IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf

上传人:fuellot230 文档编号:1238107 上传时间:2019-08-24 格式:PDF 页数:98 大小:2MB
下载 相关 举报
IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf_第1页
第1页 / 共98页
IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf_第2页
第2页 / 共98页
IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf_第3页
第3页 / 共98页
IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf_第4页
第4页 / 共98页
IEC TR 62649-2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices《高强度超声波治疗设备(HITU)的测量标准要求》.pdf_第5页
第5页 / 共98页
点击查看更多>>
资源描述

1、 IEC/TR 62649 Edition 1.0 2010-04 TECHNICAL REPORT Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices IEC/TR 62649:2010(E) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2010 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no

2、part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions about IEC cop

3、yright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune partie de cette publication ne peut tre reproduite n

4、i utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright de la CEI ou si vous dsirez obtenir des droits

5、 supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About IEC publications The technical content of IEC publica

6、tions is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, t

7、ext, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by em

8、ail. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online.

9、Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC/TR 62649 Edition 1.0 2010-04 TECHNI

10、CAL REPORT Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices INTERNATIONAL ELECTROTECHNICAL COMMISSION XD ICS 17.140.50 PRICE CODE ISBN 978-2-88910-922-7 Registered trademark of the International Electrotechnical Commission 2 TR 62649 IEC:2010(E) CONTENT

11、S FOREWORD.4 INTRODUCTION.6 1 Scope.7 2 Background 7 3 Limitations of existing standard methods 10 3.1 General .10 3.2 Very high pressures 11 3.3 Very high intensities11 3.4 Strong focusing .12 3.5 Nonlinear harmonics .12 3.6 Acoustic saturation and nonlinear loss 12 3.7 Relevant parameters .13 4 Su

12、rvey of experts .13 5 Existing literature for measurement of HITU fields 18 6 Discussion26 6.1 General .26 6.2 Measurement of power .26 6.3 Specification of field parameters related pressure and intensity distribution.27 6.4 Robust methodology for measuring pressure at a point .27 6.5 Direct measure

13、ment of intensity 28 6.6 Measurement of temperature rise and temperature distribution .28 6.7 Thermal dose 28 6.8 Cavitation activity30 6.9 Registration of the HITU field with the targeting system.30 6.10 Tissue-mimicking material for QA/engineering evaluation30 6.11 Electrical properties of the tra

14、nsducer .31 6.12 Treatment monitoring 31 6.13 Equipment safety and essential performance.31 6.14 Tissue properties.31 7 Recommendations32 7.1 Items for immediate development32 7.1.1 General .32 7.1.2 Measurement of total output power as an International Standard or as an amendment to IEC 61161 Ed.2

15、in TC 87 32 7.1.3 Specification and measurement of field parameters as a Technical Specification (TS) in TC 8732 7.1.4 Equipment safety and essential performance as a Particular Standard in the 60601 series in TC 62.32 7.2 Items for development within 5 years.32 7.2.1 General .32 7.2.2 Robust method

16、 of measuring pressure.32 7.2.3 Measurement of temperature.33 7.2.4 Electrical properties of therapeutic transducers .33 7.2.5 Registration of the HITU field with the targeting system.33 7.2.6 Tissue-mimicking material for QA/engineering evaluation 33 7.3 Items requiring extensive further research.3

17、3 TR 62649 IEC:2010(E) 3 Annex A (informative) Detailed responses to questionnaire34 Annex B (informative) Definitions in selected ultrasound standards54 Annex C (informative) Chinese national standard.67 Bibliography87 Figure 1 Radiation force balance system using absorbing target (upward beam)77 F

18、igure 2 Radiation force balance system using different measuring system (downward beam) .78 Figure 3 Hydrophone scanning configuration for measuring HIFU acoustic field (upward beam)78 Figure 4 Hydrophone scanning measurement configuration for measuring HIFU acoustic field (downward beam)79 Figure 5

19、 Correction factor of plane wave for the acoustic field of a circular plane piston ultrasonic transducer82 Table 1 General characteristics of ultrasound used for different therapeutic applications 8 Table 2 International standards and related documents for the measurement of medical ultrasound field

20、s 9 Table 3 Questions and summarised answers .14 4 TR 62649 IEC:2010(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ REQUIREMENTS FOR MEASUREMENT STANDARDS FOR HIGH INTENSITY THERAPEUTIC ULTRASOUND (HITU) DEVICES FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organizat

21、ion for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC

22、publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with

23、may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agr

24、eement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC

25、 Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are use

26、d or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the co

27、rresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible f

28、or any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees

29、and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8)

30、 Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent righ

31、ts. IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee may propose the publication of a technical report when it has collected data of a different kind from t

32、hat which is normally published as an International Standard, for example “state of the art“. IEC 62649, which is a technical report, has been prepared by committee TC 87: Ultrasonics. The text of this technical report is based on the following documents: Enquiry draft Report on voting 87/420/DTR 87

33、/428/RVC Full information on the voting for the approval of this technical report can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. TR 62649 IEC:2010(E) 5 The committee has decided that the contents

34、 of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual versio

35、n of this publication may be issued at a later date. 6 TR 62649 IEC:2010(E) INTRODUCTION This Technical Report is concerned with standards for high intensity therapeutic ultrasound (HITU) and concentrates on applications that destroy tissue by heating which may or may not be accompanied by acoustic

36、cavitation and other mechanisms. The purpose of the report is to identify topics where there is a consensus that the development of international standards would benefit the industries and/or patients involved with these forms of therapeutic ultrasound. The shortcomings of existing standards as they

37、 may be related to the applications of interest are reviewed. It is not its purpose to propose or evaluate specific alternative measurement methods which may be more reliably applied to HITU or other therapeutic equipment. Physiotherapy and lithotripsy are excluded as there are existing standards fo

38、r these established uses. Lower intensity applications such as enhanced bone healing or ultrasound-induced gene therapy are not explicitly considered. The use of HITU has advanced to the point where systems have achieved clinical approval for general use in several countries. Medical applications an

39、d product development are continuing rapidly. The corresponding products of many companies have been approved for marketing and clinical applications. Fast development in preclinical medicine, clinic medicine, and product manufacture has created an urgent need to standardize measurements of the basi

40、c acoustic parameters and the field characteristics of HITU. In order to promote the further development of HITU and to ensure its safe and effective use, international standards are required. TR 62649 IEC:2010(E) 7 REQUIREMENTS FOR MEASUREMENT STANDARDS FOR HIGH INTENSITY THERAPEUTIC ULTRASOUND (HI

41、TU) DEVICES 1 Scope This technical report is relevant to the measurement and specification of ultrasound fields intended for medical therapeutic purposes. Lithotripsy and physiotherapy are excluded, since there are existing International Standards for these applications. It establishes: topics where

42、 there is a consensus that the development of International Standards would benefit the industries and/or patients; topics where the writing of standards should start immediately; topics where the writing of technical specifications should start immediately in order to gain practical experience and

43、establish consensus prior to standardisation; topics which require future standardisation but where further research is required before initiating the writing of standards or technical specifications. This report addresses primarily the requirements for measurement standards related to high intensit

44、y therapeutic ultrasound (HITU) also known as high intensity focused ultrasound (HIFU) fields which are both high intensity and focused and where the main mechanism for action is thermal. However, aspects of the discussion, conclusions and any resulting standards or technical specifications may also

45、 be relevant to therapeutic applications which are either focused or high intensity or where the main mechanism is not thermal. Scientific literature has been reviewed and responses to a questionnaire which was sent to experts around the world are reported. 2 Background Recent years have seen a dram

46、atic rise in interest in using ultrasound as a surgical and therapeutic tool in its own right. Much of this growth has been due to the use of High Intensity Therapeutic Ultrasound (HITU) for tissue ablation in the treatment of cancers and conditions such as benign prostate hyperplasia (BPH). Here, u

47、ltrasound is brought to a focus within tissue with the intention of generating intensity levels sufficient to raise the local tissue temperature above 55 C. Like so much in ultrasound, this technique was first tested many years ago (Lynn et al, 1942; Wall et al, 1951, Fry et al, 1954), but recent ma

48、terials, computing and other technological advances have allowed it to come close to the medical mainstream. The ability to generate such high temperatures within tissue brings with it the absolute requirement to ensure that the treatment is delivered to the correct level and at the correct site. Th

49、is in turn means that accurate methods of predicting the dose and monitoring performance are required. Consequently, reliable measurement and characterisation methods are needed for this application above all others. However, HITU is not the only therapeutic application. Ultrasound physiotherapy, of course, has been widely used since the 1950s (Imig et al, 1954; Gersten, 1955) and lithotripsy since 1980 (Chaussy et al) for the destruction of kidney stones. More experime

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1