1、 INTERNATIONAL STANDARD IEC 61169-37 QC 222400First edition 2007-02Radio-frequency connectors Part 37: Sectional specification STWX8 R.F. connectors Reference number IEC 61169-37:2007(E) Publication numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 seri
2、es. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment 1 and the b
3、ase publication incorporating amendments 1 and 2. Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Information relating to this publication, including its validity,
4、is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications is
5、sued, is also available from the following: IEC Web Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to search by a variety of criteria including text searches, technical committees and date of publication. On-line informati
6、on is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/online_news/ justpub) is also available by email. Please contact the Customer Service Centre (see below) for f
7、urther information. Customer Service Centre If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 22 919 02 11 Fax: +41 22 919 03 00 INTERNATIONAL STANDARD IEC 61169-37 QC 222400First edition 2007-0
8、2Radio-frequency connectors Part 37: Sectional specification STWX8 R.F. connectors IEC 2007 Copyright - all rights reserved No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in wri
9、ting from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch T For price, see current catalogue PRICE CODE Commission Electrotechnique Intern
10、ationale International Electrotechnical Commission 2 61169-37 IEC:2007(E) CONTENTS FOREWORD.3 1 Scope.5 2 Normative references .5 3 Mating face and gauge information.5 3.1 Dimensions - General connectors Grade 2 (Figure 1) .5 3.2 Gauges for general purpose connectors - Grade 2 7 3.3 Dimensions stand
11、ard test connectors Grade 0.10 4 Quality assessment procedure13 4.1 General .13 4.2 Rating and characteristics (see Clause 6 of IEC 61169-1 (QC 220000) 13 4.3 Test schedule and inspection requirements - Acceptance tests .16 4.4 Procedures19 5 Instructions for preparation of detail specifications .19
12、 5.1 General .19 5.2 Identification of the detail specification19 5.3 Identification of the component19 5.4 Performance20 5.5 Marking, ordering information and related matters.20 5.6 Selection of tests, tests conditions and severities20 5.7 Blank detail specification pro-forma for type STWX 8 connec
13、tors 20 Figure 1 Mating face of STWX8 connectors (for dimensions and notes, see Table 1) .6 Figure 2 Gauge pins for contact of socket connectors (for dimensions, see Table 2).8 Figure 3 Gauge for outer of socket connectors (for dimensions, see Table 3) 9 Figure 4 Female contact (for dimensions and n
14、otes, see Table 4)10 Figure 5 Male contact (for dimensions and notes, see Table 5)12 Table 1 Mating face dimensions.7 Table 2 Gauges Dimensions 8 Table 3 Gauge dimensions 10 Table 4 Female contact dimensions .11 Table 5 Male contact dimensions .12 Table 6 Rating and characteristics .14 Table 7 Accep
15、tance tests.16 Table 8 Periodic tests 17 61169-37 IEC:2007(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ RADIO-FREQUENCY CONNECTORS Part 37: Sectional specification STWX8 R.F. connectors FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardizatio
16、n comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes Internationa
17、l Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in thi
18、s preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two
19、 organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the
20、 form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterp
21、retation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national o
22、r regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of th
23、is publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or in
24、direct, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for
25、the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61169-37 has been p
26、repared by subcommittee 46F: R.F. and microwave passive components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories. The text of this standard is based on the following documents: CDV Report on voting 46F/44/CDV 46F/49/
27、RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. 4 61169-37 IEC:2007(E) A list of all parts of the IEC 61169 series, under the g
28、eneral title Radio frequency connectors, can be found on the IEC website. The QC numbers that appear on the front cover of this publication are the specification numbers in the IEC Quality Assessment System for Electronic Components (IECQ). The committee has decided that the contents of this publica
29、tion will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of th
30、is publication may be issued at a later date. 61169-37 IEC:2007(E) 5 RADIO-FREQUENCY CONNECTORS Part 37: Sectional specification STWX8 R.F. connectors 1 Scope This part of IEC 61169, which is a Sectional Specification (SS), provides information and rules for the preparation of Detail Specifications
31、(DS) for type STWX8 R.F. coaxial connectors with push-pull self-lock coupling. The connectors are normally used with flexible and semi-rigid R.F. cables for middle power applications in conjunction with 50 cables in an operating frequency range up to 4 GHz. It describes the interface dimensions for
32、general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from QC 220000 (IEC 61169-1), applicable to all DS relating to type STWX8 connectors. This specification indicates the recommended perform
33、ance characteristics to be considered when writing a DS and covers test schedules and inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated reference
34、s, the latest edition of the referenced document (including any amendments) applies. IEC 60096 (all parts), Radio-frequency cables IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods Amendment 1 (1996) Amendment 2 (1997) 3 Mating face
35、 and gauge information 3.1 Dimensions - General connectors Grade 2 (Figure 1) All dimensions are in mm. All un-dimensioned pictorial configurations are for reference purpose only. 6 61169-37 IEC:2007(E) Note 1 J D F H C B A G E N P Note 1 Note 1 Note 1 U S I T X C Z W K 90 10 L M BB Q EE Q M M A L M
36、 CC DD AA Note 1 Note 4 V Q R IEC 300/07 Figure 1 Mating face of STWX8 connectors (for dimensions and notes, see Table 1) 61169-37 IEC:2007(E) 7 Table 1 Mating face dimensions mm Reference min. max. Notes A 8,12 8,20 Diameter B 4,83, - Diameter C 2,06 2,21 Diameter D 4,0 - E 5,33 5,84 F - 0,18 G 4,5
37、 - H - 0,18 I 8,22 8,28 Diameter J 6,90 7,00 K - 2,20 L 0,05 0,15 Radius M - 0,13 Radius N - 0,64 Diameter P 1,32 1,37 Diameter Q 0,19 0,25 R 0,00 0,30 S 7,05 - T - - Diameter (see Note 2) U 7,05 - V 6,00 - W 0,18 - X - 4,72- Diameter Z 0,18 - AA - - Diameter (see Note 3) BB 7,92 8,02 Diameter CC 1,
38、22 1,42 DD 0,72 0,92 EE 1,10 Nominal NOTE 1 Reference plane: mechanical and electrical. NOTE 2 To meet electrical and mechanical requirements. NOTE 3 Bore diameter closed to meet electrical and mechanical requirements when mated with a 1,32/1,37 diameter. 3.2 Gauges for general purpose connectors -
39、Grade 2 All dimensions are in mm. All undimensioned pictorial configurations are for reference purposes only. 8 61169-37 IEC:2007(E) 3.2.1 Gauges for socket contact 4 mm (max.) 3,17 mm (min.) 50 10 D C IEC 301/07 Figure 2 Gauge pins for contact of socket connectors (for dimensions, see Table 2) Tabl
40、e 2 Gauges Dimensions Gauge A- Maximum material for sizing purposes Gauge B Minimum material for measurement of gauge retention force Mass of gauge: (80 1) g mm mm Reference min. max. min. max. D 1,370 1,375 1,315 1,320 C 0 0,64 - - Material: steel, polished. Surface roughness: Ra=0,4 m maximum. Tes
41、t procedure According to 9.3.4 of IEC 61169-1, the gauge A shall be inserted three times into the socket center contact. This is a sizing operation. After this, the gauge B shall be inserted into socket centre contact. The contact shall support the mass of the gauge in a vertical downward attitude.
42、NOTE The minimum diameter of gauge A corresponds to the maximum diameter of a male contact. 61169-37 IEC:2007(E) 9 3.2.2 Gauges for female outer contact Radius or allow chamfer 0,38 mm (max.) Jack connector center contact/insulator into the hole A J Reference plane IEC 302/07 (A) General dimensions
43、Q M M A 90 10 Reference plane Reference plane L M Q BB K L M DD Q CC IEC 303/07 (B) Alternative coupling grooves Figure 3 Gauge for outer of socket connectors (for dimensions, see Table 3) 10 61169-37 IEC:2007(E) Table 3 Gauge dimensions Gauge C-Maximum material for sizing purpose Gauge D-Minimum ma
44、terial for measurement of gauge retention force mm mm Reference min. max. min. max. A 8,185 8,20 8,12 8,135 J 7,05 7,15 7,05 7,15 K 1,1 1,1 Rad.L 0,05 0,15 0,05 0,15 RadM - 0,13 - 0,13 Q 0,2 0,25 0,15 0,20 BB 7,95 7,98 7,95 7,98 CC 1,2 1,4 1,1 1,3 DD 0,6 0,8 0,5 0,7 Material: polished steel. Surface
45、 roughness: Ra =0,4 m max. Test procedure According to 9.3.4 of IEC 61169-1, the gauge C shall be placed three times inside the outer contact. This is a sizing operation. The gauge D is placed inside the outer contact.The retention force of the gauge shall be 15 N minimum. 3.3 Dimensions standard te
46、st connectors Grade 0 3.3.1 Socket (female contact) Note 1 J R D B Q A F H V C P Y Z Note 1 H E X W IEC 304/07 Figure 4 Female contact (for dimensions and notes, see Table 4) 61169-37 IEC:2007(E) 11 Table 4 Female contact dimensions mm Reference min. max. Notes A 8,22 8,25 Diameter B 4,67 4,72 see N
47、ote 3/Diameter C 2,16 2,18 see Note 4/Diameter D see Note 2/Diameter E 6 F 0,27 0,52 H 0,29 0,57 J 7,05 7,20 P 1,39 1,41 Diameter Q 7,78 7,82 R 0 0,30 V 2,13 2,18 Diameter W 4,62 4,88 X 6,05 6,10 Y 0,18 0,23 Z 0,15 0,25 NOTE 1 Reference plane: mechanical and electrical. NOTE 2 Diameter of outer cond
48、uctor and length of uniform section of transmission line to give required characteristic impedance of 50 when checked using time domain reflectometer methods. NOTE 3 Dimension for use of PTFE dielectric having a dielectric constant of 2,02. Use of PTFE is mandatory. NOTE 4 Bore diameter closed to meet electrical and mechanical requirements when mated with a 1,35/1,37 diameter. 12 61169-37 IEC:2007(E) Plug (male contact) Note 1 j f h r b a c d u Note 1 60 1 e n p IEC 305/07Figure 5 Male contact (for dimens