1、01-11 10 26 00 - 1 SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between/ _/ If not applicable to project. Also delete any other item or paragraph not applicable to the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION This section specifies wall guards (cras

2、h rails or bumper guards), handrail/wall guard combinations, corner guards and door/door frame protectors / and high impact wall covering /. 1.2 RELATED WORK A. Structural steel corner guards: Section 05 50 00, METAL FABRICATIONS. B. Armor plates and kick plates not specified in this section: Sectio

3、n 08 71 00, DOOR HARDWARE. C. Color and texture of aluminum and resilient material: Section 09 06 00, SCHEDULE FOR FINISHES. 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: Show design and installation details. C. Manufacturer

4、s Literature and Data: 1. Handrail/Wall Guard Combinations. 2. Wall Guards. 3. Corner Guards. 4. Door/Door Frame Protectors. /5. High Impact Wall covering/ D. Test Report: Showing that resilient material complies with specified fire and safety code requirements. 1.4 DELIVERY AND STORAGE A. Deliver m

5、aterials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer. B. Protect from damage from handling and construction operations before, during and after installation. C. Store in a dry environment of approximately 21 C (70 degrees F)

6、for at least 48 hours prior to installation. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-11 10 26 00 - 2 1.5 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to extent referenced. Publications are referenc

7、ed in text by basic designation only. B. American Society for Testing and Materials (ASTM): A167-99(R2009)Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip B221-08.Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes D256-06.Impact Resistance of Plastics

8、D635-06.Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position E84-09Surface Burning Characteristics of Building Materials C. The National Association of Architectural Metal Manufacturers (NAAMM): AMP 500-06Metal Finishes Manual D. National Fire Protec

9、tion Association (NFPA): 80-10.Standard for Fire Doors and Windows E. Society of American Automotive Engineers (SAE): J 1545-05.Instrumental Color Difference Measurement for Exterior Finishes. F. Underwriters Laboratories Inc. (UL): Annual IssueBuilding Materials Directory PART 2 - PRODUCTS SPEC WRI

10、TER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 2.1 MATERIALS A. Stainless Steel: ASTM A167, Type 302B. B. Aluminum Extruded: ASTM B221, Alloy 6063, Temper T5 or T6

11、. / Aluminum alloy used for colored anodizing coating shall be as required to produce specified color. / C. Resilient Material: 1. Extruded and injection molded acrylic vinyl or extruded polyvinyl chloride meeting following requirements: Provided by IHSNot for ResaleNo reproduction or networking per

12、mitted without license from IHS-,-,-01-11 10 26 00 - 3 a. Minimum impact resistance of 1197 ps (25 ft lbs per sq.ft) when tested in accordance with ASTM D256 (Izod impact, ft.lbs. per inch notch). b. Class 1 fire rating when tested in accordance with ASTM E84, having a maximum flame spread of 25 and

13、 a smoke developed rating of 450 or less. c. Rated self extinguishing when tested in accordance with ASTM D635. d. Material shall be labeled and tested by Underwriters Laboratories or other approved independent testing laboratory. e. Integral color with all colored components matched in accordance w

14、ith SAE J 1545 to within plus or minus 1.0 on the CIE-LCH scales. f. Same finish on exposed surfaces. 2.2 CORNER GUARDS A. Resilient, Shock-Absorbing Corner Guards: / Flush mounted / Surface mounted / type of / 30 mm (1-1/4 inch radius) / 6 mm 1/4-inch corner) / formed to profile shown. 1. Snap-on c

15、orner guard formed from resilient material, minimum 2 mm (0.078-inch) thick, free floating on a continuous 1.6 mm (0.063-inch) thick extruded aluminum retainer. / Design retainer used for flush mounted type to act as a stop for adjacent wall finish material. / Provide appropriate mounting hardware,

16、cushions and base plates as required. 2. Provide factory fabricated end closure caps at top and bottom of surface mounted corner guards. 3. Flush mounted corner guards installed on any fire rated wall shall maintain the fire rating of the wall. Provide fire test of proposed corner guard system to ve

17、rify compliance. a. Where insulating materials are an integral part of the corner guard system, the insulating materials shall be provided by the manufacturer of the corner guard system. b. All exposed metal in fire rated assemblies shall have a paintable finish. B. Stainless Steel Corner Guards: Fa

18、bricate of 1.6 mm (0.0625-inch) thick stainless steel. Form guards of dimensions and to contour shown. 2.3 WALL GUARDS AND HANDRAILS A. Resilient Wall Guards and Handrails: 1. Handrail/Wall Guard Combination: Snap-on covers of resilient material, minimum 2 mm (0.078-inch) thick, shall be free-floate

19、d on a continuous, extruded aluminum retainer, minimum 1.8 mm (0.072-inch) thick, anchored to wall at maximum 760 mm (30 inches) on center. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-11 10 26 00 - 4 2. Wall Guards (Crash Rails): Snap-on cover

20、s of resilient material, minimum 2.8 mm (0.110-inch) thick, shall be free-floated over 50 mm (two-inch) wide aluminum retainer clips, minimum 2.3 mm (0.090-inch) thick, anchored to wall at maximum 600 mm (24 inches) on center, supporting a continuous aluminum retainer, minimum 1.6 mm (0.062-inch) th

21、ick; or, shall be free-floated over a continuous extruded aluminum retainer, minimum 2.3 (0.090-inch) thick anchored to wall at maximum 600 mm (24 inches) on center. 3. Provide handrails and wall guards (crash rails) with prefabricated and closure caps, inside and outside corners, concealed splices,

22、 cushions, mounting hardware and other accessories as required. End caps and corners shall be field adjustable to assure close alignment with handrails and wall guards (crash rails). Screw or bolt closure caps to aluminum retainer. B. Aluminum Wall Guards: Extruded aluminum, closed tubular bumper as

23、sembly mounted on wall brackets as shown. 1. Provide wall bumper with factory fabricated end closure caps, and inside and outside corner assemblies, concealed splice plates, and other accessories standard with the manufacturer. 2. Fabricate tubular wall guards from material with a nominal wall thick

24、ness of 6 mm (0.250-inch), form grooves for and provide two strips of continuous polyvinyl chloride cushion bumper inserts. 3. Fabricate adjustable wall brackets from aluminum having a nominal wall thickness of 5 mm (0.20-inch). Fasten bumper to brackets with 6 mm (1/4-inch) diameter aluminum or sta

25、inless steel bolts with locknuts. C. Stainless Steel Wall Guards: Construct wall guard, including brackets, of minimum 4.75 mm (0.1875-inch) thick stainless steel to design shown. 2.4 DOOR AND DOOR FRAME PROTECTION A. Fabricate door and door frame protection items from vinyl acrylic or polyvinyl chl

26、oride resilient material, minimum 1.5 mm (0.060-inch) thick, for doors / and / 0.9 mm (0.035-inch) thick for door frames /, as shown. B. Coordinate/ door / and / door frame / protection material requirements with door and frame suppliers to insure fit for all components, and color as specified. C. P

27、rovide adhesive as recommended by resilient material manufacturer. 2.5 HIGH IMPACT WALL COVERING A. Fabricate from vinyl acrylic or polyvinyl chloride resilient material minimum 6mm (0.06 inch) thick designed specially for interior use. Provided by IHSNot for ResaleNo reproduction or networking perm

28、itted without license from IHS-,-,-01-11 10 26 00 - 5 B. Coordinate with door /guard rail/ protection material and supplier for proper fit, installation and color. C. Provide adhesive as recommended by the wall covering manufacturer. 2.6 FASTENERS AND ANCHORS A. Provide fasteners and anchors as requ

29、ired for each specific type of installation. B. Where type, size, spacing or method of fastening is not shown or specified, submit shop drawings showing proposed installation details. 2.7 FINISH A. In accordance with NAAMM AMP 500 series. B. Aluminum: 1. Exposed aluminum: / AAC22A31 /chemically etch

30、ed medium matte, with clear anodic coating, Class II Architectural, 0.4 mil thick. / AA-C22A32 / chemically etched medium matte with integrally colored anodic coating, Class II Architectural 0.4 mil thick. / 2. Concealed aluminum: Mill finish as fabricated, uniform in color and free from surface ble

31、mishes. C. Stainless Steel: NAAMM finish Number 4. D. Resilient Material: Embossed texture and color in accordance with SAE J 1545 and as specified in Section 09 06 00, SCHEDULE FOR FINISHES. PART 3 - INSTALLATION 3.1 RESILIENT CORNER GUARDS Install corner guards on walls in accordance with manufact

32、urers instructions. 3.2 STAINLESS STEEL CORNER GUARDS Mount guards on external corners of interior walls, partitions and columns as shown. SPEC WRITER NOTE: Edit to suit type of guards specified and details shown on the drawings. B. Where corner guards are installed on walls, partitions or columns f

33、inished with plaster or ceramic tile, / anchor corner guards as shown on drawings. / Provide continuous 16 gage perforated, galvanized Z-shape steel anchors welded to back edges of corner guards and / wired to metal studs / expansion bolted to concrete or masonry with four 9.5 mm (3/8-inch) diameter

34、 bolts, spaced 400 mm (16 inches) on centers /. Coat back surfaces of corner guards, where shown, with a non-flammable, sound deadening material. Corner guards shall overlap finish plaster surfaces. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-

35、11 10 26 00 - 6 1. Where corner guards are installed on exposed structural glazed facing tile units or masonry wall, partitions or columns, / anchor corner guards as shown on the drawings / anchor corner guards to existing walls with 6 mm (1/4-inch) oval head stainless steel countersunk expansion or

36、 toggle bolts / anchor corner guards with four nominal 1.3 mm (0.0516-inch) thick, adjustable galvanized steel anchors, spaced as shown. / Grout spaces solid between guards and backing with Portland cement and sand mortar. 2. Where corner guards are installed on gypsum board, clean surface and ancho

37、r guards with a neoprene solvent-type contact adhesive specifically manufactured for use on gypsum board construction. Remove excess adhesive from around edge of guard and allow to cure undisturbed for 24 hours. 3.3 RESILIENT HANDRAIL / WALL GUARD COMBINATIONS / AND RESILIENT WALL GUARDS (CRASH RAIL

38、) / Secure guards to walls with / mounting cushions / brackets / and fasteners in accordance with manufacturers details and instructions. 3.4 ALUMINUM WALL GUARDS Secure brackets to walls with fasteners, spaced in accordance with manufacturers installation instructions. 3.5 STAINLESS STEEL WALL GUAR

39、DS Space brackets at not more than three feet on centers and anchor to the wall in accordance with manufacturers installation instructions. 3.6 DOOR, DOOR FRAME PROTECTION AND HIGH IMPACT WALL COVERING A. Surfaces to receive protection shall be clean, smooth and free of obstructions. B. Install prot

40、ectors after frames are in place but preceding installation of doors in accordance with approved shop drawings and manufacturers specific instructions. C. Apply with adhesive in controlled environment according to manufactures recommendations. D. Protection installed on fire rated doors and frames s

41、hall be installed according to NFPA 80 and installation procedures listed in UL Building Materials Directory; or, equal listing by other approved independent testing laboratory establishing the procedures. - - - E N D - - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文