IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf

上传人:sumcourage256 文档编号:1235575 上传时间:2019-08-24 格式:PDF 页数:6 大小:127.75KB
下载 相关 举报
IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf_第1页
第1页 / 共6页
IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf_第2页
第2页 / 共6页
IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf_第3页
第3页 / 共6页
IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf_第4页
第4页 / 共6页
IEC 60939-2 CORR 1-2005 Passive filter units for electromagnetic interference suppression - Part 2 Sectional specification Passive filter units for which safety tests are appropria.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、November 2005 IEC 60939-2 (Second edition 2005) Passive filter units for electromagnetic interference suppression Part 2: Sectional specification: Passive filter units for which safety tests are appropriate Test methods and general requirements CORRIGENDUM 1 Page 10 1.5.2 Replace the existing text b

2、y the following: The filter shall be clearly marked with the information in 1.5.1 a), b), c), d) and f), and also e) if this is not implied by b). Page 19 4.4.2 Applied voltage Replace the first sentence by the following: The voltages given in Table 9 shall be applied between the measuring points of

3、 Table 3 of IEC 60939-1 for a period of 1 min for qualification approval and periodic testing and for a period of 2 s for lot-by-lot quality conformance testing. Page 21 4.7 Insertion loss Replace the first phrase by the following: See 4.7 of IEC 60939-1 with the following details: Page 21 4.8 Disch

4、arge resistance Replace the first sentence by the following: See 4.8 of IEC 60939-1. Page 22 4.9 Robustness of terminations Replace the first phrase by the following: See 4.9 of IEC 60939-1 with the following details: November 2005 Page 22 4.10 Resistance to soldering heat Replace the second sentenc

5、e by the following: See 4.10 of IEC 60939-1 with the following details: Page 22 4.11 Solderability Replace the second sentence by the following: See 4.11 of IEC 60939-1, with the following details: Page 22 4.11.2 Requirements Replace the first sentence by the following: See 4.11.2, 4.11.3 and 4.11.4

6、 of IEC 60939-1. Page 22 4.12 Rapid change of temperature Replace the first sentence by the following: See 4.12 of IEC 60939-1 with the following details: Page 23 4.13 Vibration Replace the first sentence by the following: See 4.13 of IEC 60939-1 with the following details: Page 23 4.14 Bump Replace

7、 the second sentence by the following: See 4.14 of IEC 60939-1 with the following details: November 2005 Page 24 4.15 Shock Replace the second sentence by the following: See 4.15 of IEC 60939-1 with the following details: Page 24 4.16 Container sealing Replace the second sentence by the following: S

8、ee 4.16 of IEC 60939-1 with the following details: Page 25 4.17 Climatic sequence Replace the first sentence by the following: See 4.17 of IEC 60939-1 with the following details: Page 25 4.17.1 Initial measurements Replace the first sentence by the following: The initial measurements for the climati

9、c sequence are the measurements made in 4.10.2, 4.14.2 or 4.15.2 as appropriate. Page 25 4.17.2 Dry heat Replace the first sentence by the following: See 4.17.2 of IEC 60939-1 with the following details: Page 25 4.17.3 Damp heat, cyclic, first cycle Replace the first sentence by the following: See 4

10、.17.3 of IEC 60939-1. November 2005 Page 25 4.17.4 Cold Replace the first sentence by the following: See 4.17.4 of IEC 60939-1 with the following details: Page 25 4.17.5 Low air pressure Replace the second sentence by the following: See 4.17.5 of IEC 60939-1 with the following details: Page 25 4.17.

11、6 Damp heat, cyclic, remaining cycles Replace the first sentence by the following: See 4.17.6 of IEC 60939-1. Page 25 4.17.7 Final inspection, measurements and requirements Replace the first sentence by the following: See 4.17.7 of IEC 60939-1, with the following details: Page 26 4.18 Damp heat, ste

12、ady state Replace the first sentence by the following: See 4.18 of IEC 60939-1 with the following details: Page 26 4.19 Temperature rise Replace the third sentence by the following: See 4.19 of IEC 60939-1 with the following details: November 2005 Page 28 4.20.2 Test conditions Replace the first two

13、 sentences by the following: Filters shall be submitted to an impulse voltage test except for filters with capacitors of subclasses X3 and Y3. Each individual filter shall be subjected to a maximum of 24 impulses of the same polarity. Page 29 4.20.3 Requirements Replace, throughout this subclause, t

14、he word capacitor by the word filter. Page 29 4.21 Endurance Replace the second sentence by the following: See 4.21 of IEC 60939-1 with the following details: Page 31 4.22 Charge and discharge Replace the second sentence by the following: See 4.22 of IEC 60939-1 with the following details: Page 32 4

15、.23 Passive flammability Replace the second sentence by the following: See 4.23 of IEC 60939-1. Page 32 4.24 Current overload Replace the second sentence by the following: See 4.20 of IEC 60939-1. November 2005 Page 32 4.25 Solvent resistance of the marking Replace the second and third sentences by

16、the following: See 4.25 of IEC 60939-1. The requirements are as in 4.25 of IEC 60939-1. Page 33 4.26 Component solvent resistance Replace the second sentence by the following: See 4.26 of IEC 60939-1. Page 33 4.27 Active flammability Replace the second sentence by the following: See 4.24 of IEC 60939-1.

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1