BS 7671-2001 电气设备的要求 IEE布线规则 .pdf

上传人:周芸 文档编号:115196 上传时间:2019-07-07 格式:PDF 页数:6 大小:71.79KB
下载 相关 举报
BS 7671-2001 电气设备的要求 IEE布线规则 .pdf_第1页
第1页 / 共6页
BS 7671-2001 电气设备的要求 IEE布线规则 .pdf_第2页
第2页 / 共6页
BS 7671-2001 电气设备的要求 IEE布线规则 .pdf_第3页
第3页 / 共6页
BS 7671-2001 电气设备的要求 IEE布线规则 .pdf_第4页
第4页 / 共6页
BS 7671-2001 电气设备的要求 IEE布线规则 .pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS 7671 : 2001Amendment No 1 : 2002(AMD 13628)Requirements forElectrical InstallationsIEE Wiring RegulationsSixteenth EditionCopies may be obtained from The Institutions web site:http:/www.iee.org/TechnicalThe Institution of Electrical Engineers,P.O. Box 96, STEVENAGE,United Kingdom

2、. SG1 2SDTel: +44 (0)1438 767 328 Fax: +44 (0)1438 742 792Email: salesiee.org.uk BSI AND THE INSTITUTION OF ELECTRICAL ENGINEERS 2002NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSIONAmendment No 1, (AMD 13628)February 2002标准分享网 免费标准下载站 ContentsIntroduction to Amendment No 1 (AMD 13628) to BS 7671 :

3、2001 2TABLE 4A1 Schedule of Installation Methods of Cables (including Reference Method) 4TABLE 4A2 Schedule of appropriate current rating tables 4TABLE 4D1A Single-core 70 C thermoplastic (pvc) insulated cables, non-armoured, with or without标准分享网 免费标准下载站 sheath (COPPER CONDUCTORS) 5TABLE 4D5A 70 C t

4、hermoplastic (pvc) insulated and sheathed flat cable with protective conductor(COPPER CONDUCTORS) 6Introduction to Amendment No 1 (AMD 13628) to BS 7671 : 2001Amendment No 1 to BS 7671 : 2001 provides table ratings specifically for UK National Type insulated and sheathedflat twin cables with protect

5、ive conductor (Table 4D5A). These ratings are generally greater than those ratingsgiven in Table 4D2A.Regulation 433-02-04 is amended to require the ratings of ring circuit cables to be not less than 20 A instead of 0.67 In.Other, generally editorial, changes have been made.This amendment comes into

6、 effect on 1st February 2002.Published by: The Institution of Electrical Engineers, LONDON 1992, 1994, 1997, 2000, 2001, 2002 Institution of Electrical Engineers and British Standards InstitutionAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system or trans

7、mitted inany form or by any means - electronic, mechanical, photocopying, recording or otherwise - without the prior writtenpermission of the publisher.G19CDBS 7671 : 2001 Amendment No 1 (AMD 13628) 2Amend 433-02-04 as follows.433-02-04 For a ring final circuit protected by a 30 A or 32 A protective

8、 device complying with BS 88, BS 1361,BS 3036, BS EN 60898, BS EN 60947-2 or BS EN 61009-1 (RCBO) and supplying accessories to BS 1363 andwired with copper conductors, the minimum cross-sectional area of both phase and neutral conductors is 2.5 mm2except for two-core mineral insulated cables to BS 6

9、207 for which the minimum is 1.5 mm2. Such ring final circuitsare deemed to meet the requirements of Regulation 433-02-01 if the current-carrying capacity (Iz) of the cable is notless than 0.67 times the rated current or the current setting (In) of the protective device 20 A, and if, under theintend

10、ed conditions of use, the load current in any part of the ring is unlikely to exceed for long periods thecurrent-carrying capacity (Iz) of the cable.Reason: to require that the current carrying capacity of ring circuit cables be not less than 20 A and to requirethat the load current in any part of r

11、ing final circuits is unlikely to exceed Izfor long periods, seeRegulation 433-01-01.Amend 604-02-02(i) and (ii) as follows.标准分享网 免费标准下载站 G19CDBS 7671 : 2001 Amendment No 1 (AMD 13628) 3604-02-02(i) 25 V, 1 phase, SELV - portable hand lamps in confined or damp locations(ii) 50 V, 1 phase, SELV porta

12、ble hand lamps in confined or damp locationsDeleted by BS 7671 : 2 , Amendment No 1.Reason: to correct an editorial error.Amend 607-02-02 as follows.607-02-02 Equipment having a protective conductor current exceeding 3.5 mA but not exceeding 10 mA, shalleither be permanently connected to the fixed w

13、iring of the installation without the use of a plug and socket-outlet orconnected by means of a connector plug and socket complying with BS EN 60309-2.Reason: to correct an error.Amend Appendix 4, Contents as follows.COPPER CONDUCTORS70 C THERMOPLASTIC (PVC) INSULATED CABLES4D1 Single-core non-armou

14、red, with or without sheath4D2 Multicore non-armoured4D3 Single-core armoured (non-magnetic armour)4D4 Multicore armoured4D5 Flat cable with protective conductorReason: to include Table 4D5A added by the amendment.Amend Table 4A1 as follows.TABLE 4A1Schedule of Installation Methods of Cables (includ

15、ing Reference Method)Installation methodNumber DescriptionExamplesAppropriate ReferenceMethod for determiningcurrent-carrying capacity12 3 4标准分享网 免费标准下载站 G19CDBS 7671 : 2001 Amendment No 1 (AMD 13628) 46Sheathed cables inconduit in a thermallyinsulating wall etc.(otherwise as ReferenceMethod 4)Metho

16、d 4 orMethod 6 for cable typecovered by Table 4D5A.15Sheathed cables installeddirectly in a thermallyinsulating wall or above athermally insulatingceiling, the cable being incontact with a thermallyconductive surface on oneside (otherwise asReference Method 4)Method 4 orMethod 15 for cable typecover

17、ed by Table 4D5A.Reason: to include Table 4D5A added by the amendment. Note, bold font is used because the Method is also aReference Method.Amend Table 4A2, BS 6004 as follows.TABLE 4A2Schedule of appropriate current rating tablesSpecificationNumberSpecification Title ApplicableCurrent RatingTablesC

18、onductorOperatingTemperatureBS 6004 : 2000Electric cables. PVC insulated, non-armoured cables forvoltages up to and including 450/750 V, for electric power,lighting and internal wiring.PVC insulated and sheathed flat cable with protectiveconductor to Table 84D1, 4D24E14D570 oC, 90 oC70 oCReason: to

19、include Table 4D5A added by the amendment.Amend Table 4D1A, 2.5 mm2conductor, column 2 as follows.TABLE 4D1ASingle-core 70 C thermoplastic (pvc) insulated cables, non-armoured, with or without sheath(COPPER CONDUCTORS)123(mm2) (A) (A)11.51114.510.513.52.54619.5 202634182431Reason: to recognise the i

20、ncreased current carrying capacities of UK National Type insulated and sheathed flattwin cables with protective conductor.Add a new table 4D5A as follows.Reason: to recognise the increased current carrying capacities of UK National Type insulated and sheathed flattwin cables with protective conducto

21、r.标准分享网 免费标准下载站 G19CDBS 7671 : 2001 Amendment No 1 (AMD 13628) 5G19CD6TABLE 4D5AAmbient temperature: 30 Cor operating temperature: 70 CVoltage drop(per ampere per metre)5(A) (mV/A/m)16204429273747648518117.34.42.8NOTES:1. Where the conductor is to beprotected by a semi-enclosed fuse toBS 3036, see i

22、tem 6.2 of the prefaceto this appendix.2. * These methods are regarded asReference Methods for the cabletypes specified by the table.标准分享网 免费标准下载站 BS 7671 : 2001 Amendment No 1 (AMD 13628)70 C thermoplastic (pvc) insulated and sheathed flat cable with protective conductor(COPPER CONDUCTORS)BS 6004 T

23、able 8CURRENT-CARRYING CAPACITY (amperes): ConductConductorInstallation Method 6*(Enclosed in conduit inan insulated wall)Installation Method 15*(Installed directly in aninsulated wall)Reference Method 1(clipped direct)cross-sectionalarea1 two-core cable,single-phase a.c. or d.c.12 34(mm2) (A) (A)11.511.514.512152.546101620263244572127354763

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > BS

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1