1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60384-14Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specification: FixedCapacitors for Electromagnetic Interference Suppression and Connection t
2、o the Supply MainsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60384-14Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specification: Fixed Capacitorsfor Electromagnetic Interference Suppressio
3、n and Connection to the Supply MainsSecond EditionEdition Date: JULY 11, 2014The revisions to UL 60384-14 are being issued to incorporate the Amendments made to IEC60384-14, edition 4.1 dated July, 2016. Please note that the National Difference documentincorporates all of the U.S. national differenc
4、es for UL 60384-14.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, me
5、chanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be l
6、iable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the pos
7、sibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, e
8、xpense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2016 Underwriters Laboratories Inc.DECEMBER 5, 2016NATIONAL DIFFERENCES FOR
9、 UL 60384-142UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses
10、the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromis
11、e safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviation
12、s based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national dif
13、ference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, fi
14、gure,or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the
15、existing base IEC text such as the addition,replacement or deletion of certain words or the replacement of an entire clause, subclause, table, figure,or annex of the base IEC text.DECEMBER 5, 2016 NATIONAL DIFFERENCES FOR UL 60384-14 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O
16、RDISTRIBUTION WITHOUT PERMISSION FROM ULNational DifferencesFigure 9DV D2 Modification of Ct value in Figure 9 by adding alternate means with thefollowing:Ct = tank capacitor is 3 F 5 % up to Cx = 10 F. For Cx 10 F it is allowed to use areasonably higher value of Ct for the intended wave form in order to standardize the testequipment.DECEMBER 5, 2016NATIONAL DIFFERENCES FOR UL 60384-144