1、05-01-12 07 32 13 1 SECTION 07 32 13 CLAY ROOF TILES PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies the installation of roofing tiles. B. Related work 1. Metal Flashing: Section 07 60 00, FLASHING AND SHEET METAL. 2. Style, size, exposure, color and texture of clay tile: Section 09 06 00

2、 SCHEDULE FOR FINISHES. 3. Sealants and Applicable: Section 07 92 00, JOINT SEALANTS. 1.2 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Samples: Tiles to show color range. C. Shop Drawings: Details of fabricated custom shapes. 1.3 PRODUCT DEL

3、IVERY, STORAGE AND HANDLING A. Deliver tiles and setting materials in manufacturers original, unopened containers clearly identifying manufacturer and the contents. B. Do not store tiles in flat position. 1.4 WARRANTY Warrant materials and workmanship to be free from defects and leaks and subject to

4、 the terms of the “Warranty of Construction“, FAR clause 52.246-21, except that warranty period is two years. 1.5 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation

5、only. B. American Society for Testing and Materials (ASTM): A580-08 Stainless Steel Wire B99-11 . Copper - Silicon Alloy Wire for General Applications C270-12 Mortar for Unit Masonry C920-11 Elastomeric Joint Sealants C1167-11 . Clay Roof Tiles D226-09 Asphalt-Saturated Organic Felt Used in Roofing

6、and Waterproofing D4586-07 . Asphalt Roof Cement, Asbestos Free F1667-11 . Driven Fasteners: Nails, Spikes, and Staples Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-01-12 07 32 13 2 PART 2 - PRODUCTS SPEC WRITER NOTES: 1. Delete between / _ / i

7、f not applicable. 2. Make material requirements agree with applicable requirements (types, grades, classes and other related items) specified in the referenced Applicable Publications. 3. Select clay tile type desired (English French, Greek, Mission, Roman or Spanish) and insure tile are clearly det

8、ailed on drawings especially edge and flashings at penetrations and hips and valleys. 4. Insure wood deck is not less than 19 mm (3/4 inch) thick. 2.1 CLAY ROOF TILES A. ASTM C1167, Grade 1, providing resistance to severe frost action, Type, I, High profile, Type II, low profile, Type III, other, in

9、cluding flat. B. Special shapes: Eave closures, under eave piece, gable rake, and hands, valley, ridge covers, top fixtures, and other shapes required. C. For repairs, match existing tile for color and shape. 2.2 ROOF CEMENT A. ASTM D4586, Type II. B. Modified bituminous types are acceptable. 2.3 NA

10、ILS BRADS, STAPLES AND SPIKES A. ASTM F1667. B. Nails: Type I, Style 23, Hard copper roofing nails length for 19 mm (3/4 inch) penetration into deck. C. Staples: Type IV, Style 3, Flat top crown staple, zinc coated. 2.4 FELT UNDERLAYMENT A. ASTM D226, Type II, nominal 13.6 kg (30 pounds.) B. Without

11、 perforations. 2.5 MORTAR A. ASTM C270. B. Type N or 0. 2.6 SEALANT A. ASTM C920, Type S or M, Grade NS Class 25. B. Use Polyurethane, Shore hardness 15-25. 2.7 WIRE A. Stainless steel: ASTM A580, Type 302 or 304, minimum 0.74 mm (0.029 inch) diameter. B. Copper: ASTM B99, minimum 1.27 mm (0.05 inch

12、) diameter. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-01-12 07 32 13 3 PART 3 - EXECUTION 3.1 JOB CONDITIONS A. Do not set tiles in mortar when the ambient temperature is less than 4 C (40 F). B. Do not start installation until other trades

13、requiring traffic on roof have completed their work. C. Do not start installation until vent pipes and other projections through roofs and flashing materials are in place. 3.2 LAYING FELT UNDERLAYMENT A. Lay single thickness of felt parallel to eaves with double thickness at hips, valleys, and ridge

14、s, under tile roofing. B. Lap horizontal joints 75 mm (3 inches) and vertical joints 150 mm (6 inches) with vertical joints staggered. Lap in direction of flow. C. Extend felt up 150 mm (6 inches) at abutting vertical walls, chimneys and parapets. D. Lap felt not less than 100 mm (4 inches) under ed

15、ges at built-in gutters, valleys, flashing, and metal flashings. E. Staple felt 125 mm (5 inches) on centers along laps and edges. 3.3 LAYING TILE A. Lay courses parallel with eaves. B. Do not stretch courses. C. Space course to finish even and parallel at top of level terminations. D. Fit tiles clo

16、sely at ridges, around vent pipes, flashing and other like projections through roof. E. Secure tile by at least two nails, where practicable. F. Use copper or stainless steel wire fastening where nails are not used through tile. G. Cover nails and wire fastenings in finished work. H. Lay tile with a

17、n end lap of at least 75 mm (3 inches). I. Recess eave closure of pan and cover tile at least 38 mm (1-1/2 inches) from lower end of tile. J. Fill laps of ends bands, of cover tile on ridges, and of gable rakes to end bands and field tiles with roof cement. 1. Limit amount of roof cement used for le

18、veling tile to 6 mm (1/4 inch) thickness. 2. Use mortar for leveling and bedding tile where thickness exceeds 6 mm (1/4 inch). K. Use sealant for pointing around eave closures ridge cover joints, and top fixtures. Provided by IHSNot for ResaleNo reproduction or networking permitted without license f

19、rom IHS-,-,-05-01-12 07 32 13 4 1. Apply sealant cap bead over exposed fasteners sealing opening. 2. Apply as specified in Section 07 92 00, JOINT SEALANTS. L. Coordinate with Section 07 60 00, FLASHING AND SHEET METAL for installation of flashing with tile work. Keep flashing concealed except where

20、 exposed on vertical surfaces or Counterflashing (cap). 3.4 CLEANING AND REPAIR A. Upon completion remove any cement splatter from tile and adjacent surfaces. B. Replace broken, cracked, or stained tile with discolored surface. - - - E N D - - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • GOST R ISO 10320-2014 Geotextiles and geotextile-related products Identification on site《土工织物及其相关产品 现场识别》.pdf GOST R ISO 10320-2014 Geotextiles and geotextile-related products Identification on site《土工织物及其相关产品 现场识别》.pdf
  • GOST R ISO 10325-2012 8-strand braided ropes 12-strand braided and covered ropes from high modulus polyethylene fibers General technical requirements《高模量聚乙烯纤维制成的8股编织绳索 12股编织绳索和包覆绳索.pdf GOST R ISO 10325-2012 8-strand braided ropes 12-strand braided and covered ropes from high modulus polyethylene fibers General technical requirements《高模量聚乙烯纤维制成的8股编织绳索 12股编织绳索和包覆绳索.pdf
  • GOST R ISO 10326-1-1999 Mechanical vibration Laboratory method for evaluating vehicle seat vibration Part 1 Basic requirements《机械振动 评估座椅震动的实验室方法 第1部分 基本要求》.pdf GOST R ISO 10326-1-1999 Mechanical vibration Laboratory method for evaluating vehicle seat vibration Part 1 Basic requirements《机械振动 评估座椅震动的实验室方法 第1部分 基本要求》.pdf
  • GOST R ISO 10332-1999 Seamless and welded ( except submerged arc-welded) steel tubes for pressure purposes Ultrasonic testing for the verification of hydraulic leak-tightness《压力无缝焊.pdf GOST R ISO 10332-1999 Seamless and welded ( except submerged arc-welded) steel tubes for pressure purposes Ultrasonic testing for the verification of hydraulic leak-tightness《压力无缝焊.pdf
  • GOST R ISO 10341-2013 Ophthalmic instruments Refractor heads《眼科器械 折射透镜突出部》.pdf GOST R ISO 10341-2013 Ophthalmic instruments Refractor heads《眼科器械 折射透镜突出部》.pdf
  • GOST R ISO 10393-2014 Consumer product recall Guidelines for suppliers《消费者产品召回 供应商指南》.pdf GOST R ISO 10393-2014 Consumer product recall Guidelines for suppliers《消费者产品召回 供应商指南》.pdf
  • GOST R ISO 10396-2012 Stationary source emissions Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems《固定源排放 永久安装监测系.pdf GOST R ISO 10396-2012 Stationary source emissions Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems《固定源排放 永久安装监测系.pdf
  • GOST R ISO 10467-2013 Glass-reinforced thermosetting plastics piping systems based on unsaturated poliester resins for pressure and non-pressure drainage and severage General techn.pdf GOST R ISO 10467-2013 Glass-reinforced thermosetting plastics piping systems based on unsaturated poliester resins for pressure and non-pressure drainage and severage General techn.pdf
  • GOST R ISO 105-A04-1999 Textiles Tests for colour fastness Part A04 Method for the instrumental accessment of the degree of staining of adjacent fabrics《纺织品 色牢度测试 第A04部分 贴衬织物染斑程度的仪.pdf GOST R ISO 105-A04-1999 Textiles Tests for colour fastness Part A04 Method for the instrumental accessment of the degree of staining of adjacent fabrics《纺织品 色牢度测试 第A04部分 贴衬织物染斑程度的仪.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1