UL 60335-2-8 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-8 Particular Requirements for Shavers Hair Clippers and Similar Appliance.pdf

上传人:ownview251 文档编号:1068424 上传时间:2019-04-02 格式:PDF 页数:2 大小:27.28KB
下载 相关 举报
UL 60335-2-8 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-8 Particular Requirements for Shavers Hair Clippers and Similar Appliance.pdf_第1页
第1页 / 共2页
UL 60335-2-8 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-8 Particular Requirements for Shavers Hair Clippers and Similar Appliance.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): KEFXStandard Number: UL 60335-2-8Standard Title: Standard for Particular Requirements for Hair Clippers and ShaversEdition Date: June 25, 2018Edition Number: 6Section / Paragraph Reference: 25.1DV.1.1

3、Subject: Nonpolarized Attachment Plugs for Class II ShaversDECISION:25.1DV.1.1 DR Modification to replace 25.1DV.1.1 of the Part 1 with the following:The SUPPLY CORD of appliances incorporating a screwshell type lampholder or and of appliances, otherthan Class II shavers, incorporating a manually op

4、erated, mains connected, single-pole switch intendedfor appliance on-off operation shall be fitted with a polarized attachment plug. The switch shall beelectrically connected to a terminal or lead intended for connection to an ungrounded conductor of thesupply circuit.RATIONALE FOR DECISION:The NEC

5、includes an exception to the polarization requirements for double insulated shavers in 422.40.This was previously allowed in the 5th edition, Clause 22.104DV.5.1, and in UL 1028, so it isrepresentative of current practice.Copyright 2018 UL LLCUL LLC, in performing its functions in accordance with it

6、s objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not repr

7、esent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including c

8、onsequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSTANDARD NUMBER: UL 60335-2-8 -2-No Text on This Page

展开阅读全文
相关资源
猜你喜欢
  • SANS 60799-2007 Electrical accessories - Cord sets and interconnection cord sets《电器附件 电线组件及互连线组件》.pdf SANS 60799-2007 Electrical accessories - Cord sets and interconnection cord sets《电器附件 电线组件及互连线组件》.pdf
  • SANS 608-2007 Reference materials - General and statistical principles for certification《参考物质的认证 总则和统计原则》.pdf SANS 608-2007 Reference materials - General and statistical principles for certification《参考物质的认证 总则和统计原则》.pdf
  • SANS 6081-2008 Cleaning efficiency of low-foam laundry detergents《低泡沫洗涤剂的清洗效率》.pdf SANS 6081-2008 Cleaning efficiency of low-foam laundry detergents《低泡沫洗涤剂的清洗效率》.pdf
  • SANS 60815-1-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 1 Definitions information and general principles《在受污染环境中使用的高压绝缘.pdf SANS 60815-1-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 1 Definitions information and general principles《在受污染环境中使用的高压绝缘.pdf
  • SANS 60815-2-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 2 Ceramic and glass insulators for a c systems《在受污染环境中使用的高压绝缘子的.pdf SANS 60815-2-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 2 Ceramic and glass insulators for a c systems《在受污染环境中使用的高压绝缘子的.pdf
  • SANS 60815-3-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 3 Polymer insulators for a c systems《在受污染环境中使用的高压绝缘子的选择及尺寸 第3部分.pdf SANS 60815-3-2009 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 3 Polymer insulators for a c systems《在受污染环境中使用的高压绝缘子的选择及尺寸 第3部分.pdf
  • SANS 6083-2004 Modulus of elasticity and modulus of rupture in static bending of solid timber and glued laminated timber in structural sizes《构筑物中实心木料和多层胶合木料的静弯曲弹性模量和断裂模量》.pdf SANS 6083-2004 Modulus of elasticity and modulus of rupture in static bending of solid timber and glued laminated timber in structural sizes《构筑物中实心木料和多层胶合木料的静弯曲弹性模量和断裂模量》.pdf
  • SANS 60839-1-1-2007 Alarm systems Part 1 General requirements Section One General《报警系统 第1部分 一般规定 第一节 一般》.pdf SANS 60839-1-1-2007 Alarm systems Part 1 General requirements Section One General《报警系统 第1部分 一般规定 第一节 一般》.pdf
  • SANS 60839-1-2-2007 Alarm systems Part 1 General requirements Section Two Power units test methods and performance criteria《报警系统 第1部分 一般规定 第二节 电源单元、试验方法及性能标准》.pdf SANS 60839-1-2-2007 Alarm systems Part 1 General requirements Section Two Power units test methods and performance criteria《报警系统 第1部分 一般规定 第二节 电源单元、试验方法及性能标准》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1