VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf

上传人:testyield361 文档编号:1074740 上传时间:2019-04-06 格式:PDF 页数:13 大小:51.73KB
下载 相关 举报
VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf_第1页
第1页 / 共13页
VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf_第2页
第2页 / 共13页
VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf_第3页
第3页 / 共13页
VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf_第4页
第4页 / 共13页
VA 08 17 10-2012 INTEGRATED DOOR ASSEMBLIES.pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、03-01-12 08 17 10-1 SECTION 08 17 10 INTEGRATED DOOR ASSEMBLIES SPEC WRITER NOTE: Delete between / - / if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION A. Work in this section includes in

2、tegrated door opening systems including metal frame, integrated doors, hanging device, latching mechanism and associated finish hardware, unless specified elsewhere. B. Smoke and draft control seals shall be included in this section, unless specifically listed elsewhere. C. All glass and glazing are

3、 not covered in this section. 1.2 RELATED WORK A. Blocking for Hardware: Section 06 10 00, ROUGH CARPENTRY. B. Key Cylinders: Section 08 71 00, DOOR HARDWARE C. Auto Door Operators: Section 08 71 13, AUTOMATIC DOOR OPERATORS /Section 08 71 13.11, LOW ENERGY DOOR OPERATORS. D. Painting: Section 09 91

4、 00, PAINTING. E. Card Readers: Section 28 13 11, PHYSICAL ACCESS CONTROL SYSTEMS. F. Electrical: Division 26, ELECTRICAL. G. Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM. 1.3 QUALITY ASSURANCE A. Hardware shall be installed by people knowledgeable and skilled in the application, insta

5、llation and adjustment of commercial grade doors and door hardware. Doors and Frames must be installed plumb, square and level. B. Doors frames must be properly prepared and reinforced to install hardware per the manufacturers template and installation instructions. Install door frames in accordance

6、 with ANSI/SDI A250.11 “Recommended Erection Instructions for Steel Frames.” C. Contractor shall provide and furnish screws, bolts, expansions shields or other fasteners to facilitate the proper installation of products, not furnished as part of the Integrated Door Assembly. 1.4 WARRANTY A. Provide

7、manufacturers standard five-year limited warranty against defects in material and workmanship unless noted otherwise. 1. Door Closers: 10 years Provided by IHSNot for Resale-,-,-03-01-12 08 17 10-2 2. Steel Pinned Continuous Hinges: 10 years 1.5 SUBMITTALS A. Submit shop drawings with proposed Integ

8、rated Door Assembly system, product and hardware options, in a timely manner to obtain the approval from architect in time to meet construction schedule of other trades. B. Provide for each door an frame location; frame type, profile, and installation details, items of finish hardware accessories, f

9、inishes, degree of opening and electrical rough-in requirements. Submit required templates to door and frame manufacturers to enable proper and accurate sizing and locations of hardware. C. Samples: Provide physical samples as required by Section 01 33 23. D. Provide Owner Manual, instruction sheets

10、 and installation. 1.6 DELIVERY, STORAGE AND HANDLING A. Integrated Door Assembly systems shall be delivered to the general contractor at the job site complete with necessary screws, miscellaneous parts, instructions, and installation templates. Each package shall be legibly and properly labeled to

11、correspond to the approved door schedule. B. Deliver Integrated Door Assembly system to project site. Contractor will jointly check in hardware with representatives of the supplier to verify shipment is correct and / or note and rectify discrepancies promptly. C. Furnish door assemblies with flush o

12、perating hardware flush with door skin, using protective wrappings and protective spacers between projecting hardware. Maintain and protect door assemblies using cardboard spacers and protective edge guards along the door edges, to reduce exposure to marring or damage during storage. D. Store door a

13、ssemblies in a dry and secure area. Storage area shall be void of any excess humidity that can cause damage to the product. 1.7 APPLICABLE PUBLICATIONS A. The following references established standards for architectural hardware as specified in this section. B. American National Standards Institute

14、(ANSI) ICC/ANSI A117.1-2003 . Accessible and Usable Buildings and Facilities ANSI/BHMA A156.1-2006 Butts and Hinges ANSI/BHMA A156.3-2008 Exit Devices ANSI/BHMA A156.4-2008 Door Controls - Closers Provided by IHSNot for Resale-,-,-03-01-12 08 17 10-3 ANSI/BHMA A156.5-2001 Auxiliary Locks and Associa

15、ted Products ANSI/BHMA A156.6-2005 Architectural Door Trim ANSI/BHMA A156.7-2009 Template Hinge Dimensions ANSI/BHMA A156.8-2005 Door Controls - Overhead Holders ANSI/BHMA A156.10-2005 . Power Operated Pedestrian Doors ANSI/BHMA A156.13-2002 . Mortise Locks and Latches ANSI/BHMA A156.15-2006 . Close

16、r Holder Release Devices ANSI/BHMA A156.16-2008 . Auxiliary Hardware ANSI/BHMA A156.18-2006 . Materials and Finishes ANSI/BHMA A156.19-2007 . Power Assist and Low Energy Power Operated Doors ANSI/BHMA A156.21-2009 . Thresholds ANSI/BHMA A156.22-2005 . Door Gasketing Systems ANSI/BHMA A156.23-2004 .

17、Electromagnetic Locks ANSI/BHMA A156.24-2003 . Delayed Egress Locking Systems ANSI/BHMA A156.25-2007 . Electrified Locking Devices ANSI/BHMA A156.26-2006 . Continuous Hinges ANSI/BHMA A156.28-2007 . Master Keying Systems ANSI/BHMA A156.29-2007 . Exit Locks and Alarms ANSI/BHMA A156.30-2003 . High Se

18、curity Cylinders ANSI/BHMA A156.31-2007 . Electric Strikes and Frame Mounted Actuators ANSI/BHMA A156.32-2008 . Integrated Door Opening Assemblies ANSI/SDI A250.4-2001 . Test Procedure and Acceptance Criteria for Physical Evidence for Steel Doors, Frames, Frame Anchors and Reinforcings ANSI/SDI A250

19、.8-2003 . Recommended Specifications for Standard Steel Doors and Frames ANSI/SDI A250.11-2001 Recommended Erection Instructions for Steel Frames UL10C-2009 . Positive Pressure Fire Tests of Door Assemblies C. American Society for Testing and Materials (ASTM) 1. ASTM E2074 (2000): Standard Test Meth

20、od for Fire Tests of Door Assemblies 2. ASTM E2180 (2007): Standard Test Method for Determining the Activity of Incorporated Antimicrobial Agent(s) In Polymeric or Hydrophobic Materials Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS03-01-12 08 17 10-4 3

21、. ASTM F476 (2002): Standard Test Method for Security of Swinging Door Assemblies D. Door and Hardware Institute (DHI) 1. Recommended Locations for Builders Hardware for Standard Doors and Frames (2004) 2. Recommended Locations for Builders Hardware for Custom Steel Doors and Frames (1996) E. Metal

22、Door and Frame Associations 1. Hollow Metal Manufacturing Association (HMMA) a. National Association of Architectural Metal Manufacturers (NAAMM) 2. Steel Door Institute (SDI) F. Approved Testing Laboratories 1. Underwriters Laboratories, Inc. (UL) a. UL305 (2007): Panic Hardware b. UL1784 (2004): A

23、ir Leakage Tests of Door Assemblies 2. ITS / Intertek Testing Services / Warnock Hersey Inc. G. National Fire Protection Association (NFPA) 1. NFPA 70-2008: National Electrical Code 2. NFPA 80-2010: Standard for Fire Doors and Other Opening Protectives 3. NFPA 101-2009: Life Safety Code 4. NFPA 105-

24、2010: Standard for Installation of Smoke Door Assemblies and Other Opening Protectives 5. NFPA 252-2008: Standard Methods of Fire Tests of Door Assemblies H. Building Codes Applicable Building Code 1. 2009 International Building Code 2. All hardware shall comply with UFAS, (Uniform Federal Accessibl

25、e Standards - 1998) unless specified otherwise PART 2 PRODUCTS 2.1 MATERIAL REQUIREMENTS A. Integrated Door Assembly requirements: 1. Comply with ANSI/BHMA A156.32a: Grade 1:1,000,000 2. Integrated Door Opening Assemblies shall provide a label for life safety or fire labels as required in door sched

26、ule. 3. Integral vision lite provided with door assembly, or field installed lite kit, as required. B. Door Frame requirements: 1. Door Frames shall be / 16 /14 /-gauge ASTM A366, cold roll steel Provided by IHSNot for Resale-,-,-03-01-12 08 17 10-5 and shall comply to ANSI/SDI A250.8 Level A Grade

27、III and / or HMMA/NAAMM 850-99. 2. Door frames shall be furnished with mitered corners, continuously welded, ground smooth on frame face. 3. Prepare frames with 14 gauge reinforcements for applied hardware. Provide 12 gauge reinforcements for continuous hinges. 4. Provide suitable adjustable type an

28、chors, minimum 4 per jamb. C. Integrated Hardware Requirements: 1. Provide a complete Integrated Door Assembly including the installation and adjustment of the latching mechanism within the door construction. The exit device shall be inset in door, clean and unobtrusive in design. The push bar shall

29、 comply with ANSI/BHMA Grade 1 Standard for exit devices. End caps shall be metal, plated satin nickel (BHMA 619). The Push and Pull devices shall be clean and unobtrusive in design. Lever handles shall be clean and unobtrusive in design with and shall match style of other hardware furnished on proj

30、ect. Continuous hinges shall comply with ANSI/BHMA A156.26. a. At doors with plastic laminate faces, provide hinges with wrap-around hinge guards and provide stainless steel wrap-around edge guards at the leading edge of the door. Hinges shall comply with ANSI/BHMA A156.26 2.2 FINISHES A. Finish Sym

31、bols US BHMA DESCRIPTION OF FINISH USP 600 Primed for field painting US26D 626/652 Satin Chrome US28 628 Satin Aluminum US32 629 Bright Stainless US32D 630 Satin Stainless N/A 689 Aluminum Painted B. Finish Requirements 1. Door Faces: / Prime / Factory Pre-Finished / Plastic Laminate / 2. Frames: /

32、Prime / Factory Pre-Finished / 3. Door Hardware: a. Continuous Hinges: 630 b. Push Bar: 630 clad with 619 end caps c. Lever Exit Device Trim: 630 Provided by IHSNot for Resale-,-,-03-01-12 08 17 10-6 d. Push/Pull Trim: 626 e. Door Closers: 689 f. Miscellaneous: To match other finishes /4. Anti-micro

33、bial Coating: All hand-operated hardware (levers, pulls, push bars, push plates, paddles, and panic bars) shall be provided with an anti-microbial/anti-fungal coating that has passed ASTM E2180 tests. Coating to consist of ionic silver (Ag+). Silver ions surround bacterial cells, inhibiting growth o

34、f bacteria, mold, and mildew by blockading food and respiration supplies./ PART 3 EXECUTION 3.1 EXAMINATION A. Contractor is responsible for notification of any wall conditions or building structure that would prevent proper execution of the installation of products produced in accordance with appro

35、ved hardware schedule. B. Note short or damaged deliveries on the bill of lading at the time of delivery. C. The fire label is a manufacturers certification only. Proper installation of products and proper wall construction are requirements to meet fire label. D. Unless otherwise required in other s

36、ections of the contract specs, provide power supply as required per the manufacturers installation instructions. E. Do not fabricate any product until receipt of approved submittal drawings. F. Beginning of installation means acceptance of existing conditions. 3.2 INSTALLATION A. Mount furnished har

37、dware accessories at heights indicated in “Recommended Locations or Builders Hardware” for Standard Doors and Frames, Custom Steel Doors and Frames, established by the Door and Hardware Institute (DHI), except if otherwise indicated or to comply with requirements of governing regulations, or if othe

38、rwise directed by the architect. B. Install furnished hardware accessories in compliance with the manufacturers instructions, templates and recommendations. Comply with specified degree of opening for doors with automatic operators, overhead door closers, etc. Securely fasten all furnished parts. Ma

39、ke sure all operating parts move freely and smoothly without binding, Provided by IHSNot for Resale-,-,-03-01-12 08 17 10-7 sticking and void of any excessive clearance. C. Coordinate installation and interface wiring with fire alarm and smoke detection systems. Provide all additional auxiliary cont

40、acts, relays, or interface for the fire alarm and security system D. Remove or protect furnished hardware accessories, prior to any painting or finishing that is to be completed after the installation of the hardware accessories. 3.3 ADJUSTMENT AND CLEANING A. Adjust and check door assembly and each

41、 operating item of hardware to ensure correct operation and function. Units which cannot be adjusted to operate as intended for the application made shall be replaced. B. Final Adjustment: Wherever hardware installation is made more than a month prior to building acceptance or occupancy of a space o

42、r area, the installer shall return to the work during the week prior to acceptance or occupancy and make final check and adjustment of all hardware items. Hardware Accessories shall be cleaned as necessary to restore correct operation, function, and finish. Do not use cleaners that will harm finish.

43、 3.4 PROTECTION A. Whenever furnished hardware accessories are located in areas where it may be subject to damage during construction by handling, cleaning, etc., (e.g. painting, cleaning of bricks) it shall be protected and/or removed from its location until the hazardous condition is terminated. 3

44、.5 SCHEDULES: A. The following is a general listing of the Integrated Door Assembly requirements and is not intended for use as a final door submittal. Any items of hardware required by established standards or practices, or to meet federal building codes shall be furnished whether or not specifical

45、ly called out in the following listed groups. HW-6D Each ADO Integrated Door to Have: RATED 1 Steel Frame 1 Integrated Door w/Exit Device Q2131 x TYPE 8 ELECTRIC DEVICE (E04) x F08 LEVER 1 Continuous Transfer Hinge A51031B x 8-THRUWIRE TRANSFER x IN-HINGE ACCESS PANEL Provided by IHSNot for ResaleNo

46、 reproduction or networking permitted without license from IHS03-01-12 08 17 10-8 1 Power Supply BY EXIT DEVICE MFR. FOR E04 FUNCTION 1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICKNESS 1 Floor Stop L02121 x 3 FASTENERS 1 Set Self-Adhesive Seals R0E154 EACH ADO INTEGRATED DOOR TO HAVE: POWER TRANSF

47、ER SHARED BY ELECTRIC PANIC AND RE-ACTIVATION SENSOR WIRING (RE-ACTIVATION SENSORS PROVIDED BY SECTION 08 71 13). KEY CYLINDER BY SECTION 08 71 00, DOOR HARDWARE. AUTO DOOR OPERATOR AND CONTROLS BY SECTION 08 71 13, AUTOMATIC DOOR OPERATORS. HW-8 Each MHO Pair Integrated Doors to Have: RATED 1 Steel

48、 Frame 1 Integrated Pair Doors w/Auto Flush Bolts & Push/Pull Trim Q2241 x TYPE 25 LESS BOTTOM BOLT AUTO FLUSH BOLT (INACTIVE LEAF) x ACTIVE CONCEALED VERTICAL LATCH (ACTIVE LEAF) 2 Continuous Hinges A51031B x WIDE THROW AS REQUIRED TO ACHIEVE FULL DOOR SWING 1 Coordinator TYPE 21A 1 Self-Adhesive A

49、stragal R0Y_14 2 Closers C02011 (PT4D, PT4H) x 180 SWING 2 Magnetic Holders C00011 TRI-VOLTAGE 1 Set Self-Adhesive Seals R0E154 POWER, WIRING, CONDUIT, AND FIRE ALARM CONNECTION BY DIVISION 26. HW-12A Each MHO Pair Integrated Doors to Have: RATED 1 Steel Frame 1 Integrated Pair Doors w/Exit Devices and Pull Trim Q2231 x TYPE 8 EXIT DEVICES (F01 / ACTIVE FLUSH PULL PASSAGE TRIM) 2 Continuous Hinges A5

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1