UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf

上传人:eventdump275 文档编号:1068646 上传时间:2019-04-02 格式:PDF 页数:6 大小:21.65KB
下载 相关 举报
UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf_第1页
第1页 / 共6页
UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf_第2页
第2页 / 共6页
UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf_第3页
第3页 / 共6页
UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf_第4页
第4页 / 共6页
UL 61010-2-030 (ND)-2012 National Differences For Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for t.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForSafety requirements for electrical equipment for measurement, control, and laboratory use Part2-030: Particular requirements for testing and measuring circuitsUL COPYRIGHT

2、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForSafety requirements for electrical equipment for measurement, control, and laboratory use Part 2-030:Particular requirements for testing and measuring circuitsFirst EditionEdition Dat

3、e:This revision to ANSI/UL 61010-2-030 is being issued to update the title page to reflect thereaffirmation of ANSI approval. No changes in requirements have been made. It is harmonizedwith Canada and co-published by CSA (Canadian Standards Association), ISA, and UL.This document provides a single l

4、isting of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithou

5、t prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, in

6、direct or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liabi

7、lity for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (inclu

8、ding reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2016 Underwriters Laboratories Inc.SEPTEMBER 16, 2016NATIONAL DIFFERENCES FOR2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE

9、R REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference

10、type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These a

11、re deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted unt

12、il a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference

13、 entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, figure,or annex. Addition is not meant to include adding select

14、words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as the addition,replacement or del

15、etion of certain words or the replacement of an entire clause, subclause, table, figure,or annex of the base IEC text.SEPTEMBER 16, 2016 NATIONAL DIFFERENCES FOR 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational DifferencesTable 101DV

16、DR Modify the values in Table 101 by replacing it with the following:Table 101DV CLEARANCES and CREEPAGE DISTANCES for measuring circuit TERMINALS with HAZARDOUS LIVEconductive partsVoltage on conductive parts of TERMINAL CLEARANCE and CREEPAGE DISTANCEV a.c. r.m.s. V d.c. mm30 300 60 414 0,8300 600

17、 414 848 1,0600 1 000 848 1 414 2,6NOTE Values are determined by calculation for REINFORCED INSULATION. Transients are not taken into account.101.3.3DV D2 Addition of the following test:101.3.3DV.1 If the function or range controls have any effect on the electricalcharacteristics of the input circui

18、t, these controls shall be changed to all possible settingswhile the input TERMINALS are connected to the maximum RATED source.101.3.4DV D2 Modification of 101.3.4 by deleting the following paragraph If themanufacturer-supplied test leads are permanently connected to the equipment, then theattached

19、test leads supplied by the manufacturer shall be used without modification.and replacing it with the following:101.3.4DV.1 The applicable tests of 101.3.2 and 101.3.3 shall be performed with the testleads specified above and shall be repeated with any test leads supplied with theequipment by the man

20、ufacturer.AA.2.1DV D2 Modification by replacing the last paragraph with the following:AA.2.1DV.1 MEASUREMENT CATEGORY II is applicable to test and measuring circuits connecteddirectly to utilization points (socket outlets and similar points) of the low-voltage MAINSinstallation. This part of the ins

21、tallation is expected to have a minimum of two levels ofovercurrent protective devices between the transformer and the connecting points of themeasuring circuit (see Table AA.1 and Figure AA.1).AA.2.2DV D2 Modification by replacing the first paragraph with the following:AA.2.2DV.1 MEASUREMENT CATEGO

22、RY III is applicable to test and measuring circuits connectedto the distribution part of the buildings low-voltage MAINS installation. This part of theinstallation is expected to have a minimum of one level of over-current protective devicesbetween the transformer and possible connecting points (see

23、 Table AA.1 and Figure AA.1).SEPTEMBER 16, 2016NATIONAL DIFFERENCES FOR4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAA.2.3DV D2 Modification by replacing the first paragraph with the following:AA.2.3DV.1 MEASUREMENT CATEGORY IV is applicab

24、le to test and measuring circuits connectedat the source of the buildings low-voltage MAINS installation. This part of the installationmay have no over-current protective devices between the transformer and connectingpoints of the measuring circuit (see Table AA.1 and Figure AA.1).SEPTEMBER 16, 2016 NATIONAL DIFFERENCES FOR 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 16, 2016NATIONAL DIFFERENCES FOR6No Text on This Page

展开阅读全文
相关资源
猜你喜欢
  • ITU-R BO 792 SPANISH-1992 Interference Protection Ratios for the Broadcasting-Satellite Service (Television) in the 12 GHz Band《12 GHz频段广播卫星业务(电视)的干扰保护比》.pdf ITU-R BO 792 SPANISH-1992 Interference Protection Ratios for the Broadcasting-Satellite Service (Television) in the 12 GHz Band《12 GHz频段广播卫星业务(电视)的干扰保护比》.pdf
  • ITU-R BO 792-1992 Interference Protection Ratios for the Broadcasting-Satellite Service (Television) in the 12 GHz Band《12G频段广播卫星业务(电视)的干扰保护比》.pdf ITU-R BO 792-1992 Interference Protection Ratios for the Broadcasting-Satellite Service (Television) in the 12 GHz Band《12G频段广播卫星业务(电视)的干扰保护比》.pdf
  • ITU-R BO 793 FRENCH-1992 Partitioning of noise between feeder links for the broadcasting-satellite service (BSS) and BSS down links《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf ITU-R BO 793 FRENCH-1992 Partitioning of noise between feeder links for the broadcasting-satellite service (BSS) and BSS down links《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf
  • ITU-R BO 793 SPANISH-1992 Partitioning of noise between feeder links for the broadcasting-satellite service (BSS) and BSS downlinks《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf ITU-R BO 793 SPANISH-1992 Partitioning of noise between feeder links for the broadcasting-satellite service (BSS) and BSS downlinks《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf
  • ITU-R BO 793-1992 Partitioning of Noise between Feeder Links for the Broadcasting-Satellite Service (BSS) and BSS Down Links《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf ITU-R BO 793-1992 Partitioning of Noise between Feeder Links for the Broadcasting-Satellite Service (BSS) and BSS Down Links《广播卫星业务(BSS)馈线链路和BSS下行链路之间噪音的分隔》.pdf
  • ITU-R BO 794 FRENCH-1992 Techniques for minimizing the impact on the overall BSS system performance due to rain along the feeder-link path《将降雨引起的沿馈线链路信道对广播卫星业务(BSS)性能的影响降至最小的技术》.pdf ITU-R BO 794 FRENCH-1992 Techniques for minimizing the impact on the overall BSS system performance due to rain along the feeder-link path《将降雨引起的沿馈线链路信道对广播卫星业务(BSS)性能的影响降至最小的技术》.pdf
  • ITU-R BO 794 SPANISH-1992 Techniques for minimizing the impact on the overall BSS system performance due to rain along the feeder-link path《将降雨引起的沿馈线链路信道对广播卫星业务(BSS)性能的影响降至最小的技术》.pdf ITU-R BO 794 SPANISH-1992 Techniques for minimizing the impact on the overall BSS system performance due to rain along the feeder-link path《将降雨引起的沿馈线链路信道对广播卫星业务(BSS)性能的影响降至最小的技术》.pdf
  • ITU-R BO 794-1992 Techniques for Minimizing the Impact on the Overall BSS System Performance Due to Rain Along the Feeder-Link Path《将降雨引起的沿馈线链路通道对BSS系统性能的影响降至最小的技术》.pdf ITU-R BO 794-1992 Techniques for Minimizing the Impact on the Overall BSS System Performance Due to Rain Along the Feeder-Link Path《将降雨引起的沿馈线链路通道对BSS系统性能的影响降至最小的技术》.pdf
  • ITU-R BO 795 FRENCH-1992 Techniques for alleviating mutual interference between feeder links to the BSS《减少广播卫星业务(BSS)馈线链路之间相互干扰的技术》.pdf ITU-R BO 795 FRENCH-1992 Techniques for alleviating mutual interference between feeder links to the BSS《减少广播卫星业务(BSS)馈线链路之间相互干扰的技术》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1