1、October 2011 Octobre 2011 IEC 61984 (2nd edition 2008) Connectors Safety requirements and tests CEI 61984 (2me dition 2008) Connecteurs Exigences de scurit et essais C ORRIGENDUM 1 6 Constructional requirements and performance 6.19.1.1 General On page 24, instead of: Clearances through slots and ope

2、nings in enclosures of insulating material shall meet the values of case A of Table F.2 of IEC 60664-1:2007 and/or Table 2 of IEC 60664-5:2007. read: Clearances through slots and openings in enclosures of insulating material shall meet the values of case A of IEC 60664- 1:2007 and/or IEC 60664-5:200

3、7. 6.19.2.1 General On page 24, instead of: Creepage distances shall be dimensioned according to the rated voltage according to IEC 60664-1 and/or Table 4 of IEC 60664- 5:2007, the pollution degree and insulating material as specified according to IEC 60664-1 and/or Table 4 of IEC 60664- 5:2007. If

4、the rated voltage is not derived from the nominal voltage of the supply system (see Table F.3a and Table F.3b of IEC 60664-1:2007) but from the working voltage, interpolation is permissible. For the relationship between creepage distance and clearances see 5.2.2.6 of IEC 60664-1:2007 and/or 5.3.2.6

5、of IEC 60664-5:2007. read: Creepage distances shall be dimensioned according to the rated voltage according to 6 Performances et exigences de construction 6.19.1.1 Gnralits En page 69, au lieu de: Les distances disolement travers les fentes ou ouvertures des enveloppes du matriau isolant doivent tre

6、 en accord avec les valeurs du cas A du Tableau F.2 de la CEI 60664-1:2007 et/ou du Tableau 2 de la CEI 60664-5:2007. lire: Les distances disolement travers les fentes ou ouvertures des enveloppes du matriau isolant doivent tre en accord avec les valeurs du cas A de la CEI 60664-1:2007 et/ou CEI 606

7、64-5:2007. 6.19.2.1 Gnralits En page 69, au lieu de: Les lignes de fuite doivent tre dimensionnes selon la tension assigne, conformment la CEI 60664-1 et/ou au Tableau 4 de la CEI 60664-5:2007, le degr de pollution et le matriau isolant, conformment la CEI 60664-1 et/ou au Tableau 4 de la CEI 60664-

8、5:2007. Si la tension assigne nest pas drive de la tension nominale du rseau dalimentation (voir Tableau F.3a et Tableau F.3b de la CEI 60664-1:2007) mais de la tension locale, linterpolation est autorise. Pour la relation entre la ligne de fuite et les distances disolement, voir 5.2.2.6 de la CEI 6

9、0664-1:2007 et/ou 5.3.2.6 de la CEI 60664-5:2007. lire: Les lignes de fuite doivent tre dimensionnes selon la tension assigne, October 2011 Octobre 2011 IEC 60664-1 and/or IEC 60664-5:2007, the pollution degree and insulating material as specified according to IEC 60664-1 and/or IEC 60664-5:2007. If

10、 the rated voltage is not derived from the nominal voltage of the supply system (see Table F.3a and Table F.3b of IEC 60664-1:2007) but from the working voltage, interpolation is permissible. For the relationship between creepage distance and clearances see 5.2.2.6 of IEC 60664-1:2007 and/or IEC 606

11、64-5:2007. conformment la CEI 60664-1 et/ou CEI 60664-5:2007, le degr de pollution et le matriau isolant, conformment la CEI 60664-1 et/ou CEI 60664-5:2007. Si la tension assigne nest pas drive de la tension nominale du rseau dalimentation (voir Tableau F.3a et Tableau F.3b de la CEI 60664-1:2007) mais de la tension locale, linterpolation est autorise. Pour la relation entre la ligne de fuite et les distances disolement, voir 5.2.2.6 de la CEI 60664-1:2007 et/ou CEI 60664-5:2007.

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1