UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf

上传人:fuellot230 文档编号:1069168 上传时间:2019-04-02 格式:PDF 页数:48 大小:187.03KB
下载 相关 举报
UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf_第1页
第1页 / 共48页
UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf_第2页
第2页 / 共48页
UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf_第3页
第3页 / 共48页
UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf_第4页
第4页 / 共48页
UL SUBJECT 1384-2016 Outline of Investigation for Water-Based Automatic Extinguisher Units (Issue 4)《水基自动灭火装置的UL调查大纲 (议题4)》.pdf_第5页
第5页 / 共48页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 24, 20161UL 1384Outline of Investigation for Water-Based Automatic Extinguisher UnitsIssue Number: 4August 24, 2016Summary of TopicsThe Fourth Issue of the Outline of Investigation for Wat

2、er-BasedAutomatic Extinguisher Units, UL 1384, is being issued to includerequirements for alternate light and water exposure.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines o

3、f Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 24, 2016UL 13

4、842No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Components 53 Units of Measurement .54 Undated References 65 Glossary .6CONSTRUCTION6 General 77 Controls and Indicators 88 Caps, Valves, an

5、d Closures 99 Pressure Vessels and Cylinders 910 Pressure Relief Devices for Pressure Vessels and Cylinders .1311 Gaskets and O Rings 1312 Pressure Gauges for Pressure Vessels and Cylinders .1313 Puncturing Mechanisms .1414 Siphon Tubes 1415 Extinguishing Agent .1516 Expellant Gases 1517 Polymeric M

6、aterials and Nonmetallic Parts .1518 Anti-Recoil Devices .1619 Gas Cartridges .1620 Pressure Switches 1621 Flexible Hose Assemblies Used for Distribution of Agent 1722 Nozzles 1723 Protective Covers .1724 Strainer and Filter .18PERFORMANCE25 General 1826 Fire Test Total Flooding Protection 1826.1 Ge

7、neral .1826.2 Class A fire tests .1926.3 Class B fire tests .2026.4 Automatic operation extinguishment tests .2226.4.2 Test enclosures 2326.4.3 Test arrangement procedure .2327 Locking Indicator Test .2428 Nozzle Water Flow Test 2429 Nozzle Function Test .2530 Nozzle Specific Corrosion Tests .2530.1

8、 Sulfur dioxide/carbon dioxide corrosion .2530.2 Hydrogen sulfide corrosion 2630.3 Salt spray corrosion 2631 Agent Exposure Test 2732 Flow Distribution Tests 2733 Hydrostatic Pressure Test .28AUGUST 24, 2016 UL 1384 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITH

9、OUT PERMISSION FROM UL33.1 Pressure vessels and gas cartridges 2833.2 Other devices subject to pressure 2933.3 Test method .3034 30-Day Elevated Temperature Test .3035 Temperature Cycling Test .3136 Salt Spray Corrosion Test .3137 500 Cycle Operation Test .3238 One-Year Time Leakage Test 3239 Mounti

10、ng Device Test .3340 Flexible Hose Assembly Low Temperature Test 3341 Flexible Hose Assembly Cycling Test .3342 Flexible Hose Assembly Fire Exposure Test .3443 Pneumatic Operation Test .3444 Pressure Relief Tests .3545 Elastomeric Parts Test 3546 10-Day Moist Ammonia Air Stress Cracking Test .3647 A

11、ging Tests Plastic Materials .3747.1 Air-oven aging test .3747.2 Exposure to extinguishing agent test .3847.3 Light and water test 3848 Calibration Test Gauges and Indicators 3949 Burst Strength Test Gauges and Indicators 4050 Overpressure Test Gauges .4051 Impulse Test Gauges 4052 Pressure Gauge Re

12、lief Test 4153 Water Resistance Test Gauges and Indicators .4154 Nameplate Exposure Tests 4155 Nameplate Adhesion Test .4256 Nameplate Abrasion Test 42MANUFACTURING AND PRODUCTION TESTS57 General 4357.1 Manufacturers tests 4357.2 Hydrostatic pressure test shells 4357.3 Non-DOT gas cartridges 4357.4

13、Gauge calibration test 4457.5 Leakage test .44PACKING FOR SHIPMENT58 General 44MARKINGS59 General 45INSTALLATION INSTRUCTIONS60 Installation, Operation, and Maintenance Instruction Manual .4761 Owners Manual 48AUGUST 24, 2016UL 13844UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORD

14、ISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover the construction and operation of water-based automatic extinguisher unitsintended for total flooding applications when installed, inspected, tested, and maintained in accordancewith the manufacturers instructions.

15、1.2 Automatic extinguisher units do not have a manual means of operation, and are not intended forprotection of fire risks larger than those specified in the manufacturers instructions for a single unit byusing multiple units.2 Components2.1 Except as indicated in 2.2, a component of a product cover

16、ed by this outline shall comply with therequirements for that component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline; orb) Is superseded by a r

17、equirement in this outline.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited condi

18、tions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 The metric unit shall be designated as the official unit for purposes of this standard. Where values ofmeasurement are specified in both SI and English

19、units, either unit is used. In cases of dispute, the metricunit shall be used.AUGUST 24, 2016 UL 1384 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to a code or standard appearing in the require

20、ments of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this outline, the following definitions apply.5.2 ACTUATOR ASSEMBLY A pressure vessel pressurized with an inert gas or a liquid and inert gasthat includes a valve; o

21、r a gas cartridge pressurized with an inert gas that includes a puncture disc, whichupon automatic means of actuation, releases pressure resulting in the discharge process.5.3 AUTOMATIC EXTINGUISHER UNIT A unit that has no manual means of actuation and dischargesextinguishing agent upon thermal actu

22、ation, and is intended for use in a normally unoccupied space andis limited to a single protected area.5.4 CYLINDER/VALVE ASSEMBLY A container that incorporates a valve and that provides storage ofthe extinguishing agent and expellant gas until the valve is actuated. For cartridge operated units, th

23、isassembly includes the dry chemical storage container and cartridge mechanism. When actuated, thevalve releases the agent into the distribution network of the extinguisher unit.5.5 DISCHARGE NOZZLE A device that is used to uniformly distribute the extinguishing agent over orinto a specific area, or

24、 within a specific volume, or both.5.6 DISCHARGE RATE The ratio of the quantity of agent discharged from a nozzle to the dischargetime measured within 1 second. When a minimum discharge rate is indicated, reference is made to theminimum quantity of agent discharged and the time measured within 1 sec

25、ond.5.7 DISCHARGE TIME The time interval between the first appearance of extinguishing agent at thenozzle and the time at which the discharge becomes predominantly gaseous.5.8 EXPELLANT GAS Dry nitrogen, dry air, or other gas used to facilitate the discharge of theextinguishing agent.5.9 GAS CARTRID

26、GE A container that provides storage for an expellant gas.5.10 HEPTANE A commercial grade hydrocarbon used as a test fuel with the following characteristics:a) Minimum Initial boiling point 88C (190F),b) Maximum Dry point 100C (212F), andc) Specific gravity (60F/60F) (15.6C/15.6C) 0.69 0.73.5.11 MET

27、HOD OF ACTUATION, AUTOMATIC A means of actuation that results in extinguishing agentdischarge without the necessity of human intervention, such as a thermal actuating mechanism.AUGUST 24, 2016UL 13846UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FR

28、OM UL5.12 OPERATING PRESSURE The pressure in a fully charged cylinder/valve assembly or actuationassembly at 21C (70F).5.13 OPERATING PRESSURE RANGE The pressure range corresponding to the pressures within theagent storage container at the specified minimum and maximum temperatures for which the aut

29、omaticextinguisher unit is intended to be operated.5.14 OPERATING TEMPERATURE RANGE The temperature range inclusive of the minimum andmaximum temperatures for which the automatic extinguisher unit is intended to be stored, used, andoperated.5.15 PRESSURE VESSEL (CYLINDER) A container that provides s

30、torage for dry chemicalextinguishing agent and expellant gas, or when used at a location remote to the extinguisher unit, providesstorage for expellant gas.5.16 PROOF TEST PRESSURE The factory test pressure of each cylinder used to evaluate cylinderleakage and construction integrity. For Department

31、of Transportation (DOT) approved cylinders, thefactory test pressure is specified in the appropriate DOT specification. For ASME vessels the factory testpressure is specified in Section VIII, Pressure Vessels of the ASME Boiler and Pressure Vessel Code. Fornon-DOT cylinders and non-ASME cylinders, t

32、he factory test pressure is at least three times the cylinderoperating pressure at 70F (21C).5.17 PROTECTED VOLUME For fire tests, the volume within the protected enclosure, minus thevolume of any permanent impermeable building elements within the enclosure.5.18 TOTAL FLOODING Discharge an extinguis

33、hing agent into and throughout an enclosed space toachieve a uniform distribution of the extinguishing agent.5.19 WATER-BASED EXTINGUISHING AGENT A fire-extinguishing medium consisting of water andadditives to enhance performance.CONSTRUCTION6 General6.1 After discharge of the extinguishing agent is

34、 initiated, an automatic extinguisher unit shall maintain themaximum rate of application of extinguishing agent without requiring a manual action.6.2 All exposed parts of an automatic extinguisher unit and automatic extinguisher unit, including thefinishes on coated or painted parts, nameplates as s

35、ecured in place, attachments such as mountingbrackets required for installation, assemblies of moving parts, or other similar parts, shall be resistant tocommonly encountered atmospheric corrosive influences, and to galvanic corrosion, as determined by theSalt Spray Corrosion Test.6.3 When the deter

36、ioration, breakage or other malfunction of a part for an automatic extinguisher unitpresents a risk of the unit becoming inoperable, the part shall not be susceptible to stress cracking, asdetermined by the Stress Corrosion Cracking Test for Brass Parts.AUGUST 24, 2016 UL 1384 7UL COPYRIGHTED MATERI

37、AL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6.4 As covered by these requirements, an automatic extinguisher unit consists of:a) Extinguishing agent storage container;b) Actuating assembly;c) Indicators that show the condition of the storage container and, when

38、 applicable, actuatingassembly;d) Discharge nozzle or nozzles; ande) Mounting bracket(s).6.5 An automatic extinguisher unit shall have a minimum operating temperature of no less than minus54C (minus 65F) and a maximum operating temperature of no greater than 65C (150F).6.6 The pressure vessels of st

39、orage containers shall comply with the requirements of the U.S.Department of Transportation (DOT) or local transport equivalent.7 Controls and Indicators7.1 An automatic extinguisher unit shall be provided with the following controls and indicators:a) An automatic means of actuation only.b) A pressu

40、re gauge for each pressure vessel of storage containers, showing the pressurewithin the container.7.2 The thermal actuating mechanism of an automatic extinguisher unit shall comply with the applicablerequirements of the Standard for Heat Responsive Links for Fire-Protection Service, UL 33; or theSta

41、ndard for Heat Detectors for Fire Protective Signaling Systems, UL 521.7.3 An automatic extinguisher unit that requires setup of a device, such as the movement of a valve, toplace the unit in the set condition shall be provided with a locking indicator on the device to maintain theunit in the set co

42、ndition. A locking indicator shall be made of corrosion-resistant material and shall complywith the Salt spray Corrosion Test.7.4 A locking indicator shall break when subjected to a force of 65 N (15 lb-f) or less when subjected tothe Locking Indicator Test.7.5 Upon activation, an automatic extingui

43、sher unit intended for Class C applications shall includeauxiliary equipment to shut down all sources of fuel and electric power to all equipment within theprotected volume.AUGUST 24, 2016UL 13848UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM U

44、L8 Caps, Valves, and Closures8.1 The fill opening of an automatic extinguisher unit shall have a minimum inside diameter of 6 mm (1/4inch).8.2 A collar with external threads shall be as high as required so the cap does not contact the dome orthe bottom of the pressure vessel when the gasket is remov

45、ed.8.3 A threaded cap, closure, or valve shall engage the collar or the threaded opening by not less thanfour full threads with the gasket in place.8.4 A cap, valve, or closure shall withstand the hydrostatic pressure test as specified for the pressurevessel.8.5 A cap, plug, cylinder valve or other

46、component except a pressure gauge, shall be provided with ameans of relieving pressure when it is removed while the storage container is still under pressure. Thepressure shall be relieved with not less than two threads engaged.9 Pressure Vessels and Cylinders9.1 A pressure vessel shall be fabricate

47、d of a material having rigidity, durability, and resistance tocorrosion at least equivalent to:a) A mild steel alloy, such as SAE 1010, having a minimum thickness of 0.71 mm (0.028 inch).b) An aluminum alloy, such as 6061-T6, as referenced in the Standard Specification forAluminum and Aluminum-Alloy

48、 Sheet and Plate, ASTM B209, having a minimum thickness of0.71 mm (0.028 inch); orc) An aluminum alloy, such as 1100, 1170, and 3003, having a minimum thickness of 0.71 mm(0.028 inch).9.2 The requirements in this section do not apply to a pressure vessel tested and marked as complyingwith DOT or oth

49、er appropriate national specifications, unless otherwise specifically indicated.9.3 A pressure vessel under the jurisdiction of the U.S. Department of Transportation shall comply withthe appropriate DOT specifications for shipping containers.9.4 A pressure vessel under the jurisdiction of a transport authority other than the U.S. Department ofTransportation shall comply with the appropriate national specifications for shipping containers.9.5 For the purpose of these requirements, thickness measurements o