1、05-11 14 24 00-1 SECTION 14 24 00 HYDRAULIC ELEVATORS SPEC WRITER NOTE: Delete between /_/ if not applicable to project. Delete items or paragraphs content not applicable and write “not used“ after title. PART 1 GENERAL 1.1 DESCRIPTION A. This section specifies the engineering, furnishing, and insta

2、llation of the complete electric hydraulic elevator system as described herein and as indicated on the contract drawings. B. Items listed in the singular apply to each and every elevator in this specification except where noted. SPEC WRITER NOTE: Edit Subparagraphs C, D and E to suit the project. C.

3、 Passenger Elevators No. P-_, P-_, shall be oil hydraulic type with microprocessor based control, / two stop automatic operation / single car selective collective automatic operation / duplex selective collective automatic operation / and power-operated / single-speed / two-speed / side opening / ce

4、nter opening / car and hoistway doors. Elevators shall have Class “A” loading. D. Service Elevators No. S-_, S-_, shall be oil hydraulic type with microprocessor based control, / two stop automatic operation / single car selective collective automatic operation / duplex selective collective automati

5、c / and power operated / single-speed / two speed / side opening / center opening / car and hoistway doors. Elevators shall have Class / “A” / “C1” / “C2” / “C3” / loading. E. Freight Elevators number F-_, F-_, shall be oil hydraulic type with microprocessor based control, / two stop automatic opera

6、tion / single car selective collective automatic operation / duplex selective collective automatic operation / and / manually operated / power operated / vertical bi-parting hoistway doors and car gate. Elevator shall have Class / “C1” / “C2” / “C3” / loading. 1.2 RELATED WORK A. Section 01 33 23 SP

7、ECIFICATIONS AND DRAWINGS FOR CONSTRUCTION (FAR 52.236-21) and, SPECIAL NOTES (VAAR 852.236-91), in GENERAL CONDITIONS. B. Section 07 84 00, FIRESTOPPING: Sealing around penetrations to maintain the integrity of fire-rated construction. Provided by IHSNot for ResaleNo reproduction or networking perm

8、itted without license from IHS-,-,-05-11 14 24 00-2 C. SECTION 09 06 00, SCHEDULE FOR FINISHES: As a master format for construction projects, to identify interior and exterior material finishes for type, texture, patterns, color and placement. D. Section 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR

9、NON-STRUCTURAL COMPONENTS: Requirements for seismic restraint of non-structural components. E. Section 26 05 11, REQUIREMENTS FOR ELECTRICAL INSTALLATIONS: General electrical requirements that are common to more than one section. F. Section 26 05 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLE

10、S (600 VOLTS AND BELOW): Low Voltage power and lighting wiring. G. Section 26 05 26, GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS: Requirements for personnel safety and to provide a low impedance path for possible ground fault currents. H. Section 26 05 33, RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS:

11、Conduits for cables and wiring. I. Section 26 05 71, ELECTRICAL SYSTEM PROTECTIVE DEVICE STUDY: Requirements for installing the over-current protective devices to ensure proper equipment and personnel protection. J. Section 26 22 00, LOW-VOLTAGE TRANSFORMERS: Low voltage transformers. K. Section 26

12、24 16, PANELBOARDS: Low voltage panelboards. L. Section 26 43 13, TRANSIENT-VOLTAGE SURGE SUPPRESSION: Surge suppressors installed in panelboards. M. Section 26 51 00, INTERIOR LIGHTING: Fixture and ballast type for interior lighting. N. VA Barrier Free Design Handbook (H-18-13) 1.3 QUALIFICATIONS A

13、. Approval by the Contracting Officer is required for products or services of proposed manufacturers, suppliers and installers and shall be contingent upon submission by Contractor of a certificate stating the following: 1. Elevator contractor is currently and regularly engaged in the installation o

14、f elevator equipment as one of his principal products. 2. Elevator contractor shall have three years of successful experience, trained supervisory personnel, and facilities to install elevator equipment specified herein. 3. The installers shall be Certified Elevator Mechanics with technical qualific

15、ations of at least five years of successful experience and Apprentices actively pursuing certified mechanic status. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-11 14 24 00-3 Certificates are required for all workers employed in this capacity.

16、4. Elevator contractor shall submit a list of two or more prior hospital installations where all the elevator equipment he proposes to furnish for this project functioned satisfactorily to serve varying hospital traffic and material handling demands. Provide a list of hospitals that have the equipme

17、nt in operation for two years preceding the date of this specification. Provide the names and addresses of the Medical Centers and the names and telephone numbers of the Medical Center Administrators. B. Approval of Elevator Contractors equipment will be contingent upon their identifying an elevator

18、 maintenance service provider that shall render services within / one hour / two hours / four hours / of receipt of notification, together with certification that the quantity and quality of replacement parts stock is sufficient to warranty continued operation of the elevator installation. C. Approv

19、al will not be given to elevator contractors and manufacturers who have established on prior projects, either government, municipal, or commercial, a record for unsatisfactory elevator installations, have failed to complete awarded contracts within the contract period, and does not have the requisit

20、e record of satisfactorily performing elevator installations of similar type and magnitude. D. All hydraulic elevators shall be the product of the same manufacturer. E. The Contractor shall provide and install only those types of safety devices that have been subjected to tests witnessed and certifi

21、ed by an independent professional testing laboratory that is not a subsidiary of the firm that manufactures supplies or installs the equipment. F. Welding at the project site shall be made by welders and welding operators who have previously qualified by test as prescribed in American Welding Societ

22、y Publications AWS Dl.1 to perform the type of work required. VAMC shall require welding certificates be submitted for all workers employed in this capacity. A welding or hot work permit is required for each day and shall be obtained from the COTR of safety department. Request permit one day in adva

23、nce. 1.4 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification. Elevator installation shall meet the requirements of the latest editions published and adopted by the United States Department of Veterans Affairs on the date contract is signed. Provided by IHSNot f

24、or ResaleNo reproduction or networking permitted without license from IHS-,-,-05-11 14 24 00-4 B. Federal Specifications (Fed. Spec.): J-C-30B Cable and Wire, Electrical (Power, Fixed Installation) W-C-596F . Connector, Plug, Electrical; Connector, Receptacle, Electrical W-F-406E . Fittings for Cabl

25、e, Power, Electrical and Conduit, Metal, Flexible HH-I-558C Insulation, Blankets, Thermal (Mineral Fiber, Industrial Type) W-F-408E . Fittings for Conduit, Metal, Rigid (Thick- Wall and Thin-wall (EMT) Type) RR-W-410 . Wire Rope and Strand TT-E-489J Enamel, Alkyd, Gloss, Low VOC Content QQ-S-766 Ste

26、el, Stainless and Heat Resisting, Alloys, Plate, Sheet and Strip C. International Building Code (IBC) D. American Society of Mechanical Engineers (ASME): A17.1 Safety Code for Elevators and Escalators A17.2 Inspectors Manual for Electric Elevators and Escalators E. National Fire Protection Associati

27、on: NFPA 13Standard for the Installation of Sprinkler Systems NFPA 70National Electrical Code (NEC) NFPA 72National Fire Alarm and Signaling Code NFPA 101.Life Safety Code NFPA 252.Fire Test of Door Assemblies F. American Society for Testing and Materials (ASTM): A1008/A1008M-09 Steel, Sheet, Cold R

28、olled, Carbon, Structural, High-Strength Low-Alloy and High Strength Low-Alloy with Improved Farability E1042-02 . Acoustically Absorptive Materials Applied by Trowel or Spray G. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS): SP-58 Pipe Hangers and Supports H. Societ

29、y of Automotive Engineers, Inc. (SAE) J517-91 .Hydraulic Hose, Standard I. Gages: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-11 14 24 00-5 For Sheet and Plate: U.S. Standard (USS) For Wires: American Wire Gauge (AWG) J. American Welding Socie

30、ty (AWS): D1.1 . Structured Welding Code Steel K. National Electrical Manufacturers Association (NEMA): LD-3 . High-Pressure Decorative Laminates L. Underwriters Laboratories (UL): 486A . Safety Wire Connectors for Copper Conductors 797 Safety Electrical Metallic Tubing M. Institute of Electrical an

31、d Electronic Engineers (IEEE) N. Regulatory Standards: Uniform Federal Accessibility Standards Americans with Disabilities Act 1.5 SUBMITTALS A. Submit in accordance with Specification Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, and SAMPLES. B. Before execution of work, furnish information to evi

32、dence full compliance with contract requirements for proposed items. Such information shall include, as required: Manufacturers Name, Trade Names, Model or Catalog Number, Nameplate Data (size, capacity, and rating) and corresponding specification reference (Federal or project specification number a

33、nd paragraph). All submitted drawings and related elevator material shall be forwarded to the Contracting Officer. C. Shop Drawings: 1. Complete scaled and dimensioned layout in plan and section view showing the arrangement of equipment and all details of each and every elevator unit specified inclu

34、ding: a. Complete layout showing location of storage tank/pump assembly, controller, piping layout, outside diameter of cylinder/plunger assembly, size of car platform, car frame members, and support assembly. b. Car, guide rails, brackets, buffers, and other components located in hoistway. c. Rail

35、bracket spacing and maximum vertical forces on guide rails in accordance with ASME A17.1 Section 2.23 and Section 8.4.8 for Seismic Risk Zone 2 or greater. d. Reactions at points of supports and buffer impact loads. e. Weights of principal parts. Provided by IHSNot for ResaleNo reproduction or netwo

36、rking permitted without license from IHS-,-,-05-11 14 24 00-6 f. Top and bottom clearances and over travel of the car. g. Location of shunt trip circuit breaker, switchboard panel, light switch, and feeder extension points in the machine room. 2. Drawings of hoistway entrances and doors showing deta

37、ils of construction and method of fastening to the structural members of the building. a. If drywall construction is used to enclose hoistway, submit details of interface fastenings between entrance frames and drywall. b. Sill details including sill support. D. Samples: 1. One each of stainless stee

38、l, 75 mm x 125 mm (3 in. x 5 in.). 2. One each of baked enamel, 75 mm x 125 mm (3 in. x 5 in.). 3. One each of color vinyl floor tile. 4. One each of protection pads, 75 mm x 125 mm (3 in. x 5 in.) if used. 5. One each car and hoistway Braille plate sample. 6. One each car and hall button sample. 7.

39、 One each car and hall lantern/position indicator sample. 8. One each wall and ceiling material finish sample. 9. One each car lighting sample. 10. No other samples of materials specified shall be submitted unless specifically requested after submission of manufacturers name. If additional samples a

40、re furnished pursuant to request, adjustment in contract price and time will be made as provided in Section 00 72 00, GENERAL CONDITIONS. E. Name of manufacturer, type or style designation, and applicable data of the following equipment shall be shown on the elevator layouts: 1. Storage tank/pump as

41、sembly. 2. Pump and motor, HP and RPM rating, Voltage, Starting and Full Load Ampere, Number of phases, and Gallons per minute. 3. Controller 4. Starters and Overload Current Protection Devices. 5. Car Safety Device; Rupture Valve and Manual Shut Off Valves. 6. Electric Door Operator; HP rating and

42、RPM of motor. 7. Hoistway Door Interlocks. 8. Car Buffers; maximum and minimum rated load, maximum rated striking speed and stroke. 9. Cab Ventilation Unit; HP rating and CFM rating. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-11 14 24 00-7 F.

43、 Complete construction drawings of elevator car enclosure, showing dimensioned details of construction, fastenings to platform, car lighting, ventilation, ceiling framing, top exits, and location of car equipment. G. Complete dimensioned detail of vibration isolating foundations for storage tank/pum

44、p assembly. H. Dimensioned drawings showing details of: 1. All signal and operating fixtures. 2. Car slide guides/roller guides. 3. Hoistway door tracks, hangers, and sills. 4. Door operator, infrared curtain units. I. Cuts or drawings showing details of controllers and supervisory panels. J. Furnis

45、h certificates as required under: Paragraph “QUALIFICATIONS“. 1.6 WIRING DIAGRAMS A. Provide three complete sets of field wiring and straight line wiring diagrams showing all electrical circuits in the hoistway, machine room and fixtures. Install one set coated with an approved plastic sealer and mo

46、unted in the elevator machine room as directed by the Resident Engineer. B. In the event field modifications are necessary during installation, diagrams shall be revised to include all corrections made prior to and during the final inspection. Corrected diagrams shall be delivered to the Resident En

47、gineer within 30 days of final acceptance. C. Provide the following information relating to the specific type of microprocessor controls installed: 1. Owners information manual, containing job specific data on major components, maintenance, and adjustment. 2. System logic description. 3. Complete wi

48、ring diagrams needed for field troubleshooting, adjustment, repair and replacement of components. Diagrams shall be base diagrams, containing all changes and additions made to the equipment during the design and construction period. 4. Changes made during the warranty period shall be noted on the dr

49、awings in adequate time to have the finalized drawings reproduced for mounting in the machine room no later than six months prior to the expiration of the warranty period. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-11 14 24 00-8 1.7 ADDITIONAL EQUIPMENT A. Additional eq