IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf

上传人:inwarn120 文档编号:1235893 上传时间:2019-08-24 格式:PDF 页数:16 大小:1,022KB
下载 相关 举报
IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf_第1页
第1页 / 共16页
IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf_第2页
第2页 / 共16页
IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf_第3页
第3页 / 共16页
IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf_第4页
第4页 / 共16页
IEC 61156-4-1-2009 Multicore and symmetrical pair quad cables for digital communications - Part 4-1 Riser cables - Blank detail specification《数字通信用多芯和对称二路 四路电缆.第4-1部分 吊索.空白详细规范》.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、 IEC 61156-4-1 Edition 3.0 2009-05 INTERNATIONAL STANDARD Multicore and symmetrical pair/quad cables for digital communications Part 4-1: Riser cables Blank detail specification IEC 61156-4-1:2009(E) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2009 IEC, Geneva, Switzerland All rights reserved.

2、 Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you

3、have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch

4、 Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept

5、under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical

6、 committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. Electrope

7、dia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Servi

8、ce Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC 61156-4-1 Edition 3.0 2009-05 INTERNATIONAL STAND

9、ARD Multicore and symmetrical pair/quad cables for digital communications Part 4-1: Riser cables Blank detail specification INTERNATIONAL ELECTROTECHNICAL COMMISSION M ICS 33.120.20 PRICE CODE ISBN 2-8318-1038-8 Registered trademark of the International Electrotechnical Commission 2 61156-4-1 IEC:20

10、09(E) CONTENTS FOREWORD.3 1 Scope.5 2 Normative references .5 3 Guidance for preparation of detail specifications 5 4 Blank detail specification for multicore and symmetrical pair(s)/quad(s) cables for digital communication in riser wiring .7 61156-4-1 IEC:2009(E) 3 INTERNATIONAL ELECTROTECHNICAL CO

11、MMISSION _ MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS Part 4-1: Riser cables Blank detail specification FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC

12、National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, P

13、ublicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- go

14、vernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IE

15、C on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are acce

16、pted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote internatio

17、nal uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the la

18、tter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its

19、directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses ar

20、ising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention i

21、s drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61156-4-1 has been prepared by subcommittee 46C: Wires and symmetric cables, o

22、f IEC technical committee 46: Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories This standard is to be read in conjunction with IEC 61156-1: 2002 and IEC 61156-4. This third edition of IEC 61156-4-1 cancels and replaces the second edition published in

23、2003. This edition constitutes a technical revision. The significant global technical change is the alignment with IEC 61156-4. 4 61156-4-1 IEC:2009(E) The text of this standard is based on the second edition and on the following documents: FDIS Report on voting 46C/885/FDIS 46C/893/RVD Full informa

24、tion on the voting for the approval of this standard can be found in the report on voting indicated in the above table. A list of all parts of the IEC 61156 series, under the general title Multicore and symmetrical pair/quad cables for digital communications, can be found on the IEC website. This pu

25、blication has been drafted in accordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific public

26、ation. At this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. 61156-4-1 IEC:2009(E) 5 MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS Part 4-1: Riser cables

27、Blank detail specification 1 Scope This blank detail specification relates to multicore and symmetrical pair/quad cables for digital communications in riser application. This blank detail specification determines the layout and style for detail specifications describing multicore and symmetrical pai

28、r(s)/quad(s) cables for digital communication in riser wiring. Detail specifications based on the blank detail specification may be prepared by a national standards organization, a manufacturer or a user. 2 Normative references The following referenced documents are indispensable for the application

29、 of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61156-1: 2002 1 , Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification

30、 IEC 61156-4, Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification ISO/IEC 11801, Information technology Generic cabling for customer premises 3 Guidance for preparation of detail specifications It is necessary to keep the transmission ch

31、aracteristics indicated in the relevant sectional specification for the category number (3 or 5) and the characteristic impedance. The detail specification shall be written in accordance with the layout of the blank detail specification which forms part of this standard. NOTE When a characteristic d

32、oes not apply, then NA (for not applicable) may be entered in the appropriate space. When a characteristic applies but a specific value is not considered necessary, then NS (for not specified) should be entered in the appropriate space. The numbers shown in brackets on this and the following pages c

33、orrespond to the following items of required information, which shall be entered in the spaces provided. 1 Name and address of the organization that has prepared the document. 2 IEC document number, issue number and date of issue. _ 1A more recent version of this standard exists (2007), but as not a

34、ll of the tests cited herein are addressed by the newer edition, it has been decided that the 2002 edition is to be used. 6 61156-4-1 IEC:2009(E) 3 Address of the organization from which the document is available. 4 Related documents. 5 Any other references to the cable, national reference, trade na

35、me, etc. 6 A complete description of the cable which shall include a) type and number of elements; b) nominal impedance; c) screening; d) application; e) category; f) other distinguishing performance characteristics. Example: 25-pair, unshielded twisted pair cable for use in riser wiring, having a n

36、ominal impedance of 100 , and meeting the transmission requirements of category 5 7 Details of the cable materials and construction. 8 Special requirements for bending radius or operation temperatures. 9 List of cable characteristics. They are separated into electrical, transmission, mechanical and

37、environmental characteristics. 10 Appropriate subclause references in the sectional specification IEC 61156-4: 2009. 11 Requirements applicable for this cable. The values entered shall at a minimum meet the requirements of the sectional specification IEC 61156-4: 2009. 12 Relevant remarks. 61156-4-1

38、 IEC:2009(E) 7 4 Blank detail specification for multicore and symmetrical pair(s)/quad(s) cables for digital communication in riser wiring 1 Prepared by: 2 Document: Issue: Date: 3 Available from: 4 Generic specification: IEC 61156-1:2002 Sectional specification: IEC 61156-4:2009 Blank detail specif

39、ication: IEC 61156-4-1: 2009 5 Additional references: 6 Cable description: IEC 61156-4: 2009 subclause comments 7Cable materials and construction 2.2.2 Cable construction 2.2.3 Conductor description 2.2.4 Insulation description: Nominal thickness Maximum diameter 2.2.5 Colour code of elements 2.2.6

40、Number of elements 2.2.7 Screening of the element 2.2.8 Cable make-up: Number of units: Screen of the units Tape material Minimum overlap Protective wrapping(s) of the cable core: 8 61156-4-1 IEC:2009(E) 2.2.9 Screening of the cable core: Tape material Minimum overlap Drain wire Braid wire Braid mat

41、erial Filling factor 2.2.10 Sheath: Material Nominal thickness Maximum overall diameter Marking Rip cord 2.2.11 Colour of the sheath 2.2.12 Identification 2.2.13 Packaging of finished cable 8 Minimum bending radius for static bending: mm Minimum bending radius for dynamic bending: mm Temperature ran

42、ge (installation/operation): C 61156-4-1 IEC:2009(E) 9 9 Characteristics 10 Subclause 11 Requirements 12 Comments Electrical characteristics 3.2 Conductor resistance 3.2.1 . /km Resistance unbalance 3.2.2 . % Dielectric strength 3.2.3 conductor/conductor kV conductor/screen kV Insulation resistance

43、3.2.4 conductor/conductor . Mkm conductor/screen . Mkm Mutual capacitance 3.2.5 . nF/km Capacitance unbalance 3.2.6 pair/screen . pF/500 m Transfer impedance at 1 MHz 10 MHz 100 MHz 3.2.7 . m/m . m/m . m/m Transmission characteristics 3.3 Velocity of propagation (phase velocity) 3.3.1 . km/s Phase d

44、elay 3.3.1.1 Differential phase delay 3.3.1.2 Environmental effects 3.3.1.2.2 Attenuation at 1 MHz 3.3.2 . dB/100 m 4 MHz . dB/100 m 10 MHz . dB/100 m 16 MHz . dB/100 m 20 MHz . dB/100 m 31,25 MHz . dB/100 m 62,5 MHz . dB/100 m 100 MHz . dB/100 m Unbalance attenuation near-end (TCL) 3.3.3 . dB Unbal

45、ance attenuation far-end (EL-TCTL) 3.3.3 . dB 10 61156-4-1 IEC:2009(E) 9 Characteristics 10 Subclause 11 Requirements 12 Comments Near-end crosstalk at 1 MHz 3.3.4 dB 4 MHz dB 10 MHz dB 16 MHz dB 20 MHz dB 31,25 MHz dB 62,5 MHz dB 100 MHz dB Specify: EL FEXT or IO FEXT measured at, or corrected to,

46、a length of 100 m at 1 MHz 4 MHz 10 MHz 16 MHz 20 MHz 31,25 MHz 62,5 MHz 100 MHz 3.3.5 dB dB dB dB dB dB dB dB Characteristic impedance Input impedance 1 MHz / . MHz Function fitted impedance/mean characteristic impedance 3.3.6 3.3.6.1 3.3.6.2 . 15 Structural return loss (SRL) 3.3.7 . dB Mechanical

47、characteristics 3.4 Dimensional requirements Insulation diameter Sheath thickness Cable diameter 3.4.1 mm Elongation at break of the conductors 3.4.2 % Elongation at break of the insulation 3.4.3 % Elongation at break of the sheath 3.4.4 % Tensile strength of the sheath 3.4.5 MPa 61156-4-1 IEC:2009(

48、E) 11 9 Characteristics 10 Subclause 11 Requirements 12 Comments Crush test of the cable 3.4.6 Impact test of the cable 3.4.7 Repeated bending of the cable 3.4.8 Tensile performance of the cable 3.4.9 N Environmental characteristics 3.5 Shrinkage of insulation 3.5.1 % Wrapping test of insulation after thermal ageing 3.5.2 Bending test of insulation at low temperature 3.5.3 Elongation at break of the sheath after ageing 3.5.4 % Initial value Tensile strength of the sheath after ageing 3.5.5 % Sheath pressure test at high temperature 3.5.6 Cold bend test

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1