro switch contacts, relay contacts, timer contacts, crimpedconnections, and connections

38、 that are welded or soldered.5.2DV D2 Modification of Clause 5.2 in the Part 1 by adding the following:Tests of Clause 15 may be conducted on a separate sample.SEPTEMBER 15, 2017 NATIONAL DIFFERENCES FOR 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSI

39、ON FROM UL5.3DV D2 Modification of Clause 5.3 in the Part 1 by addition of the following:The test of Clauses 19.101 through 19.105DV may be run in any sequence within Clause19.5.7.1ADV D1 Add Clause 5.7.1ADV.1 to the Part 2:5.7.1ADV.1 See normative Annex 101.DVA for the minimum test conditions.5.10D

40、V D2 Modification by replacing the second sentence of Clause 5.10 of this Part 2with the following:The line length shall be not less than 5 m but may be greater than 7.5 m.7.1DV.1 DR Modification of Clause 7.1 to add the following dashed items after the firstdashed item after “Addition:” Motor ratin

41、gs (FLA, Horsepower)For motors controlled by adjustable speed drive, FLA shall be replacedwith either the motors MOC or the rated input current of the powerconversion equipment. When there is bypass utilized, it shall be the largerof the motors MOC, the rated input current to the power conversionequ

42、ipment or the full load amperes of the motor. Total input current (cord connected units) Minimum circuit ampacity (MCA) (permanently connected equipment only) Motor compressor ratings (RLA and LRA)For motor-compressors controlled by adjustable speed drive, (RLA andLRA) shall be replaced with the rat

43、ed input current of the powerconversion equipment. Rating of over current protective device (permanently connected equipmentonly) Branch circuit selection current (BCSC) (if RLA exceeds 64% of MCC) Manufacturing date or date code and location if the product is produced inmore than one location7.1DV.

44、2 DE Modification by adding the following note to Clause 7.1:Note 1DV In Canada, the equivalent French wording for the warning is as follows:AVERTISSEMENTLappareil doit tre install, utilis et entrepos dans un endroit dont la superficie du plancher est suprieure X m2(applicable uniquement aux apparei

45、ls qui ne sont pas fixes)SEPTEMBER 15, 2017NATIONAL DIFFERENCES FOR8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.1DV.3 D1 Modification of Clause 7.1 by adding the following to the seventh paragraph,regarding minimum room size X:The X in t

46、he marking shall not be required if the refrigerant charge of the appliance is lessthan or equal to m1according to Annex GG.1.1.7.1ADV D1 Addition of the following clauses to Clause 7 of this Part 2:7.1ADV.1 If the refrigerant is flammable the air conditioning equipment shall have red,Pantone Matchi

47、ng System (PMS) #185 marked service ports, pipes, hoses, and otherdevices through which the refrigerant is serviced. This colour shall be present at allservice ports and where service puncturing or otherwise creating an opening from therefrigerant circuit to the atmosphere might be expected (e.g., p

48、rocess tubes). The colourmark shall extend at least 25 mm (1 inch) from the refrigerant servicing point and shall bereplaced if removed.7.1ADV.2 If refrigerant is flammable, the markings specified in Clauses 7.1ADV.3 to7.1ADV.5 in letters at least 6.35 mm (0.25 in) high shall be permanently affixed

49、to theequipment in the location indicated.7.1ADV.3 The following markings, or the equivalent, shall be located on the outside of theproduct when flammable refrigerants are employed: “DANGER Risk Of Fire Or Explosion. Flammable Refrigerant Used. To BeRepaired Only By Trained Service Personnel. Do Not Puncture RefrigerantTubing.” “CAUTION Risk Of Fire Or Explosion. Dispose Of Properly In AccordanceWith Federal Or Local Regulations. Flammable Refrigerant Used.Note In Canada, the equivalent French wording for t