1、01-10 08 14 00-1 SECTION 08 14 00 INTERIOR WOOD DOORS SPEC WRITER NOTE: 1. Delete between / _/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. See VA Standard Details for types of doors and designations. 2. See VA Physi

2、cal Security Design Guide for security requirements PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies interior flush doors / and stile and rail doors / with prefinish, prefit option. B. Section includes / fire rated doors, / sound retardant doors, / smoke, / and / dutch doors /. 1.2 RELATED

3、 WORK A. Metal door frames: Section 08 11 13, HOLLOW METAL DOORS AND FRAMES. B. Doors and frames of a forced entry/ballistic resistant rated: Section 08 34 53, SECURITY DOORS AND FRAMES. C. Overhead doors including loading docks: Section 08 33 00, COILING DOORS AND GRILLES. D. Windows and frames of

4、a forced entry/ballistic resistant rated: Section 08 56 53, SECURITY WINDOWS E. Door hardware including hardware location (height): Section 08 71 00, DOOR HARDWARE. F. Installation of doors and hardware: Section 08 11 13, HOLLOW METAL DOORS AND FRAMES, Section 08 14 00, WOOD DOORS, or Section 08 71

5、00, DOOR HARDWARE. G. Glazing and ballistic rated glazing: Section 08 80 00, GLAZING. H. Finish: Section 09 06 00, SCHEDULE FOR FINISHES. I. Metal louvers: Section 08 90 00, LOUVERS AND VENTS. J. Lead lined wood door: Section 13 49 00, RADIATION PROTECTION. K. Card readers and biometric devices: Sec

6、tion 28 13 00, ACCESS CONTROL L. Intrusion alarm: Section 28 16 11, INTRUSION DETECTION SYSTEM M. Security monitors: Section 28 51 00, SECURITY CONTROL CENTER 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Provided by IHSNot for ResaleNo repro

7、duction or networking permitted without license from IHS-,-,-01-10 08 14 00-2 SPEC WRITER NOTE: Paragraph B, delete subparagraph No. 1 on projects not involving large numbers of wood doors. Delete sub-paragraph No. 2 on projects where no transparent door finishes are required. Samples are not requir

8、ed for projects involving 10 wood doors or less. B. Samples: /1. Corner section of flush veneered door 300 mm (12 inches) square, showing details of construction, labeled to show grade and type number and conformance to specified standard. / /2. Veneer sample 200 mm (8 inch) by 275 mm (11 inch) by 6

9、 mm (1/4 inch) showing specified wood species sanded to receive a transparent finish. Factory finish veneer sample where the prefinished option is accepted. / C. Shop Drawings: 1. Show every door in project and schedule location in building. 2. Indicate type, grade, finish and size; include detail o

10、f / glazing / louvers / sound gasketing / and pertinent details. 3. Provide information concerning specific requirements not included in the manufacturers literature and data submittal. D. Manufacturers Literature and Data: /1. Sound rated doors, including test report indicating STC rating per ASTM

11、E90 from test laboratory. / /2. Labeled fire rated doors showing conformance with NFPA 80. / E. Laboratory Test Reports: 1. Screw holding capacity test report in accordance with WDMA T.M.10. 2. Split resistance test report in accordance with WDMA T.M.5. 3. Cycle/Slam test report in accordance with W

12、DMA T.M.7. 4. Hinge-Loading test report in accordance with WDMA T.M.8. 1.4 WARRANTY A. Doors are subject to terms of Article titled “Warranty of Construction”, FAR clause 52.246-21, except that warranty shall be as follows: 1. For interior doors, manufacturers warranty for lifetime of original insta

13、llation. /2. Specified STC RATING for sound retardant rated door assembly in place. / Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-3 1.5 DELIVERY AND STORAGE SPEC WRITER NOTE: These bags or packages will be required to be reinstalle

14、d on doors after installation, see Paragraph, DOOR PROTECTION. A. Factory seal doors and accessories in minimum of 6 mill polyethylene bags or cardboard packages which shall remain unbroken during delivery and storage. B. Store in accordance with WDMA I.S.1-A, J-1 Job Site Information. C. Label pack

15、age for door opening where used. 1.6 APPLICABLE PUBLICATIONS Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only. B. Window and Door Manufacturers Association (WDMA): I.S.1-A-04 . Architectural Wood Flush Doo

16、rs I.S.4-07A Water-Repellent Preservative Non-Pressure Treatment for Millwork I.S.6A-01 Architectural Wood Stile and Rail Doors T.M.5-90 . Split Resistance Test Method T.M.6-08 . Adhesive (Glue Bond) Durability Test Method T.M.7-08 . Cycle-Slam Test Method T.M.8-08 . Hinge Loading Test Method T.M.10

17、-08 Screwholding Test Method C. National Fire Protection Association (NFPA): 80-07 Protection of Buildings from Exterior Fire 252-08 . Fire Tests of Door Assemblies D. ASTM International (ASTM): E90-04 . Laboratory Measurements of Airborne Sound Transmission Loss SPEC WRITER NOTES: 1. Make material

18、requirements agree with applicable requirements specified in the referenced Applicable Publications. 2. Update and specify only that which applies to the project. 3. Use 45 mm (1-3/4 inch) thick doors for medical facilities, nursing homes and domiciliary buildings. 4. Use 35 mm (1-3/8 inch) thick do

19、ors for office buildings and cemetery type buildings, unless facility requests 45 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-4 mm thick doors or doors that are fire rated. PART 2 - PRODUCTS 2.1 FLUSH DOORS A. General: 1. Meet requ

20、irements of WDMA I.S.1-A, Extra Heavy Duty. 2. Adhesive: Type II 3. Thickness: 45 mm (1-3/4 inches) unless otherwise shown or specified. /4. Give exposed wood parts of exterior doors a water-repellent preservative treatment in accordance with WDMA I.S.4. / SPEC WRITER NOTE: For face veneer other tha

21、n those specified below see WDMA I.S.1-A, Section G-11, Face Veneer Characteristics, regarding AA and A grade door faces. See section A-3, Appearance of Individual Pieces of Face Veneer; A-4, Matching Between Individual Veneer Pieces; A-5, Assembly of Spliced Veneer on Door Face; and A-6, Appearance

22、 of Doors in pairs or sets. For highest quality paint finish, specify medium density overlay faces only. B. Face Veneer: 1. In accordance with WDMA I.S.1-A. 2. One species throughout the project unless scheduled or otherwise shown. 3. For transparent finishes: / Premium Grade. rotary cut, / white ma

23、ple / white Birch / red oak / white oak / _/. a. A grade face veneer standard optional. b. AA grade face veneer c. Match face veneers for doors for uniform effect of color and grain at joints. d. Door edges shall be same species as door face veneer except maple may be used for stile face veneer on b

24、irch doors. /e. On doors required to have transparent finish on one side and paint finish on other side; use veneers as required for transparent finish on both sides. / /f. In existing buildings, where doors are required to have transparent finish, use wood species and grade of face veneers to match

25、 adjacent existing doors./ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-5 4. For painted finishes: Custom Grade, mill option close grained hardwood, premium or medium density overlay. Do not use Lauan. 5. Factory sand doors for fini

26、shing. C. Wood for stops, louvers, muntins and moldings of flush doors required to have transparent finish: 1. Solid Wood of same species as face veneer, except maple may be used on birch doors. 2. Glazing: a. On non-labeled doors use applied wood stops nailed tight on room side and attached on oppo

27、site side with flathead, countersunk wood screws, spaced approximately 125 mm (5 inches) on centers. b. Use stainless steel or dull chrome plated brass screws for exterior doors. 3. Wood Louvers: a. Door manufacturers standard product, fabricated of solid wood sections. b. Wood Slats: Not less than

28、5 mm (3/16 inch) thick. c. Stiles routed out to receive slats. d. Secure louvers in prepared cutouts with wood stops. D. Stiles and Rails: 1. Option for wood stiles and rails: a. Composite material having screw withdrawal force greater than minimum performance level value when tested in accordance w

29、ith WDMA T.M.10. 2. Provide adequate blocking for bottom of doors having mechanically operated door bottom seal meeting or exceeding the performance duty level per T.M.10 for horizontal door edge screw holding. /3. Rabbeted transom meeting rail edges match face veneers of doors. / Bottom rail of tra

30、nsom panel match face veneer on non rabbeted meeting rail edge./ SPEC WRITER NOTE: Do not use 60 minute B label doors or 20 minute doors. Solid core door, 45 mm (1-3/4 inches) give 20 minutes performance. E. Fire rated wood doors: 1. Fire Performance Rating: a. “B” label, 1-1/2 hours. b. “C” label,

31、3/4 hour. 2. Labels: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-6 a. Doors shall conform to the requirements of ASTM E2074, or NFPA 252, and, carry an identifying label from a qualified testing and inspection agency for class of d

32、oor or opening shown designating fire performance rating. b. Metal labels with raised or incised markings. 3. Performance Criteria for Stiles of doors utilizing standard mortise leaf hinges: a. Hinge Loading: WDMA T.M.8. Average of 10 test samples for Extra Heavy Duty doors. b. Direct screw withdraw

33、al: WDMA T.M.10 for Extra Heavy Duty doors. Average of 10 test samples using a steel, fully threaded #12 wood screw. c. Cycle Slam: 1,000,000 cycles with no loose hinge screws or other visible signs of failure when tested in accordance with WDMA T.M.7. 4. Additional Hardware Reinforcement: a. Provid

34、e fire rated doors with hardware reinforcement blocking. b. Size of lock blocks as required to secure hardware specified. c. Top, bottom and intermediate rail blocks shall measure not less than 125 mm (five inches) minimum by full core width. d. Reinforcement blocking in compliance with manufacturer

35、s labeling requirements. e. Mineral material similar to core is not acceptable. 5. Other Core Components: Manufacturers standard as allowed by the labeling requirements. 6. Provide steel frame approved for use in labeled doors for vision panels. 7. Provide steel astragal on pair of doors. F. Smoke B

36、arrier Doors: 1. For glazed openings use steel frames approved for use in labeled doors. 2. Provide a steel astragal on one leaf of pairs of doors, including double egress doors. G. Sound Rated Doors: 1. Fabricated as specified for flush wood doors with additional construction requirements to meet s

37、pecified sound transmission class (STC). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-7 2. STC Rating of the door assembly in place when tested in accordance with ASTM E90 by an independent nationally recognized acoustical testing l

38、aboratory not less than 36 /_ / . 3. Accessories: a. Frame Gaskets: Continuous closed cell sponge neoprene with stop adjusters. b. Automatic Door Bottom Seal: 1) Steel spring operated, closed cell sponge neoprene metal mounted removable in extruded aluminum housing with a medium matte 0.1 mm (4.0 mi

39、l) thick clear Anodized finish. 2) Concealed or Surface Mounted. H. Dutch Doors: 1. Consist of two sections, each fabricated as specified for flush doors. 2. Construct shelf as detailed, from clear hardwood stock, or laminated plastic door shelf, same species as face veneer of door. 3. Place shelf o

40、n top of lower section of door and support as shown with a pair of wood or wrought steel brackets. 4. Prime steel brackets for finish painting. 2.2 STILE AND RAIL DOORS A. Meeting requirements of WDMA I.S.6A B. Ponderosa pine doors of size and design shown. C. Grade: /Premium / Standard/. D. Door Pa

41、nels: 1. Grain of face of panels parallel with longest dimensions of panel. 2. Flat panels: Veneered composite core, not less than 6 mm (5/8 inch) thick. 3. Raised panels: Unless otherwise shown, thickness of raised panels not less than the following: a. For 35 mm (1-3/8 inch) and 45 mm (1-3/4 inch)

42、 thick doors: 28 mm (1-1/8 inch) thick b. For 57 mm (2-1/4 inch) thick doors: 41 mm (1-5/8 inch) thick 4. Where armor plate is required in connection with paneled doors, provide panels with plywood fillers, glued in place, and finished. E. Stops and Molds: 1. Solid sticking both sides, of same mater

43、ial as stiles and rails, coped at intersections. 2. Glazed openings applied wood stops nailed on interior side of door. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-10 08 14 00-8 F. Louvers: Size as shown. Spec Writer Note: If there are more th

44、an 10 doors at any project, doors to receive transparent finish shall be factory finished. 2.3 PREFINISH, PREFIT OPTION A. Flush doors may be factory machined to receive hardware, bevels, undercuts, cutouts, accessories and fitting for frame. B. Factory fitting to conform to specification for shop a

45、nd field fitting, including factory application of sealer to edge and routings. C. Flush doors to receive transparent finish (in addition to being prefit) /shall / may / be factory finished as follows: 1. WDMA I.S.1-A Section F-3 specification for System TR-4, Conversion Varnish or System TR-5, Cata

46、lyzed Vinyl. 2. Use stain when required to produce the finish specified in Section 09 06 00 SHEDULE FOR FINISHES. 2.4 IDENTIFICATION MARK: A. On top edge of door. B. Either a stamp, brand or other indelible mark, giving manufacturers name, doors trade name, construction of door, code date of manufac

47、ture and quality. C. Accompanied by either of the following additional requirements: 1. An identification mark or a separate certification including name of inspection organization. 2. Identification of standards for door, including glue type. 3. Identification of veneer and quality certification. 4

48、. Identification of preservative treatment for stile and rail doors. 2.5 SEALING: Give top and bottom edge of doors two coats of catalyzed polyurethane or water resistant sealer before sealing in shipping containers. PART 3 - EXECUTION 3.1 DOOR PREPARATION A. Field, shop or factory preparation: Do n

49、ot violate the qualified testing and inspection agency label requirements for fire rated doors. B. Clearances between Doors and Frames and Floors: 1. Maximum 3 mm (1/8 inch) clearance at the jambs, heads, and meeting stiles, and a 19 mm (3/4 inch) clearance at bottom, except as otherwise specified. Provided by IHSNot for R