UL 969 CRD-2017 UL Standard for Safety Marking and Labeling Systems - Section Paragraph Reference Clause 7 3 1 and Table 7 4 Subject Addition of thermal shock requirements that had.pdf

上传人:unhappyhay135 文档编号:1069091 上传时间:2019-04-02 格式:PDF 页数:2 大小:28.81KB
下载 相关 举报
UL 969 CRD-2017 UL Standard for Safety Marking and Labeling Systems - Section  Paragraph Reference Clause 7 3 1 and Table 7 4 Subject Addition of thermal shock requirements that had.pdf_第1页
第1页 / 共2页
UL 969 CRD-2017 UL Standard for Safety Marking and Labeling Systems - Section  Paragraph Reference Clause 7 3 1 and Table 7 4 Subject Addition of thermal shock requirements that had.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): PGDQ2/8, PGUU2/8 and PGJI2/8Standard Number: UL 969Standard Title: Standard for Marking and Labeling SystemsEdition Date: May 30, 2017Edition Number: 5Section / Paragraph Reference: Clause 6.2.SUPERCE

3、DES PRIOR CERTIFICATION REQUIREMENT DECISION DATED JUNE 30,2017DECISION:Clause 6.2 : Pressure-sensitive labels - Samples are to be applied to cleaned test surfaces as describedbelow. Alternatively, if the manufacturer provides specific application instructions, the manufacturersinstructions shall be

4、 followed. The release liner is to be removed from the construction, and the sampleis to be held by the edges only and placed on the test surface with care to avoid bending and entrapmentof air. To attach the sample uniformly, including edges and corners, a roller is to be rolled back and forthacros

5、s the surface in each direction with manual pressure sufficient to provide uniform and completecontact with the test surface. A smooth-surfaced cylindrical roller (wood, plastic, or hard rubber) about1-1/4 in (31.8 mm) in diameter and 1-1/4 in (31.8 mm) wide may be used.a steel roller 3.25 0.1 inch

6、802.5 mm) in diameter and 1.75 0.05 inches (45 1 mm) wide with a rubber coating that has a durometerhardness of 80 5 Shore A is to be used. The entire roller shall weigh 4.5 0.1 lbs (2000 50 g).The label should be rolled back and forth in the lengthwise direction. The sample shall be rerolled if it

7、appears that any air is trapped between the label and the surface.RATIONALE FOR DECISION:The revision to Clause 6.2 is intended to clarify all the specifics of the construction of the roller that is usedto apply the label samples to the test panels.No action will be required to add these modificatio

8、ns to the standard.Copyright 2017 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are

9、 the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requiremen

10、t Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULThis document is published as a service to ULs certification customersSTANDARD NUMBER: UL 969 -2-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2623-2014 Standard Practice for Reporting Thermometer Calibrations《温度计校准报告的标准实践规程》.pdf ASTM E2623-2014 Standard Practice for Reporting Thermometer Calibrations《温度计校准报告的标准实践规程》.pdf
  • ASTM E2624-2009 Standard Practice for Torque Calibration of Testing Machines and Devices《测试机械和装置扭矩校准用标准规程》.pdf ASTM E2624-2009 Standard Practice for Torque Calibration of Testing Machines and Devices《测试机械和装置扭矩校准用标准规程》.pdf
  • ASTM E2624-2015 Standard Practice for Torque Calibration of Testing Machines 《试验机扭矩标定的标准实施规程》.pdf ASTM E2624-2015 Standard Practice for Torque Calibration of Testing Machines 《试验机扭矩标定的标准实施规程》.pdf
  • ASTM E2624-2017 Standard Practice for Torque Calibration of Testing Machines《试验机扭矩校准的标准实施规程》.pdf ASTM E2624-2017 Standard Practice for Torque Calibration of Testing Machines《试验机扭矩校准的标准实施规程》.pdf
  • ASTM E2625-2009 Standard Practice for Controlling Occupational Exposure to Respirable Crystalline Silica for Construction and Demolition Activities《控制在建筑及拆卸活动中因职业性接触吸入结晶硅的标准方法》.pdf ASTM E2625-2009 Standard Practice for Controlling Occupational Exposure to Respirable Crystalline Silica for Construction and Demolition Activities《控制在建筑及拆卸活动中因职业性接触吸入结晶硅的标准方法》.pdf
  • ASTM E2625-2009(2017) Standard Practice for Controlling Occupational Exposure to Respirable Crystalline Silica for Construction and Demolition Activities《控制建筑和拆除活动的可吸入结晶硅的职业暴露的标准实施.pdf ASTM E2625-2009(2017) Standard Practice for Controlling Occupational Exposure to Respirable Crystalline Silica for Construction and Demolition Activities《控制建筑和拆除活动的可吸入结晶硅的职业暴露的标准实施.pdf
  • ASTM E2626-2008 Standard Guide for Spectrometric Analysis of Reactive and Refractory Metals.pdf ASTM E2626-2008 Standard Guide for Spectrometric Analysis of Reactive and Refractory Metals.pdf
  • ASTM E2627-2010 Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials《在完全再结晶的多晶体物质中使用.pdf ASTM E2627-2010 Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials《在完全再结晶的多晶体物质中使用.pdf
  • ASTM E2627-2013 Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials《使用完全再结晶多晶材料中的电子.pdf ASTM E2627-2013 Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials《使用完全再结晶多晶材料中的电子.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1