IEC 62209-2 CORR 1-2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part.pdf

上传人:progressking105 文档编号:1237278 上传时间:2019-08-24 格式:PDF 页数:2 大小:127.75KB
下载 相关 举报
IEC 62209-2 CORR 1-2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part.pdf_第1页
第1页 / 共2页
IEC 62209-2 CORR 1-2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、June 2010 Juin 2010 IEC 62209-2 (First edition 2010) Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices Human models, instrumentation, and procedures Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devi

2、ces used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) CEI 62209-2 (Premire dition 2010) Exposition humaine aux champs radiofrquence produits par les dispositifs de communications sans fils tenus la main ou ports prs du corps Modles de corps humain, instrumentation et pro

3、cdures Partie 2: Procdure de dtermination du dbit dabsorption spcifique produit par les appareils de communications sans fil utiliss trs prs du corps humain (gamme de frquences de 30 MHz 6 GHz) CORRIGENDUM 1 5.2.2 Phantom material, shape and size In the third paragraph, item b), instead of: Except f

4、or frequencies above 300 MHz and read: For frequencies above 300 MHz and 5.2.2 Matriau, forme et taille du fantme Dans le troisime alina, item b), au lieu de: Except pour les frquences suprieures 300 MHz et lire: Pour les frquences suprieures 300 MHz et June 2010 Juin 2010 6.1.4.6 Body-supported dev

5、ice In the second paragraph, instead of: then the screen-side will not need to be tested if it ordinarily remains 200 mm from the body. Where a screen mounted antenna is present, this position shall be repeated with the screen against the flat phantom as shown in Figure 7a) (right side), if this is

6、consistent with the intended use. read: then the screen-side will not need to be tested if the antenna(s) integrated in it ordinarily remain(s) 200 mm from the body. Where a screen mounted antenna is present, the measurement shall be performed with the screen against the flat phantom as shown in Fig

7、ure 7a) (right side), if operating the screen against the body is consistent with the intended use. 6.1.4.6 Appareil pos sur le corps Dans le deuxime alina, au lieu de : il nest pas ncessaire de soumettre essai le ct de lcran sil reste gnralement 200 mm du corps. En prsence dune antenne intgre lcran

8、 cette position doit tre rpte en plaant lcran contre le fantme plan comme reprsent la Figure 7a) ( droite), si cela est cohrent avec lutilisation prvue. lire: il nest pas ncessaire de soumettre essai le ct de lcran si lantenne qui lui est intgre reste gnralement 200 mm du corps. En prsence dune antenne intgre lcran, la mesure doit tre ralise en plaant lcran contre le fantme plan comme reprsent la Figure 7a) ( droite), si lutilisation de lcran contre le corps est cohrente avec lutilisation prvue.

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1