UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf

上传人:medalangle361 文档编号:1068579 上传时间:2019-04-02 格式:PDF 页数:131 大小:1.10MB
下载 相关 举报
UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf_第1页
第1页 / 共131页
UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf_第2页
第2页 / 共131页
UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf_第3页
第3页 / 共131页
UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf_第4页
第4页 / 共131页
UL 609-2018 UL Standard for Safety Local Burglar Alarm Units and Systems (Twelfth Edition).pdf_第5页
第5页 / 共131页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 609 Local Burglar Alarm Units and Systems STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL

2、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Local Burglar Alarm Units and Systems, UL 609 Twelfth Edition, Dated March 9, 2018 Summary of Topics The twelfth edition of the Standard for Local Burglar Alarm Units and Systems, UL 609, w

3、as issued to expand media to include website. The revised requirements are substantially in accordance with Proposal(s) on this subject dated October 23, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, e

4、lectronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL

5、 be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibi

6、lity of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, lia

7、bility, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MARCH 9, 2018 UL 609 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DI

8、STRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 UL 609 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 1 UL 609 Standard for Local Burglar Alarm Units and Systems Previous unnumbered editions of stan

9、dards covering this material have been published prior to 1928. The standards were titled Local Mercantile Burglar Alarm Systems and Local Burglar Alarm Systems for Bank Vaults and Safes. The rst through fourth editions were titled Local Burglar Alarm System and numbered both UL 609 and UL 610. Firs

10、t Edition April, 1942 Second Edition November, 1947 Third Edition November, 1950 Fourth Edition October, 1959 Fifth Edition May, 1963 Sixth Edition May, 1971 Seventh Edition January, 1972 Eighth Edition March, 1978 Ninth Edition June, 1982 Tenth Edition November, 1990 Eleventh Edition August, 1996 T

11、welfth Edition March 9, 2018 This ANSI/UL Standard for Safety consists of the Twelfth Edition. The most recent designation of ANSI/UL 609 as an American National Standard (ANSI) occurred on March 9, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page

12、. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed no

13、r electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 609-2018UL COPYRIGHTED MATERIAL NOT AUTHOR

14、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Co

15、mponents9 3 Units of Measurement .9 4 Undated References 9 5 Terminology 9 6 Glossary 10 7 Installation and Operating Instructions 13 8 Installation and Operating Instructions Physical Media13 9 Electric Shock .14 CONSTRUCTION ASSEMBLY 10 General15 10.1 Product assembly 15 10.2 Electrical protection

16、.15 11 Protection of Service Personnel 18 12 Enclosures .18 12.1 General .18 12.2 Doors and covers 20 12.3 Enclosure openings 21 12.4 Screens and expanded metal 24 12.5 Cast metal.24 12.6 Sheet metal .25 12.7 Product enclosure mounting .27 12.8 Polymeric materials.27 13 Corrosion Protection 28 FIELD

17、 WIRING CONNECTIONS 14 General28 15 Cord Connected Products .28 16 Permanently Connected Products.29 16.1 General .29 16.2 Field-wiring terminals .30 16.3 Field wiring leads.32 16.4 Polarity identication 33 17 Grounding .33 17.1 General .33 17.2 Cord Connected Appliances .34 INTERNAL WIRING 18 Gener

18、al35 19 Wiring Methods.35 20 Separation of Circuits .36 21 Bonding for Grounding 37 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 22 General41 22.1 Mounti

19、ng of components 41 22.2 Insulating materials 42 22.3 Fuseholders .43 22.4 Current-carrying parts.43 22.5 Power-on indicator .43 23 Overcurrent protection.43 24 Semiconductors 43 25 Switches.43 26 Transformers and Coils44 SPACINGS 27 General44 28 Components .46 PERFORMANCE ALL UNITS 29 General46 29.

20、1 Test units and data .46 29.2 Test samples and miscellaneous data 46 29.3 Test voltages 47 29.4 FCC requirements 47 30 Normal Operation Test 47 31 Current Protection Test 48 32 Input Test48 33 Output Measurement Test .48 34 Electrical Supervision Test .49 35 Undervoltage Operation Test .50 36 Overv

21、oltage Operation Test 50 37 Variable Ambient Test .50 38 Humidity Test 51 39 Leakage Current Tests for Cord-Connected Products .51 40 Electric Shock Current Test 55 41 Overload Test 59 41.1 General .59 41.2 Separately energized circuits 59 42 Endurance Test 60 42.1 General .60 42.2 Separately energi

22、zed circuits 60 43 Jarring Test 60 44 Dielectric Voltage-Withstand Test .61 45 Temperature Test.62 46 Abnormal Operation Test 66 47 Electrical Transient Tests 66 47.1 General .66 47.2 Supply line transients .66 47.3 Internally induced transients .68 47.4 Input/output circuit transients 68 48 AC Indu

23、ction Test.69 49 Polymeric Materials Test.70 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 50 Battery Replacement Test .70 51 Drop Test 70 52 Strain Relief Test .71 52.1 Supply

24、Cord .71 52.2 Field-wiring leads.71 53 Ignition Through Bottom-Panel Openings Tests.71 53.1 General .71 53.2 Hot aming oil .71 53.3 Molten pvc and copper72 54 Mechanical Strength Tests for Enclosures .73 55 Special Terminal Assemblies Tests .73 55.1 General .73 55.2 Disconnection and reconnection .7

25、4 55.3 Flexing test 74 55.4 Millivolt drop test .74 55.5 Temperature test .75 PROTECTED PREMISES EQUIPMENT 56 Subscribers Control Units .75 57 Outside Alarm Devices 75 58 Intrusion Detection 76 MERCANTILE PREMISES ALARM SYSTEMS GRADE A REQUIREMENTS 59 Construction .76 60 Circuit and Operation76 61 M

26、aintenance .77 62 Attack Tests78 62.1 General .78 62.2 Test method .78 63 Tamper Protection 79 64 Circuit and Operation81 MERCANTILE SAFE AND VAULT ALARM SYSTEMS DETAILS 65 General81 66 Circuit and Operation81 BANK SAFE AND VAULT ALARM SYSTEMS DETAILS 67 General81 68 Circuit and Operation82 69 Maint

27、enance .84 70 Attack Test.85 71 Tamper Protection 85 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL POWER SUPPLIES DETAILS 72 General86 RECHARGEABLE (SECONDARY) BATTERIES 73 Gene

28、ral87 NONRECHARGEABLE (PRIMARY) BATTERIES 74 General88 PERFORMANCE 75 Power Failure Test89 SHORT RANGE RADIO FREQUENCY (RF) DEVICES 76 General90 77 Time to Report Alarm .91 78 Inoperative Transmitter Reporting.91 79 Battery Status Indication .92 80 Tamper Protection 92 81 Interference Protection 93

29、82 Reference Level Determination .93 82.1 General .93 82.2 Method I 93 82.3 Method 2 95 83 Interference Immunity .98 84 Frequency Selectivity99 85 Clash99 86 Clash Error .100 87 Error (Falsing) Rate 101 88 Throughput Rate 102 89 Transmitter Stability Test .103 90 Transmitter Accelerated Aging Test 1

30、03 91 Installation Instructions and User Manual .104 MANUFACTURING AND PRODUCTION LINE TESTS FOR HIGH-VOLTAGE PRODUCTS 92 General 104 93 Production Line Dielectric Voltage-Withstand Test .104 94 Production Line Grounding Continuity Test .105 MARKING 95 General 106 96 Marking Permanency Tests .108 MA

31、RCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OUTDOOR USE EQUIPMENT 97 Assembly .108 97.1 General 108 98 Construction 109 98.1 General 109 98.2 Corrosion protection .109 99 Field-

32、Wiring Connections .111 100 Internal Wiring .111 101 Components, Electrical Insulating Material .113 PERFORMANCE 102 Rain Test 113 103 Dust Test 116 104 Variable Ambient Test.116 105 Metallic Coating Thickness Test 116 106 Corrosion Tests 118 106.1 General .118 106.2 Salt spray (Fog)118 106.3 Moist

33、hydrogen sulde (H 2 S) air mixture 119 106.4 Moist carbon dioxide (CO 2 ) sulfur dioxide (SO 2 ) air mixture .119 107 Ultraviolet Light and Water Exposure Test .119 108 Accelerated Aging Tests for Gaskets, Sealing Compounds, and Adhesives 120 MARKING 109 General .121 ACCESSORY EQUIPMENT 110 General

34、.122 111 Construction .122 112 Performance (Installation) Test .123 113 Markings 123 APPENDIX A Standards for Components .A1 MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTROD

35、UCTION 1 Scope 1.1 These requirements cover construction, performance, and maintenance of local burglar-alarm units and systems for use in mercantile premises, mercantile safes and vaults, and bank safes and vaults. 1.2 As covered by these requirements, a local alarm system consists of protective ci

36、rcuits and devices, connected through control apparatus to an enclosed tamper-protected sounding device mounted on an outside wall of the building in which the protected property is situated. Intrusion into or disturbance of the units or wiring causes the sounding device to be actuated. The sounding

37、 device continues to operate until it is stopped by using the proper control key, by exhaustion of the power supply, or by action of an automatic timing element that is preset for a denite operating period. These systems usually operate within the limits of Class 2 remote control and signal circuits

38、 of Class 2 remote control and signal circuits as dened by Article 725 of the National Electrical Code, NFPA 70. 1.3 The operation of a local alarm system is partially under the control and domination of the owners or others interested in the property. However, it is required that systems be maintai

39、ned under the care and regular inspection service of the installing company. The installing company is expected to respond to troubles or calls for service promptly on report of the owner. See Maintenance, Sections 61 and 69. It is the responsibility of the owner to switch the system ON and OFF duty

40、 and to report malfunctioning of the system to the service company. 1.4 Local mercantile burglar-alarm systems are intended for the protection of mercantile premises or mercantile safes and vaults. 1.5 Local bank burglar-alarm systems are intended for the protection of bank safes and vaults. 1.6 Equ

41、ipment intended for combination burglar-alarm and re-protective signaling systems shall comply with the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864. 1.7 Devices installed on individual properties are further classied as to extent of protection at each location. Rules co

42、vering installation and classication (of extent) of alarm equipment at individual locations are published in the Standard for Installation and Classication of Burglar and Holdup Alarm Systems, UL 681, which should be consulted by burglar-alarm installers. MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND

43、SYSTEMS - UL 609 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list

44、 of standards covering components generally used in the products covered by this standard. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b)

45、 Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use

46、only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 4 Undate

47、d References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 5 Terminology 5.1 The term product as used in this standard refers to all types of local burglar alarm units a

48、nd systems. 5.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are rms. MARCH 9, 2018 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 9UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 6 Glossary 6.1 For t

49、he purpose of this standard, the following denitions apply. 6.2 ALARM SOUNDING DEVICE An audible signal appliance (bell, horn, siren, or speaker), complying with the requirements in the Standard for Audible Signaling Devices for Fire Alarm and Signaling Systems, Including Accessories, UL 464, and this standard, that is used to signal unauthorized entry or attempted entry into a protected area or object. 6.3 ALARM SOUNDING DEVICE HOUSING A housing, or the equivalent, that is used to