ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf

上传人:sofeeling205 文档编号:1243432 上传时间:2019-08-27 格式:PDF 页数:5 大小:113.59KB
下载 相关 举报
ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf_第1页
第1页 / 共5页
ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf_第2页
第2页 / 共5页
ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf_第3页
第3页 / 共5页
ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf_第4页
第4页 / 共5页
ASTM B830-2018 Standard Specification for Uniform Test Methods and Frequency.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: B830 11B830 18Standard Specification forUniform Test Methods and Frequency1This standard is issued under the fixed designation B830; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i

2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers a standard basis for uniform testing and frequency to determine physical and electrical compliancefor aluminum and co

3、pper drawing stock, and aluminum and copper conductors.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.2.1 ExceptionResistivity i

4、s measured in SI units.1.3 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization T

5、echnical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 The following documents, of the issue in effect on date of material purchase date issued, form a part of this specificationto the extent referenced herein.2.2 ASTM Standards:2E29 Practice for Using Significant Digits in Test Data

6、to Determine Conformance with Specifications2.3 National Bureau of Standards:3NBS Handbook 100 Handbook 100, Copper Copper Wire Tables2.4 Canadian Standards Association:4CAN/CSA-ISO 9001-08 Quality Management Systems RequirementsCAN/CSA Z299.3-85 (R2006) Quality Assurance Program - Category 31 This

7、specification is under the jurisdiction of ASTM Committee B01 on Electrical Conductors and is the direct responsibility of Subcommittee B01.02 on Methods ofTest and Sampling Procedure.Current edition approved Oct. 1, 2011June 15, 2018. Published November 2011January 2019. Originally approved in 1993

8、. Last previous edition approved in 20032011as B830 97B830 11. (2003). DOI: 10.1520/B0830-11.10.1520/B0830-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the sta

9、ndards Document Summary page on the ASTM website.3 Available from National Technical Information Service (NTIS), 5301 Shawnee Rd., Alexandria, VA 22312, http:/www.ntis.gov.5 This ANSI standard is an identical adoption of ISO 9001:2015 and the text does not differ in any way from ISO 9001:2015.This d

10、ocument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions

11、as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.4 ANSI Standards:4ANSI/ISO/ASQ 9001-2015 3534-1-2006

12、 Statistics-Vocabulary and Symbols Part 1-General Statistical Terms and Terms UsedIn Probability Quality Management SystemsRequirementsANSI/ISO/ASQ 3534-2-2006 Statistics-Vocabulary and Symbols Part 2-Applied StatisticsANSI/ISO/ASQ Q9001-2008 Quality Management Systems - RequirementsANSI/ISO/ASQ Q90

13、04-2009 Q9004-1-2009 Managing for the Sustained Success of an Organization A OrganizationAQuality Management Approach5ANSI/ASQC C1-1996 Specification of General Requirements for a Quality ProgramANSI/ASQC S1-1996S1-2012 An Attribute Skip-Lot Sampling ProgramANSI/ASQ Z1.4-2003 (R2013) Z1.4-2008 Sampl

14、ing Procedures and Tables for Inspection by Attributes3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 acceptable quality level (AQL)the maximum percent nonconforming (or the maximum number of nonconformities perhundred units) that, for purposes of sampling inspection, can be c

15、onsidered as a process average.3.1.2 average outgoing quality (AOQ)the average quality of outgoing product, including all accepted lots or batches, plus alllots or batches not accepted after such lots or batches have been effectively 100 % inspected and all nonconforming units replacedby conforming

16、units.3.1.3 CPKProcess Performance Index.Discussion:Capability in Relation to Spec Mean:USL = 5.0LSL = 1.0MEAN = 2.0Standard deviation () = 0.5CPK tells the capability of a process based upon the worst case view of the data.The equation is:CPK = the lesser of:4 Available from Canadian Standards Asso

17、ciation (CSA), 5060 Spectrum Way, Mississauga, ON L4W 5N6, Canada, http:/www.csa.ca.4 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.B830 182USL2MEAN!3 orMEAN2LSL!3 (1)For example:CPK55.022.0!1.5 or 2.021.0!1.5 (2)52.0 o

18、r 0.6750.67A negative value for CPK indicates that the mean is outside the specification limits. A CPK of zero indicates that the meanis equal to one of the specification limits. A CPK between 0 and 1.0 means that part of the 6 sigma limits falls outside thespecification limits. A CPK of 1.0 means t

19、hat one end of the 6 sigma limits falls on a specification limit. A CPK larger than1.0 means that the 6 sigma limits fall completely within the specification limits. See Explanatory Note 1 for an example inter-pretation of CPK values and actions to follow.Capability indices are useful tools in the a

20、nalysis of capability data. The most useful index is CPK, since it formulates capa-bility in a manner that relates to shifts in the mean of the distribution away from the midpoint.3.1.4 lota group of production units of one type and size of wire, which were produced during the same time period under

21、similar production conditions, and are presented for acceptance at the same time. The mass will be defined in theASTM documentfor the specific product to be tested.3.1.5 process averagethe average percent nonconforming or average number of nonconformities per hundred units(whichever is applicable) o

22、f product submitted by the supplier for original inspection. Original inspection is the first inspection ofa particular quantity of product as distinguished from the inspection of product that has been resubmitted after prior rejection.When double or multiple sampling is used, only the first sample

23、results shall be included in the process average calculation.3.1.6 production unita coil, reel, spool, or other package of drawing stock/wire that represents a single usable length.3.1.7 samplethe production unit or units from which a test specimen or specimens have been removed and which areconside

24、red to have properties representative of the lot.3.1.8 specimena length of drawing stock/wire removed for test purposes.4. Methods for Ensuring Product Compliance4.1 Acceptance Sampling:4.1.1 When acceptance sampling is used, statistical sampling of each lot shall be presented for inspection in acco

25、rdance withANSI/ASQ Z1.4-2008. Z1.4-2003 (R2013). Sampling of each lot shall be presented for normal inspection in accordance with thesampling system described by ANSI/ASQ Z1.4-2008.Z1.4-2003 (R2013).4.1.2 Diameter and tensile shall be tested using General Inspection Level 1 with an AQL (acceptable

26、quality level) of 4.0 %.(See Table 1.)4.1.3 Resistivity shall be tested using Special Inspection Level S-4 with an AQL of 4.0 %. (See Table 2.)4.1.4 All other material properties shall be tested per the specific level and AQL in ANSI/ASQ Z1.4-2008 Z1.4-2003 (R2013)as required in the ASTM specificati

27、on for the specific product.4.1.5 Test records shall meet the requirements of ANSI/ASQ Q9001-2008,9001-2015, Section 4.16.7.5.1.4.2 Conformance Criteria:4.2.1 Failure of a specimen to conform to the applicable requirements of ASTM shall constitute failure of the production unitfrom which the specime

28、n was taken. Sampling of each lot shall be switched according to the rules described in ANSI/ASQZ1.4-2008. Z1.4-2003 (R2013). (See Fig. 1.)TABLE 1 Sampling for Diameter and Tensile Properties Except JointsNOTE 1This sampling plan was taken fromANSI/ASQ Z1.4-2008. Z1.4-2003 (R2013). General Inspectio

29、n Level I, normal sampling was used, withan AQL (Acceptance Quality Level) of 4.0 %.Number of Units in Lot Sample Sample Size CumulativeSample Size AcceptanceNumber RejectNumber1 to 3 firstA all all 0 14 to 90 firstA 3 3 0 191 to 280 first 8 8 0 2second 8 16 1 2281 to 500 first 13 13 0 3second 13 26

30、 3 4501 to 1200 first 20 20 1 4second 20 40 4 5A Single sampling only.B830 1834.2.2 Any lot of drawing stock/wire that has been sampled in accordance with 4.1.2, 4.1.3, or 4.1.4, and from which the numberof specimens failing to comply with the requirements does not equal or exceed the appropriate re

31、ject number of the sampling Table1 used, shall be considered as complying with the requirements of ASTM.4.2.3 Rejected lots may be screened to remove nonconforming production units by testing one specimen from each productionunit in the lot for the failing characteristic.4.2.4 Sample SizeThe sample

32、size shall be the number of production units selected.4.3 Provisions for Skip-lot Inspection:4.3.1 When reduced inspection is in effect (see 4.2), skip-lot inspection shall be allowed when the preceding ten lots have beenaccepted in accordance withANSI/ASQ Z1.4-2008. Z1.4-2003 (R2013). Skip-lot test

33、ing shall be in accordance withANSI/ASQCS1-1996.S1-2012.4.3.2 When skip-lot inspection is in effect, normal inspection (see 4.1) shall be instituted if any lot is found unacceptable.4.4 When skip-lot inspection (see 4.3) is in effect, and the preceding ten inspected lots have been accepted, audit in

34、spection shallbe instituted by the manufacturer in accordance with the following statistical process control (SPC) program requirements.4.4.1 CPK 1.0 for 10 lots in control with less than 2 out-of-control indications.5. Statistical Process Control5.1 When statistical process control (SPC) is used, t

35、he manufacturer shall comply with CSA Standard Z299.3, Section 3.5,ANSI/ASQ Q9004-1-2009,ANSI/ASQ Q9004-2009, Sections 10 and 20.5.1.1 Basic inspection and testing system requirements shall conform to ANSI/ASQ Q9001-2008,9001-2015, Section 4.10.8.5.5.2 Statistical Techniques:5.2.1 Identify and class

36、ify product, process, and service characteristics for which statistical techniques will be used as basis forthe assurance and control of quality and acceptance or rejection of lots.5.2.2 When statistical techniques are used, the property being evaluated shall comply with the requirements of the appl

37、icableASTM standard. The process performance index (CPK) shall not be less than 1.0. A process performance index (CPK) of 1.3should be considered a goal.TABLE 2 Sampling for Resistivity PropertiesNOTE 1This sampling plan was taken fromANSI/ASQ Z1.4-2008. Z1.4-2003 (R2013). Special Inspection Level S

38、-4, normal sampling was used, withan AQL (Acceptance Quality Level) of 4.0 %.Number of Units in Lot Sample Sample Size CumulativeSample Size AcceptanceNumber RejectNumber1 to 3 firstA all all 0 14 to 90 firstA 3 3 0 191 to 500 first 8 8 0 2second 8 16 1 2501 to 1200 first 13 13 0 3second 13 26 3 4A

39、Single sampling only.FIG. 1 Switching Rules for ANSI/ASQ Z1.4-2008 Z1.4-2003 (R2013) SystemB830 1845.2.3 Other physical or electrical properties shall have statistical techniques applied at the suppliers option or if specified inthe applicable ASTM standard.5.2.4 Select appropriate statistical techn

40、iques and confidence levels for process control and product acceptance and indicate thebasis for selection. Control charts and statistical data shall follow ASTM Manual 76 for form, style, and data presentation.5.2.5 Apply the statistical techniques selected, review them for adequacy, and monitor th

41、eir application to ensure the specifiedASTM requirements are met.5.2.6 Include or reference the selected statistical techniques used for product or service acceptance or special process monitoringspecified in the inspection and test plan(s), ANSI/ASQ Q9001-2008,9001-2015, Sections 4.104.4 and 4.20.6

42、.2.5.3 Quality Audits:5.3.1 Control charts following the form and style ofASTM Manual 76 shall be provided, if requested, to the customer with eachorder that is representative of the processes used in the manufacture of the product.5.3.2 Records shall be kept in accordance with ANSI/ASQ Q9001-2008,9

43、001-2015, Section 4.16.7.5.1.6. Keywords6.1 acceptable quality level (AQL); average outgoing quality (AOQ); control chart; lot; lower specification limit (LSL); processaverage; process control ratio (CPK); skip-lot inspection; statistical process control (SPC); upper specification limit (USL)EXPLANA

44、TORY NOTESNOTE 1The following is an example of how one might interpret the CPK results and determine the frequency of monitoring a specific test:Between 0 and 1.0 CPK = Inspection required as process unstable, failures will occur.Between 1.0 and 1.33 CPK = Monthly Audit required to prevent process d

45、riftBetween 1.33 and 1.5 CPK = Process Capability Audit at least every 6 monthsMore than 1.5 = Capability Audit annually.Between 0 and 1.0 CPK = Inspection required as process unstable, failures will occurBetween 1.0 and 1.33 CPK = Monthly Audit required to prevent process driftBetween 1.33 and 1.5

46、CPK = Process Capability Audit at least every 6 monthsMore than 1.5 = Capability Audit annuallyASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determina

47、tion of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or with

48、drawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your

49、 comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the