IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf

上传人:unhappyhay135 文档编号:1241975 上传时间:2019-08-25 格式:PDF 页数:18 大小:511KB
下载 相关 举报
IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf_第1页
第1页 / 共18页
IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf_第2页
第2页 / 共18页
IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf_第3页
第3页 / 共18页
IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf_第4页
第4页 / 共18页
IEC 62391-2-1-2006 Fixed electric double-layer capacitors for use in electronic equipment - Part 2-1 Blank detail specification - Electric double-layer capacito.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、 INTERNATIONAL STANDARD IEC 62391-2-1First edition 2006-04Fixed electric double-layer capacitors for use in electronic equipment Part 2-1: Blank detail specification Electric double-layer capacitors for power application Assessment level EZ Reference number IEC 62391-2-1:2006(E) Publication numberin

2、g As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, re

3、spectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content re

4、flects current technology. Information relating to this publication, including its validity, is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by the te

5、chnical committee which has prepared this publication, as well as the list of publications issued, is also available from the following: IEC Web Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to search by a variety of crit

6、eria including text searches, technical committees and date of publication. On-line information is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/online_news/ just

7、pub) is also available by email. Please contact the Customer Service Centre (see below) for further information. Customer Service Centre If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 22 919

8、02 11 Fax: +41 22 919 03 00 INTERNATIONAL STANDARD IEC 62391-2-1First edition 2006-04Fixed electric double-layer capacitors for use in electronic equipment Part 2-1: Blank detail specification Electric double-layer capacitors for power application Assessment level EZ IEC 2006 Copyright - all rights

9、reserved No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20

10、 Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch L For price, see current catalogue PRICE CODE Commission Electrotechnique Internationale International Electrotechnical Commission 2 62391-2-1 IEC:2006(E) INTERNATIONAL ELECTROTECHNICAL COMMISSIO

11、N _ FIXED ELECTRIC DOUBLE-LAYER CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 2-1: Blank detail specification Electric double-layer capacitors for power application Assessment level EZ FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization c

12、omprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International S

13、tandards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this p

14、reparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two or

15、ganizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the fo

16、rm of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpret

17、ation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or r

18、egional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this

19、publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indir

20、ect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the

21、 correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 62391-2-1 has been pre

22、pared by IEC technical committee 40: Capacitors and resistors for electronic equipment. The text of this standard is based on the following documents: FDIS Report on voting 40/1642/FDIS 40/1714/RVD Full information on the voting for the approval of this standard can be found in the report on voting

23、indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. 62391-2-1 IEC:2006(E) 3 IEC 62391 consists of the following parts, under the general title Fixed electric double-layer capacitors for use in electronic equipment: Part 1: Generic specif

24、ication Part 2: Sectional specification Electric double-layer capacitors for power application The sectional specification mentioned above does have a blank detail specification being a supplementary document, containing requirements for style, layout and minimum content of detail specifications. Th

25、e committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; replaced by

26、 a revised edition, or amended. A bilingual version of this publication may be issued at a later date. 4 62391-2-1 IEC:2006(E) FIXED ELECTRIC DOUBLE-LAYER CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 2-1: Blank detail specification Electric double-layer capacitors for power application Assessment

27、 level EZ INTRODUCTION Blank detail specification A blank detail specification is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be c

28、onsidered as being in accordance with IEC specifications nor shall they so be described. In the preparation of detail specifications, the content of 1.4 of the sectional specification shall be taken into account. The numbers between square brackets on the first page of the detail specification corre

29、spond to the following information, which shall be inserted in the position indicated. Identification of the detail specification 1 The “International Electrotechnical Commission” or the National Standards Organization under whose authority the detail specification is drafted. 2 The IEC or National

30、Standards number of the detail specification, date of issue and any further information required by the national system. 3 The number and issue number of the IEC or national generic specification. 4 The IEC number of the blank detail specification. Identification of the capacitor 5 A short descripti

31、on of the type of capacitor. 6 Information on typical construction (when applicable). NOTE When the capacitor is not designed for use in printed circuit-board applications, this is clearly stated in the detail specification in this position. 7 Outline drawing with main dimensions which are of import

32、ance for interchangeability and/or reference to the national or international documents for outlines. Alternatively, this drawing may be given in an annex to the detail specification. 8 Application or group of applications covered and/or assessment level. 9 Reference data on the most important prope

33、rties, to allow comparison between the various capacitor types. 62391-2-1 IEC:2006(E) 5 1 IEC 62391-2-1-XXX 2 QC XXXXXXXXXXX IEC 62391-2-1 4 QC XXXXXX ELECTRONIC COMPONENTS OF ASSESSED QUALITY IN ACCORDANCE WITH: 3 ELECTRIC DOUBLE-LAYER CAPACITORS FOR POWER APPLICATION 5 6 Outline drawing: (see Tabl

34、e 1) (angle projection) 7 Assessment level(s): EZ 8 NOTE For 1 to 9: see previous page. Information on the availability of components qualified to this detail specification is given in IEC QC 001005. 9 6 62391-2-1 IEC:2006(E) 1 General data 1.1 Recommended method(s) of mounting (to be inserted) See

35、1.4.2 of IEC 62391-2. 1.2 Dimensions Dimensions are given in Table 1. Table 1 Case size reference and dimensions Dimensions mm Case size reference W H d NOTE 1 When there is no case size reference, Table 1 may be omitted and the dimensions should be given in Table 2a, which then becomes Table 1. NOT

36、E 2 The dimensions should be given as maximum dimensions or as nominal dimensions with a tolerance. 1.3 Ratings and characteristics Rated capacitance range (see Table 2a). Tolerance on rated capacitance. Rated voltage (see Table 2a). Climatic category. Rated temperature. Internal resistance (see Tab

37、le 2b). Leakage current (if applicable). Table 2a Values of capacitance and of voltage related to case sizes Rated voltage Case sizes Case sizes Case sizes Case sizes Rated capacitance F Table 2b Values of internal resistance and leakage current U R V C R F Internal resistance at C Leakage current A

38、 (if applicable) 62391-2-1 IEC:2006(E) 7 1.4 Normative references IEC 60410, Sampling plans and procedures for inspection by attributes IEC 62391-1, Fixed electric double-layer capacitors for use in electronic equipment Part 1: Generic specification IEC 62391-2, Fixed electric double-layer capacitor

39、s for use in electronic equipment Part 2: Sectional specification Electric double-layer capacitors for power application IEC QC 001005, Rules of procedure Part 5: Hazardous substances process management requirements 1.5 Marking The marking of the capacitor and the package shall be in accordance with

40、 the requirements of 1.6 of IEC 62391-2. NOTE The details of the marking of the component and package should be given in full in the detail specification. 1.6 Ordering information Orders for capacitors covered by this specification shall contain, in clear or in coded form, the following minimum info

41、rmation. a) Rated capacitance. b) Tolerance on rated capacitance. c) Rated d.c. voltage. d) Number and issue reference of the detail specification and style reference. e) Packaging instructions. 1.7 Certified records of released lots Required/not required. 1.8 Additional information (not for inspect

42、ion purposes) 1.9 Additional or increased severities or requirements to those specified in the generic and/or sectional specification NOTE Additions or increased requirements should be specified only when essential. Table 3 Other characteristics This table is to be used for defining characteristics

43、which are additional to or more severe than those given in the sectional specification. 2 Inspection requirements 2.1 Procedures 2.1.1 For qualification approval, the procedures shall be in accordance with 3.4 of IEC 62391-2. 8 62391-2-1 IEC:2006(E) 2.1.2 For quality conformance inspection, the test

44、 schedule (Table 4) includes sampling, periodicity, severities and requirements. The formation of inspection lots is covered by 3.5.1 of IEC 62391-2. Table 4 Test schedule for quality conformance inspection Number of specimens and number of non- conforming items bSubclause number and test aD or ND b

45、Conditions of test aIL n c Performance requirements aGroup A inspection (lot-by-lot) Subgroup A0 4.4.2 Capacitance ND According to Class 3 100 % c Within specified tolerance 4.4.3 Internal resistance DC resistance: according to Class 3 fAs in Table 2b 4.4.1 Leakage current (if applicable) Protective

46、 resistor As in Table 2b Subgroup A1 ND S-3 d0 4.3 Visual examination As in 4.3.2 Legible marking and as specified in the detail specification Subgroup A2 ND S-3 d0 4.3 Dimension (detail) eAs specified in Table 1 of this specification Group B inspection (lot-by-lot) Subgroup B1 D S-3 d0 4.7 Solderab

47、ility gTest method: Solder bath method (Method 1) 4.7.1 Final measurement Visual examination 75 %, or more, of terminals shall be covered with new solder Subgroup B2 4.13 Characteristics at high and low temperature ND Step 1: 20 C Capacitance Internal resistance Step 2: 25 C Capacitance S-3 d0 C/C 3

48、0 % of value measured in Step 1 Internal resistance 4 times the limit specified in 4.4.3 62391-2-1 IEC:2006(E) 9 Group C inspection (Periodic) Subgroup C1A D 12 8 0 4.3 Dimension (detail) h As specified in Table 1 of this specification 4.5 Robustness of terminations Test method: Test U a1(tensile st

49、rength) Test U b(bending strength) 4.5.1 Initial measurement Capacitance 4.5.2 Final measurement Visual examination Capacitance No visible damage Legible marking C/C 10 % of value measured in 4.5.1 4.6 Resistance to soldering heat gMethod 1a of Test Tb Recovery: 4.6.1 Initial measurement Capacitance 4.6.3 Final measurement Visual examination Capacit

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1