1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60745-2-17Hand-Held Motor-Operated Electric Tools - Safety - Part 2-17: Particular Requirements forRouters and TrimmersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE
2、R REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60745-2-17Hand-Held Motor-Operated Electric Tools - Safety - Part 2-17: Particular Requirements for Routers andTrimmersEdition: 3Edition Date: February 25, 2011The revisions to ANSI/UL 60745-2-17 dated July 31, 2015 a
3、re being issued to reaffirm approvalthe standard as an American National Standard. No changes in requirements are involved.As noted in the Commitment for Amendments statement located on the back side of the titlepage, UL and CSA are committed to updating this harmonized standard jointly. However, th
4、erevision pages dated July 31, 2015 will not be jointly issued by UL and CSA as these revisionpages only address UL ANSI approval dates.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of thi
5、s publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,includ
6、ing but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or
7、theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electro
8、nic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on
9、 the purchasers computer system.Copyright 2015 Underwriters Laboratories Inc.JULY 31, 2015NATIONAL DIFFERENCES FOR UL UL 60745-2-172UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical
10、 National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1
11、- These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting
12、the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on edit
13、orial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be appli
14、ed to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subcl
15、ause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.J
16、ULY 31, 2015 NATIONAL DIFFERENCES FOR UL UL 60745-2-17 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational DifferencesM.8.12.2DV DR Modification: Add the following item:308) Information explaining the purpose and function of locking the
17、actuator in the OFFposition.M.21.18DV DR Modification: Add the following paragraph:The router table shall be provided with a means to prevent unauthorized use. A two-motiondevice alone shall not be considered an acceptable means.Note: Examples of acceptable methods are:a) Key-operated switch with a removable key;b) Toggle-operated switch with removable toggle;c) A means for locking the switch in the OFF position using a padlock;d) Electronic keypad lockout device.Compliance is checked by inspection.JULY 31, 2015NATIONAL DIFFERENCES FOR UL UL 60745-2-174