UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf

上传人:deputyduring120 文档编号:1068464 上传时间:2019-04-02 格式:PDF 页数:28 大小:846.17KB
下载 相关 举报
UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf_第1页
第1页 / 共28页
UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf_第2页
第2页 / 共28页
UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf_第3页
第3页 / 共28页
UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf_第4页
第4页 / 共28页
UL 60730-2-12A-2002 UL Standard for Safety Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Electrically Operated Door Locks (First Ed_1.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、UL 60730-2-1 2A ISBN 0-7629-0578-6 Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Door Locks FEBRUARY 1,2002 - UL 60730-2-12A trl Underwriters Laboratories Inc. (UL) 333 Pfingsten Road Northbrook, IL 60062-2096 UL Standard for S

2、afety for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Door Locks, UL 60730-2-12A First Edition, Dated February 1, 2002 The master for this Standard at UL?s Northbrook Office is the official document insofar as it relates to a

3、 UL service and the compliance of a product with respect to the requirements for that product and service, or if there are questions regarding the accuracy of this Standard. UL?s Standards for Safety are copyrighted by UL. Neither a printed copy of a Standard, nor the distribution diskette for a Sta

4、ndard-on-Diskette and the file for the Standard on the distribution diskette should be altered in any way. All of UL?s Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. All rights reserved. No part of this publication m

5、ay be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. Revisions of UL Standards for Safety are issued from time to time. A UL Standard for Safety is current only if it inco

6、rporates the most recently adopted revisions. UL provides this Standard ?as is? without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or fitness for any purpose. In no event will UL be liable for any special, incidental, co

7、nsequential, indirect or similar damages, including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall U

8、L?s liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. UL will attempt to answer support requests concerning electronic versions of its Standards. However, this support service is offered on a reasonable efforts basis only, and UL may not be a

9、ble to resolve every support request. UL supports the electronic versions of its Standards only if they are used under the conditions and operating systems for which it is intended. UL?s support policies may change from time-to-time without notification. UL reserves the right to change the format, p

10、resentation, file types and formats, delivery methods and formats, and the like of both its printed and electronic Standards without prior notice. Purchasers of the electronic versions of UL?s Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, l

11、iability, damage, claim, or judgement (including reasonable attorney?s fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchaser?s computer system. If a single-user version electronic Standard was purchased, one copy of this Standard ma

12、y be stored on the hard disk of a single personal computer, or on a single LAN file-server or the permanent storage device of a multiple-user computer in such a manner that this Standard may only be accessed by one user at a time and for which there is no possibility of multiple concurrent access. t

13、r2 FEBRUARY 1, 2002 - UL 60730-2-12A If a multiple-user version electronic Standard was purchased, one copy of the Standard may be stored on a single LAN file-server, or on the permanent storage device of a multiple-user computer, or on an Intranet server. The number of concurrent users shall not ex

14、ceed the number of users authorized. Electronic Standards are intended for on-line use, such as for viewing the requirements of a Standard, conducting a word search, and the like. Only one copy of the Standard may be printed from each single-user version of an electronic Standard. Only one copy of t

15、he Standard may be printed for each authorized user of a multiple-user version of an electronic Standard. Because of differences in the computer/software/printer setup used by UL and those of electronic Standards purchasers, the printed copy obtained by a purchaser may not look exactly like the on-l

16、ine screen view or the printed Standard. An employee of an organization purchasing a UL Standard can make a copy of the page or pages being viewed for their own fair and/or practical internal use. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, fig

17、ures, and/or other elements of the Standard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a “SUPERSEDED REQUIREMENTS notice. New product submi

18、ttals made prior to a specified future effective date will be judged under all of the requirements in this Standard including those requirements with a specified future effective date, unless the applicant specifically requests that the product be judged under the current requirements. However, if t

19、he applicant elects this option, it should be noted that compliance with all the requirements in this Standard will be required as a condition of continued Listing, Recognition, and Follow-Up Services after the effective date, and understanding of this should be signified in writing. It should be no

20、ted that in an effort to more closely match the IEC text, information in the following checklist related to annexes may not correlate correctly at this time with the annex identification in the annexes themselves. This information will be correct in future revision cycles. Copyright O 2002 Underwrit

21、ers Laboratories Inc. This Standard consists of pages dated as shown in the following checklist: Page Date 1-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . February 1, 2002 AI-A2 February 1,2002 FE

22、BRUARY 1,2002 1 UL 60730-2-12A Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Door Locks Prior to the first edition of UL 60730-2-12A, the requirements for the products covered by this Standard were included in UL 6

23、0730-2-12. First Edition February 1,2002 An effective date included as a note immediately following certain requirements is one established by Underwriters Laboratories Inc. Revisions of this Standard will be made by issuing revised or additional pages bearing their date of issue. A UL Standard is c

24、urrent only if it incorporates the most recently adopted revisions, all of which are itemized on the transmittal notice that accompanies the latest set of revised requirements. ISBN 0-7629-0578-6 COPYRIGHT O 1999, 2002 UNDERWRITERS LABORATORIES INC. 2 UL 60730-2-12A FEBRUARY 1,2002 No Text on This P

25、age FEBRUARY 1. 2002 UL 60730-2-12A 3 CONTENTS Preface (UL) 5 Foreword (UL) 6 NATIONAL DIFFERENCES . 7 FOREWORD 8 1 Scope IO 2 Definitions 11 2.2 Definitions of types of controls according to purpose . 11 2.3 Definitions relating to the function of controls . 11 3 General requirements 11 4 General n

26、otes on tests . 11 4.1 Conditions of test 12 5 Rating 12 6 Classification 12 6.3 According to their purpose 12 7 Information 13 8 Protection against electric shock 13 9 Provision for protective earthing . 13 1 O Terminals and TERMINATIONS 11 Constructional requirement 12 Moisture and dust resistance

27、 13 Electric strength and insulation resistance . 14 14 Heating 14 15 MANUFACTURING DEVIATION and DRIFT 14 16 Environmental stress 14 17 Endurance . 14 1 7.1.3 Test sequence and conditions 14 17.3 Thermal conditions for the tests 15 17.4 Manual and mechanical conditions for the tests 15 17.7 Over-vo

28、ltage (or, in some countries, overload) test of AUTOMATIC ACTION at accelerated rate . 15 17.8 Test of AUTOMATIC ACTION at accelerated rate 16 17.10 Over-voltage (or in some countries, overload) test of MANUAL ACTION at accelerated . 6.4 According t0 featUfeS Of AUTOMATIC ACTION . 13 18 Mechanical s

29、trength 19 Threaded parts and connections 20 CREEPAGE DISTANCES, CLEARANCES . 18 21 Resistance to heat, fire and tr 22 Resistance to corrosion 18 23 Radio interference suppression 24 Components . 18 25 Normal OPERATION 18 26 OPERATION with mains borne perturbations, magnetic, and electromagnetic dis

30、turbances 18 27 Abnormal OPERATION . 19 4 UL 60730-2-12A FEBRUARY 1,2002 28 Guidance on the use of ELECTRONIC DISCONNECTION . .I9 Figures Annexes Annex C Cotton used for mercury switch test Annex H (normative) Requirements for ELECTRONIC CONTROLS H.6.18 According to software class H. 1 1 .I2 Control

31、s using software . 19 . .I9 . 19 H.ll Constructional requirements . H.26 OPERATION with mains borne pertur H.26.4 Test of the influence of H.26.5 Test of the influence of vo network H.26.7 Test of the influence of d.c. in a.c. networks . H.26.8 1,2/50 ps - 8/20 ps volta H .26.9 Fast transient burst

32、test . H.26.6 Test of I of voltage unbalance .21 H.26.1 O Ring wave test . H .26.11 Electrostatic discharge test . .22 H.27 Abnormal OPERATION . .22 .22 H .26.12 Radiated electrornagne Annex 12.DVA - Manufacturing and Production Tests (normative) FEBRUARY 1,2002 UL 60730-2-12A 5 Preface (UL) This UL

33、 Standard 60730-2-1 2A Standard for Safety for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Door Locks, is to be used in conjunction with the third edition of UL 60730-IA. The requirements for electrically operated door locks

34、are contained in this part 2 Standard and UL 60730-IA. Requirements of this part 2 Standard, where stated, amend the requirements of UL 60730-IA. Where a particular subclause of UL 60730-IA is not mentioned in UL 60730-2-12A, the UL 60730-IA subclause applies. The text, figures and tables of IEC Pub

35、lication Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Door Locks, IEC 60730-2-12 copyright 1995, are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted m

36、aterial has been reproduced with permission from ANSI. ANSI should be contacted regarding the reproduction of any portion of the IEC material. The IEC Foreword and Introduction are not a part of the requirements of this Standard but are included for information purposes only. Copies of IEC Publicati

37、on 60730-2-12 may be purchased from ANSI, 11 West 42nd Street, New York, New York, 10036, (212) 642- 4900. Note - Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its su

38、itability for their particular purpose. 6 UL 60730-2-12A FEBRUARY 1,2002 Foreword (U L) A. This Standard contains basic requirements for products covered by Underwriters Laboratories Inc. (UL) under its Follow-Up Service for this category within the limitations given below and in the Scope section o

39、f this Standard. These requirements are based upon sound engineering principles, research, records of tests and field experience, and an appreciation of the problems of manufacture, installation, and use derived from consultation with and information obtained from manufacturers, users, inspection au

40、thorities, and others having specialized experience. They are subject to revision as further experience and investigation may show is necessary or desirable. B. The observance of the requirements of this Standard by a manufacturer is one of the conditions of the continued coverage of the manufacture

41、rs product. C. A product which complies with the text of this Standard will not necessarily be judged to comply with the Standard if, when examined and tested, it is found to have other features which impair the level of safety contemplated by these requirements. D. A product that contains features,

42、 characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain

43、the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed

44、 and adopted in conformance with the methods employed for development, revision, and implementation of this standard. E. UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. The opinion

45、s and findings of UL represent its professional judgment given with due consideration to the necessary limitations of practical operation and state of the art at the time the Standard is processed. UL shall not be responsible to anyone for the use of or reliance upon this Standard by anyone. UL shal

46、l not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Standard. F. Many tests required by the Standards of UL are inherently hazardous and adequate safeguards for personnel and prop

47、erty shall be employed in conducting such tests. FEBRUARY 1,2002 UL 60730-2-12A 7 NATIONAL DIFFERENCES GENERAL National Differences from the text of International Electrotechnical Commission (IEC) Publication 60730-2-12, Automatic Electrical Controls for Household and Similar Use; Part 2: Particular

48、 Requirements for Electrically Operated Door Locks, copyright 1995, are indicated by notations (differences) and are presented in bold text. There are five types of National Differences as noted below. The difference type is noted on the first line of the National Difference in the standard. The sta

49、ndard may not include all types of these National Differences. DR - These are National Differences based on the National Electrical Code (NEC) and other U.S. Regulatory Requirements. DI - These are National Differences which are based on basic safety principles and requirements, elimination of which would compromise safety for U.S. consumers and users of products. D2 - These are National Differences based on safety practices. These are differences for IEC requirements that may be acceptable, but adopting the IEC requirements would require considerable retesting or redesign on the manufacturer