IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf

上传人:feelhesitate105 文档编号:1238123 上传时间:2019-08-24 格式:PDF 页数:48 大小:3.99MB
下载 相关 举报
IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf_第1页
第1页 / 共48页
IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf_第2页
第2页 / 共48页
IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf_第3页
第3页 / 共48页
IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf_第4页
第4页 / 共48页
IEC TR 62713-2013 Safety procedures for reduction of risk outside a structure《构筑物外风险降低的安全型规程》.pdf_第5页
第5页 / 共48页
点击查看更多>>
资源描述

1、 IEC/TR 62713 Edition 1.0 2013-04 TECHNICAL REPORT RAPPORT TECHNIQUE Safety procedures for reduction of risk outside a structure Procdures de scurit pour la rduction des risques lextrieur dune structure IEC/TR 62713:2013 colour inside THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2013 IEC, Genev

2、a, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in th

3、e country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication con

4、traire, aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questi

5、ons sur le copyright de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Genev

6、a 20 infoiec.ch Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC

7、 publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: IEC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a variety of cri

8、teria (reference number, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available on-line an

9、d also once a month by email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotec

10、hnical Vocabulary (IEV) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la pre

11、mire organisation mondiale qui labore et publie des Normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldit

12、ion la plus rcente, un corrigendum ou amendement peut avoir t publi. Liens utiles: Recherche de publications CEI - www.iec.ch/searchpub La recherche avance vous permet de trouver des publications CEI en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Elle donne aussi des inform

13、ations sur les projets et les publications remplaces ou retires. Just Published CEI - webstore.iec.ch/justpublished Restez inform sur les nouvelles publications de la CEI. Just Published dtaille les nouvelles publications parues. Disponible en ligne et aussi une fois par mois par email. Electropedia

14、 - www.electropedia.org Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 30 000 termes et dfinitions en anglais et en franais, ainsi que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique Internationa

15、l (VEI) en ligne. Service Clients - webstore.iec.ch/csc Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions contactez-nous: csciec.ch. IEC/TR 62713 Edition 1.0 2013-04 TECHNICAL REPORT RAPPORT TECHNIQUE Safety procedures for reduction of risk outside a str

16、ucture Procdures de scurit pour la rduction des risques lextrieur dune structure INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE S ICS 91.120.40 PRICE CODE CODE PRIX ISBN 978-2-83220-744-4 Registered trademark of the International Electrotechnical Commission Marq

17、ue dpose de la Commission Electrotechnique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agr. colour inside 2 TR 62713 IEC:2013 CONTENTS FOREWORD . 3 INT

18、RODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 6 4 General 8 4.1 Introductory remark . 8 4.2 Lightning damage to human beings . 9 4.2.1 General . 9 4.2.2 Direct strikes . 9 4.2.3 Side flash 9 4.2.4 Touch or contact voltages 10 4.2.5 Step voltages 10 5 Effects of light

19、ning strikes to human beings 11 5.1 Possible injuries 11 5.2 How injured people can be helped . 12 6 How to act in the presence of a thunderstorm . 14 6.1 How to detect a lightning risk . 14 6.2 Where to find safe locations 14 6.3 What to do outdoors 15 6.4 Hazardous situation in a car 17 6.5 What t

20、o do when camping . 17 6.6 Thunderstorms in mountainous regions . 18 6.7 What to do on water 18 6.8 What to do at open air festivals . 19 6.9 What to do when playing outdoor sports 19 Bibliography 21 Figure 1 Examples of roofs and facades damaged by lightning 8 Figure 2 Direct strike 9 Figure 3 Side

21、 flash . 9 Figure 4 Unsuitability of metallic structures when not earthed 10 Figure 5 Electrization by touch voltage . 10 Figure 6 Current flow through body due to by step voltage . 11 Figure 7 Lichtenberg figures on human skin 1 12 Figure 8 Cardiopulmonary resuscitation (CPR). 13 Figure 9 How to av

22、oid strikes inside a house . 15 Figure 10 Avoid the highest point in this area . 16 Figure 11 Safety distance (10 m) under a tree . 16 Figure 12 Generally, a car acts as a Faraday cage 17 Figure 13 Example of a lightning protection system on a sailing boat . 19 TR 62713 IEC:2013 3 INTERNATIONAL ELEC

23、TROTECHNICAL COMMISSION _ SAFETY PROCEDURES FOR REDUCTION OF RISK OUTSIDE A STRUCTURE FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to

24、 promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Gu

25、ides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IE

26、C also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as

27、possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense

28、. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees under

29、take to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any atte

30、station of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition

31、of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct

32、or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable

33、 for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees

34、 is to prepare International Standards. However, a technical committee may propose the publication of a technical report when it has collected data of a different kind from that which is normally published as an International Standard, for example “state of the art“. IEC/TR 62713, which is a technic

35、al report, has been prepared by IEC technical committee 81: Lightning protection. The text of this technical report is based on the following documents: Enquiry draft Report on voting 81/427/DTR 81/429/RVC Full information on the voting for the approval of this technical report can be found in the r

36、eport on voting indicated in the above table. 4 TR 62713 IEC:2013 This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “h

37、ttp:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are consider

38、ed to be useful for the correct understanding of its contents. Users should therefore print this document using a colour printer. TR 62713 IEC:2013 5 INTRODUCTION IEC/TR 62713, which is a technical report, is informative, with the purpose of giving the lay person, i. e. a non-specialist in lightning

39、 protection and a non-medically trained person, appropriate action to reduce risk from lightning to people outside fixed structures, i. e. in a variety of everyday outdoor activities, including immediate action to take in the event of a person being injured by lightning. Part of these precautions in

40、cludes taking shelter in either a lightning protected structure or an unprotected structure. Any action in the long term to ensure that such structures are suitably protected should be designed by a lightning protection specialist based on the requirements of the appropriate parts of IEC 62305 as li

41、sted in the normative references of this report. It is not the purpose of this report to quantify the risk reduction achieved by taking the precautions suggested in it. 6 TR 62713 IEC:2013 SAFETY PROCEDURES FOR REDUCTION OF RISK OUTSIDE A STRUCTURE 1 Scope This technical report introduces lightning

42、to the layman, noting the right action in the presence of thunderstorms, as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. It should be noted that so far there are no means to avoid lightning. However, by following some element

43、ary rules, people can be protected against its deleterious effects. 2 Normative references None. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 aphasia inability to express thought in words or inability to understand thought as expressed in

44、spoken or written words or others 3.2 apnoea cessation of breathing, asphyxia 3.3 arrhythmia irregularity of the heartbeat 3.4 asystolic relating to the inability of the heart to empty itself 3.5 ataxia inability to co-ordinate voluntary movements 3.6 barotrauma damage to the ears caused by rapid ch

45、ange of pressure 3.7 bradycardia slowness of the heartbeat 3.8 bronchospasm sustained involuntary muscular contractions of the windpipe TR 62713 IEC:2013 7 3.9 cardiopulmonary relating to the heart and lungs 3.10 cardiovascular relating to the heart and vessels 3.11 cutaneous belonging to or relatin

46、g to the skin 3.12 electrization process of electrification, not necessarily resulting in death (electrocution) 3.13 erythemateous reddening of the skin 3.14 hypertension high blood pressure 3.15 hypotension low blood pressure 3.16 keraunoparalysis paralysis caused by thunderstorms 3.17 macular punc

47、ture puncturing of the eyes macula, or yellow spot, a small area at the centre of the retina at which vision is most distinct 3.18 nystagmus spasmodic involuntary lateral oscillatory movement of the eyes 3.19 otorrhea discharge from the ear 3.20 papillary like, or of the nature of, or having papilla

48、e small nipple like protuberances 3.21 paeresthesia paresthesia abnormal sensation in any part of the body 3.22 pathognomic indicative of a particular disease 8 TR 62713 IEC:2013 3.23 sequela any abnormal condition following or relating to a previous disease; the psychological after- effect of any t

49、rauma 3.24 tachycardia abnormal rapidity of the heartbeat 3.25 tympanic membrane membrane separating the middle ear form the outer ear 3.26 ventricular fibrillation uncontrolled rapid electric activity of a heart ventricle 4 General 4.1 Introductory remark Generally, the instantaneous power brought by lightning is very high. Indeed, this energy acts on an object for less than a few milliseconds (ms). Hig

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1