1、11-11 09 68 21 - 1 SECTION 09 68 21 ATHLETIC CARPETING SPEC WRITER NOTE: Delete between / _ / if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. Areas that have this floor are VAMC MULTI-PURPOSE and PHYSICAL THERAPY (ACTIV

2、ITY) rooms. PART 1 - GENERAL 1.1 DESCRIPTION: This section specifies carpet like soft surface flooring, and constructed monolithically to provide good traction designed to cushion accidental falls. 1.2 RELATED WORK: A. Color and texture of flooring and edge strips: Section 09 06 00, SCHEDULE FOR FIN

3、ISHES. B. Wall Base: Section 09 65 13, RESILIENT BASE AND ACCESSORIES. 1.3 QUALITY ASSURANCE: Installed flooring by using skilled craftsmen trained and approved by the manufacturer. 1.4 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Samples: 1

4、 Flooring, 300 mm (12 inches) square, each color and texture. 2. Plastic edge strip, 150 mm (6 inches) long, each color. C. Manufacturers Certificates: 1. Certificates stating flame spread and smoke development rating of the flooring. 2. Certificate approving type of adhesive, leveling compound and

5、 seam sealers. 3. Certificate approving installers qualifications specified. D. Manufacturers Literature and Data: Maintenance and cleaning manual. E. Shop Drawings: Layout plan showing seams and cuts. SPEC WRITER NOTE: Update Applicable Publications to correct issue at time of project specification

6、 preparation. 1.5 APPLICABLE PUBLICATIONS: A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS

7、11-11 09 68 21 - 2 B. American Society for Testing and Materials (ASTM): E84-10 . Surface Burning Characteristics of Building Materials E648-10 Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source E662-09 Special Optical Density of Smoke Generated by Solid Material

8、s C. American Association of Textile Chemists and Colorists (AATCC): 134-11 . Electrostatic Propensity of Carpets PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which

9、applies to the project. 2.1 SOFT SURFACE FLOORING: A. Flooring shall have following characteristics: Surface Fiber Content 100 percent continuous filament soil-hiding nylon with static control. Surface Fiber Height 3 mm (0.128 inch). Surface Weight Per Square Foot 2.44 ounces Interliner 120 g per m2

10、 (0.39 ounce per square foot) olefin. Fusion Coat 900 g per m2 (2.89 ounces per square foot). Vinyl Back Plate: 80s Compression set maximum 5 percent. Width 1800 mm (6 feet). Total Weight Per m2 (Square Foot) 3000 g (9.44 oz). B. Flame spread rating of not greater than 75 when tested under ASTM E84

11、method and have a critical radiant flux value of not less than 0.45 watts per square centimeter when tested under ASTM E648 method. C. Smoke development rating of not greater than 200 when tested under ASTM E662 method. D. Not build up a static level exceeding 3.0 KV when tested under AATCC 134 meth

12、od. 2.2 ADHESIVE, SEAM SEALERS AND SEAM CLEANERS: Types recommended by flooring manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 09 68 21 - 3 2.3 EDGE STRIPS Resilient butt type, with integral 38 mm (1-1/2 inch) wide base and 6 mm

13、1/4 inch) lip. Top surface to finish flush with flooring and lip beveled. PART 3 - EXECUTION SPEC WRITER NOTE: Edit to suit material of subfloor. 3.1 SURFACE PREPARATION: A. Subfloor shall be level and smooth. Level subfloor with approved leveling compound. /B. Concrete slabs shall be cured, and dr

14、y (not less than 60 days). / /C. Curing compounds, hardeners or sealers shall not be used on the slab. If a curing compound, hardener or sealer has been used, all residue must be removed prior to installation of flooring. / D. Flooring over existing surface such as wood or resilient tile: install in

15、 accordance with manufacturers printed installation instructions. 3.2 FLOORING INSTALLATION A. Secure flooring to subfloor using adhesive applied as recommended by manufacturer. Follow manufacturers recommendations for matching pattern and texture directions. B. Cut openings in flooring where requir

16、ed for installing equipment, pipes, outlets, and the like. Bind cut edges and replace flanges or plates. Use additional adhesive to anchor flooring around pipes and other vertical projections. C. Lay flooring lengthwise in longest dimension of space, and with minimum seaming area, uniformly to provi

17、de a tight smooth finish. Flooring shall be free from movement when subjected to traffic. D. Seaming: Use a special adhesive system that permanently welds the seams together. Adhesive shall be permanently resistant to cleaning solutions. Seams shall not be visible after flooring is installed. 3.3 ED

18、GE STRIP INSTALLATION: A. Install edge strips over exposed edges of flooring. B. Anchor strips to floor with suitable fasteners. C. Apply adhesive to edge strips, insert flooring into lip and press lip down over flooring. 3.4 PROTECTION AND CLEANING: A. Remove waste, strips, fasteners and other cutt

19、ings from flooring. Vacuum flooring and provide suitable protection. Unnecessary traffic will not be permitted on unprotected soft surface flooring. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 09 68 21 - 4 B. Just before final acceptance of work, remove protection and vacuum clean soft surface flooring. - - - E N D - - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI INCITS150-1987 Business Machines Data Processing Equipment and Business Forms - Character and Line Spacing《商务机、数据处理设备和商务表格.字符和行间距》.pdf ANSI INCITS150-1987 Business Machines Data Processing Equipment and Business Forms - Character and Line Spacing《商务机、数据处理设备和商务表格.字符和行间距》.pdf
  • ANSI INCITS182-1990 Guideline for Bar Code Print Quality《条码印刷质量指南》.pdf ANSI INCITS182-1990 Guideline for Bar Code Print Quality《条码印刷质量指南》.pdf
  • ANSI INCITS199-1991 Information Systems - 356-mm Optical Disk Cartridge (Write-Once) - Test Methods for Media Characteristics《信息系统.356毫米一次性可写盒式光盘.介质特性试验方法》.pdf ANSI INCITS199-1991 Information Systems - 356-mm Optical Disk Cartridge (Write-Once) - Test Methods for Media Characteristics《信息系统.356毫米一次性可写盒式光盘.介质特性试验方法》.pdf
  • ANSI INCITS231-1994 Information Systems - Fibre Distributed Data Interface (FDDI) - Physical Layer Protocol (PHY-2)《信息系统.光纤分布式数据接口(FDDI).物理层协议(PHY-2)》.pdf ANSI INCITS231-1994 Information Systems - Fibre Distributed Data Interface (FDDI) - Physical Layer Protocol (PHY-2)《信息系统.光纤分布式数据接口(FDDI).物理层协议(PHY-2)》.pdf
  • ANSI INCITS239-1994 Information Systems - Fibre Distributed Data Interface (FDDI) - Token Ring Media Access Control-2 (MAC-2)《信息系统.光纤分布式数据接口(FDDI).令牌网媒体访问控制-2(MAC-2)(以前为ANSI X3.239.pdf ANSI INCITS239-1994 Information Systems - Fibre Distributed Data Interface (FDDI) - Token Ring Media Access Control-2 (MAC-2)《信息系统.光纤分布式数据接口(FDDI).令牌网媒体访问控制-2(MAC-2)(以前为ANSI X3.239.pdf
  • ANSI INCITS241-1994 Data Compression Method Adaptive Coding with Sliding Window for Information Interchange《数据压缩法.信息交换用带滑动窗的自适应编码》.pdf ANSI INCITS241-1994 Data Compression Method Adaptive Coding with Sliding Window for Information Interchange《数据压缩法.信息交换用带滑动窗的自适应编码》.pdf
  • ANSI INCITS249-1995 Unrecorded Magnetic Tape Cartridge for Information Interchange 0.25 in (6.35 mm) 10 000 - 14 700 ftpi (394 579 ftpmm) Coercivity 550 oersteds (44 000 amperes me.pdf ANSI INCITS249-1995 Unrecorded Magnetic Tape Cartridge for Information Interchange 0.25 in (6.35 mm) 10 000 - 14 700 ftpi (394 579 ftpmm) Coercivity 550 oersteds (44 000 amperes me.pdf
  • ANSI INCITS254-1994 Information Technology - Fibre Channel - Mapping to HIPPI-FP (FC-FP) Replaces ANSI X3.254-1994《信息技术.光纤信道映射到HIPPI-FC(FC-FP)(以前为ANSI X3.254-1994 (R1999))》.pdf ANSI INCITS254-1994 Information Technology - Fibre Channel - Mapping to HIPPI-FP (FC-FP) Replaces ANSI X3.254-1994《信息技术.光纤信道映射到HIPPI-FC(FC-FP)(以前为ANSI X3.254-1994 (R1999))》.pdf
  • ANSI INCITS256-2007 Information technology - Radio Frequency Identification (RFID)《信息技术.射频识别(RFID)》.pdf ANSI INCITS256-2007 Information technology - Radio Frequency Identification (RFID)《信息技术.射频识别(RFID)》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1