1、 IEC 60728-7-3 Edition 2.0 2009-10 INTERNATIONAL STANDARD Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) IEC 60728-7-3:2009(E) colour inside THIS PUBLICATION I
2、S COPYRIGHT PROTECTED Copyright 2009 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from eit
3、her IEC or IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC
4、 Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related techn
5、ologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue
6、 enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a m
7、onth all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages.
8、Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919
9、 02 11 Fax: +41 22 919 03 00 IEC 60728-7-3 Edition 2.0 2009-10 INTERNATIONAL STANDARD Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) INTERNATIONAL ELECTROTECHN
10、ICAL COMMISSION W ICS 33.040; 33.160 PRICE CODE ISBN 2-8318-1065-1 Registered trademark of the International Electrotechnical Commission colour inside 2 60728-7-3 IEC:2009(E) CONTENTS FOREWORD.5 INTRODUCTION.7 1 Scope.8 2 Normative references .9 3 Terms, definitions and abbreviations 9 3.1 Terms and
11、 definitions 9 3.2 Abbreviations 10 4 Reference architecture forward and return channel specifications 10 5 Power supply to transponder interface bus specification overview 11 5.1 General .11 5.2 Interface compliance .11 5.3 Implementation compliance .11 5.4 Revision control 12 6 Power supply to tra
12、nsponder interface bus Physical layer specification .12 6.1 Interface requirements 12 6.1.1 Connector type 12 6.1.2 Communications interface .12 6.1.3 Connector signals12 6.1.4 Transponder power12 6.1.5 Line balance13 6.1.6 Cable length13 6.1.7 Data encoding .13 6.1.8 Bit rate 13 6.1.9 Duplex.13 6.1
13、.10 Method of communications 13 6.1.11 Indicators 13 6.2 Interface diagram 14 7 Alternative power supply to transponder interface bus Physical layer specification .15 7.1 Introduction to alternative15 7.2 Interface requirements 15 7.2.1 Connector type 15 7.2.2 Communications interface .15 7.2.3 Conn
14、ector signals15 7.2.4 Transponder power15 7.2.5 Line balance16 7.2.6 Cable length16 7.2.7 Data encoding .16 7.2.8 Bit rate 16 7.2.9 Duplex.16 7.2.10 Method of communication16 7.2.11 Indicators 17 7.3 Interface diagram 17 8 Power supply to transponder interface bus Data link layer specification.18 8.
15、1 DLL packet structure .18 60728-7-3 IEC:2009(E) 3 8.1.1 General .18 8.1.2 Start 18 8.1.3 Destination Address 18 8.1.4 Source Address.19 8.1.5 Identification19 8.1.6 Datagram 19 8.1.7 End .19 8.1.8 Checksum .19 8.2 DLE sequence.19 8.3 Interface timing .20 8.3.1 Message synchronization and interactio
16、n 20 8.3.2 Transmission timing requirements .21 8.4 DLL datagrams22 8.4.1 Structure .22 8.4.2 Resolution versus accuracy.23 8.4.3 DLL datagram types 23 Annex A (informative) HMS specification documents37 Bibliography38 Figure 1 Reference architecture diagram .11 Figure 2 Sample PSTIB RS-485 interfac
17、e 14 Figure 3 Sample PSTIB RS-485 interface 17 Figure 4 DLL packet structure18 Figure 5 PSTIB data and timing diagram21 Figure 6 DLL datagram structure22 Figure 7 Battery string naming conventions33 Table 1 Transponder type classifications .8 Table 2 RJ-45 Connector pin assignment.12 Table 3 Sample
18、PSTIB RS-485 interface Reference signals14 Table 4 RJ-45 Connector pin assignment.15 Table 5 Sample PSTIB RS-485 interface Reference signals17 Table 6 Generic DLL packet structure18 Table 7 Reserved destination address ranges19 Table 8 PSTIB timing specifications.21 Table 9 Generic DLL datagram stru
19、cture22 Table 10 DLL datagrams24 Table 11 Command: Get_Configuration datagram24 Table 12 Response: Get_Configuration datagram 25 Table 13 Response: Get_Configuration datagram variable binding (general)25 Table 14 Response: Get_Configuration datagram variable binding (power supply).26 Table 15 Respon
20、se: Get_Configuration datagramavariable binding (generator) .29 Table 16 Command: Get_Power_Supply_Data datagram .30 Table 17 Response: Get_Power_Supply_Data datagram .30 Table 18 Response: Get_Power_Supply_Data datagram variable binding30 4 60728-7-3 IEC:2009(E) Table 19 Command: Power_Supply_Contr
21、ol datagram.33 Table 20 Command: Get_Generator_Data datagram33 Table 21 Response: Get_Generator_Data datagram 34 Table 22 Response: Get_Generator_Data Datagram variable binding34 Table 23 Command: Generator_Control datagram .35 Table 24 Response: Invalid_Request datagram .35 Table 25 Response: Reque
22、st_Processed datagram .36 Table A.1 HMS document family 37 60728-7-3 IEC:2009(E) 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interfa
23、ce bus (PSTIB) FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote interna- tional co-operation on all questions concerning stand
24、ardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Techni- cal Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their prepara
25、tion is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organiza- tions liaising with the IEC also participate in this preparation. IEC collaborates closely w
26、ith the International Or- ganization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant
27、subjects since each technical committee has representation from all inter- ested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the tec
28、hnical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinter- pretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum
29、extent possible in their national and regional publications. Any divergence be- tween any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies pr
30、ovide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC o
31、r its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and ex- p
32、enses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publica- tions. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) A
33、ttention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of pat- ent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60728-7-3 has been prepared by technical area 5: Cable networks fo
34、r television signals, sound signals and interactive services, of IEC technical committee 100: Audio, video and multimedia systems and equipment. This second edition cancels and replaces the first edition published in 2003 of which it consti- tutes a technical revision. This edition includes the foll
35、owing significant technical changes with respect to the previous edition: All changes from standard ANSI/SCTE 25-3 v1.0 to standard ANSI/SCTE 25-3 v1.1 (2005) have been taken into account in this second edition. Clause 7 is based on standard ANSI/SCTE 110 (2005). Addition of informative Annex A conc
36、erning hybrid management sub-layer. 6 60728-7-3 IEC:2009(E) The text of this standard is based on the following documents: CDV Report on voting 100/1464/CDV 100/1599/RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table
37、. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 60728 series, under the general title Cable networks for television signals, sound signals and interactive services, can be found on the IEC website. The committee has decided that t
38、he contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended
39、. A bilingual version of this publication may be issued at a later date. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this docume
40、nt using a colour printer. 60728-7-3 IEC:2009(E) 7 INTRODUCTION Standards of the IEC 60728 series deal with cable networks including equipment and associ- ated methods of measurement for headend reception, processing and distribution of television signals, sound signals and their associated data sig
41、nals and for processing, interfacing and transmitting all kinds of signals for interactive services using all applicable transmission me- dia. This includes CATV 1 -networks; MATV-networks and SMATV-networks; individual receiving networks; and all kinds of equipment, systems and installations instal
42、led in such networks. The extent of this standardization work is from the antennas and/or special signal source in- puts to the head-end or other interface points to the network up to the terminal input. The standardization of any user terminals (i.e. tuners, receivers, decoders, multimedia termi- n
43、als, etc.) as well as of any coaxial, balanced and optical cables and accessories thereof is excluded. The following differences exist in some countries: The Japanese de facto standard (NCTEA S-006) concerning requirements for the HFC out- side plant management, which was published in 1995, has alre
44、ady been available in Japan. The purpose of this standard is to support the design and implementation of interoperable management systems for HFC cable networks used in Japan. _ 1This word encompasses the HFC networks used nowadays to provide telecommunications services, voice, data, audio and video
45、 both broadcast and narrowcast. 8 60728-7-3 IEC:2009(E) CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) 1 Scope This part of IEC 60728 specifies requirements fo
46、r the Hybrid Fibre Coax (HFC) Outside Plant (OSP) Power Supplies (PS). This standard is part of a series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The purpose of the standards is to support the design and implementation of
47、 interoperable management systems for evolving HFC cable networks. The Power Supply to Transponder In- terface Bus (PSTIB) specification describes the physical (PHY) interface and related messag- ing and protocols implemented at the Data Link Layer (DLL), layers 1 and 2 respectively in the 7-layer I
48、SO-OSI reference model, that support communications between compliant trans- ponders and the managed OSP power supplies and other related power equipment to which they interface. This standard describes the PSTIB PHY and DLL layer requirements and protocols that shall be implemented to support relia
49、ble communications between all type 2 and type 3 compliant OSP transponders on the HFC plant and managed OSP power supplies and related hardware. Any exceptions to compliance with this standard will be specifically noted as necessary. Transponder type classifications referenced within the HMS series of standards are defined in Table 1. Table 1 Transponder type classifications Type Descripti