IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf

上传人:hopesteam270 文档编号:1248044 上传时间:2019-09-02 格式:PDF 页数:27 大小:381.05KB
下载 相关 举报
IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf_第1页
第1页 / 共27页
IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf_第2页
第2页 / 共27页
IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf_第3页
第3页 / 共27页
IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf_第4页
第4页 / 共27页
IEEE 1140-1994 en Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz《5Hz到400kHz显示器.pdf_第5页
第5页 / 共27页
点击查看更多>>
资源描述

1、Copyright 1998 IEEE All Rights Reserved 1IEEE Std 1140-1994 (R2006)IEEE Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHzSponsorElectromagnetic Compatibility Society Standards Committeeof theIEEE Electromagnetic Compatibi

2、lity SocietyApproved March 17, 1994Reaffirmed September 14, 2006IEEE Standards BoardAbstract: Procedures for the measurement of electric and magnetic fields in close proximity to video displayterminals (VDTs) in the frequency range of 5 Hz to 400 kHz are provided. Existing international measurementt

3、echnologies and practices are adapted to achieve a consistent and harmonious VDT measurement standard fortesting in a laboratory controlled environment.Keywords: electric field, magnetic field, video display terminal (VDT)The Institute of Electrical and Electronics Engineers, Inc.345 East 47th Stree

4、t, New York, NY 10017-2394, USACopyright 1994 by the Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 1994. Printed in the United States of AmericaISBN 1-55937-423-3No part of this publication may be reproduced in any form, in an electronic retrieval system or o

5、therwise, without theprior written permission of the publisher.IEEE Standardsdocuments are developed within the Technical Committees of theIEEE Societies and the Standards Coordinating Committees of the IEEE StandardsBoard. Members of the committees serve voluntarily and without compensation.They ar

6、e not necessarily members of the Institute. The standards developed withinIEEE represent a consensus of the broad expertise on the subject within the Instituteas well as those activities outside of IEEE that have expressed an interest in partici-pating in the development of the standard.Use of an IE

7、EE Standard is wholly voluntary. The existence of an IEEE Standarddoes not imply that there are no other ways to produce, test, measure, purchase, mar-ket, or provide other goods and services related to the scope of the IEEE Standard.Furthermore, the viewpoint expressed at the time a standard is app

8、roved and issued issubject to change brought about through developments in the state of the art and com-ments received from users of the standard. Every IEEE Standard is subjected toreview at least every ve years for revision or reafrmation. When a document ismore than ve years old and has not been

9、reafrmed, it is reasonable to conclude thatits contents, although still of some value, do not wholly reect the present state of theart. Users are cautioned to check to determine that they have the latest edition of anyIEEE Standard.Comments for revision of IEEE Standards are welcome from any interes

10、ted party,regardless of membership afliation with IEEE. Suggestions for changes in docu-ments should be in the form of a proposed change of text, together with appropriatesupporting comments.Interpretations: Occasionally questions may arise regarding the meaning of portionsof standards as they relat

11、e to specic applications. When the need for interpretationsis brought to the attention of IEEE, the Institute will initiate action to prepare appro-priate responses. Since IEEE Standards represent a consensus of all concerned inter-ests, it is important to ensure that any interpretation has also rec

12、eived the concurrenceof a balance of interests. For this reason IEEE and the members of its technical com-mittees are not able to provide an instant response to interpretation requests except inthose cases where the matter has previously received formal consideration. Comments on standards and reque

13、sts for interpretations should be addressed to:Secretary, IEEE Standards Board445 Hoes LaneP.O. Box 1331Piscataway, NJ 08855-1331USAIEEE standards documents may involve the use of patented technology. Theirapproval by the Institute of Electrical and Electronics Engineers does not mean thatusing such

14、 technology for the purpose of conforming to such standards is authorizedby the patent owner. It is the obligation of the user of such technology to obtain allnecessary permissions.iiiAt the time this standard was completed, the Working Group had the following membership:D. Moongilan,ChairD. Traver,

15、Vice ChairS. Berger A. Light S. A. RobertsJ. Chubb M. Misakian R. A. SuttonR. Justice D. Moongilan D. WittersR. C. PetersonThe following persons were on the balloting committee:IntroductionThis introduction is not part of IEEE Std 1140-1994, IEEE Standard Procedures for the Measurement of Electric a

16、ndMagnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz.The purpose of this standard is to establish uniform procedures for the measurement of electric and magneticfields from video display terminals (VDTs). The measurement practices in this standard follow the princi-ples and pro

17、cedures of MPR (National Board for Measurement and Testing) published in Sweden. The num-ber of test points required, calibration levels, instrumentation and calibration procedures used, grounded andungrounded system test methods, and calculation of measurement uncertainty are different from MPR. Th

18、emeasurement procedures outlined in this standard are for testing in a laboratory-controlled environment. Themeasurement distances indicated in this document are based on approximate human operator and VDT inter-action distance. The electric field measurements attempt to approximate the field that i

19、s perturbed by humanoperator interaction. Due to insufficient information defining safe or unsafe electric or magnetic field levelsfor human operators, this document does not assume any human factors other than test distance.This standard was revised 12 times to incorporate the comments of balloting

20、 members.The first working draft was completed in February 1991 by an ad hoc group with the following membership:C. AbernathyR. AshleyD. BaronH. BassenS. BergerW. BolvinE. BronaughF. BuckleyM. BurtonJ. ButlerC. CampD. CapplesH. DennyR. ElmserW. FloodD. GeorgeB. HanrahanD. N. HeirmanA. HoolihanB. Hun

21、terR. MacyS. MillendorfM. MisakianD. MoongilanS. NilssonT. NilssonJ. OsepchikJ. ParkerR. C. PetersonB. RhodesR. SatoR. ShowersD. StaggsR. TellD. TraverA. WilsonD. WittersS. A. RobertsJ. ChubbD. GeorgeK. GullicksonD. HanttulaL. HillJ. HowardA. LightD. MoongilanS. RobertsonJ. TinsmanJ. YenickPaul Zahr

22、aD. Moongilan,ChairivWhen the IEEE Standards Board approved this standard on March 17, 1994, it had the followingmembership:Wallace S. Read,ChairDonald C. Loughry,Vice ChairAndrew G. Salem,SecretaryGilles A. Baril Donald N. Heirman Joseph L. Koepnger*Bruce B. Barrow Richard J. Holleman D. N. Jim Log

23、othetisJos A. Berrios de la Paz Jim Isaak L. Bruce McClungClyde R. Camp Ben C. Johnson Marco W. MigliaroJames Costantino Sonny Kasturi Mary Lou PadgettStephen L. Diamond Lorraine C. Kevra Arthur K. ReillyDonald C. Fleckenstein E. G. Al Kiener Ronald H. ReimerJay Forster* Ivor N. Knight Gary S. Robin

24、sonRamiro Garcia Leonard L. Tripp*Member EmeritusAlso included are the following nonvoting IEEE Standards Board liaisons:Satish K. AggarwalJames BeallRichard B. EngelmanDavid E. SoffrinStanley I. WarshawStephen J. HuffmanIEEE Standards Project EditorvContentsCLAUSE PAGE1. Scope 12. Definitions 13. G

25、eneral conditions . 23.1 General. 23.2 Background electric field levels. 33.3 Background magnetic field (magnetic flux density) 34. Electric field test equipment 44.1 Electric field measuring probe. 44.2 Probe filters and signal processing 54.3 Calibration 55. Electric field strength measurement pro

26、cedure 65.1 VDT test setup . 65.2 Measurement procedure. 65.3 Measurement uncertainty. 76. Magnetic field test equipment 96.1 Magnetic field measuring probe 96.2 Probe filters and signal processing 106.3 Calibration 107. Magnetic flux density measurement procedure . 117.1 VDT test setup . 117.2 Meas

27、urement procedure. 117.3 Measurement uncertainty. 138. Bibliography 15viANNEXESA (normative) Electric eld measuring probeprinciple of operation 16B (normative) VDT characterizationtypical data recording format 19C (normative) Measurement uncertaintytypical data recording format . 20D (normative) Mea

28、surement instrumentation used. 211IEEE Standard Procedures for the Measurement of Electric and Magnetic Fields From Video Display Terminals (VDTs) From 5 Hz to 400 kHz1. ScopeThis standard provides procedures for the measurement of electric and magnetic elds in close proximity tovideo display termin

29、als (VDTs) in the frequency range of 5 Hz to 400 kHz. This standard adapts existinginternational measurement technologies B71and practices to achieve a consistent and harmonious VDTmeasurement standard for testing in a laboratory controlled environment. Such measurements are needed forinvestigative

30、studies that rely on the knowledge of electric and magnetic eld levels near electronicequipment.The requirements of the controlled laboratory test environment in which the characteristics specied in thisstandard are to be tested are difcult to establish at a users installation. Therefore, it is reco

31、gnized that theresults obtained in the laboratory may be difcult to reproduce in the on-site environment.This standard does not provide measurements at specic frequencies, but does provide one measurement foreach of two frequency bands: 5 Hz to 2 kHz and 2 kHz to 400 kHz.2. Denitions2.1 band I:The f

32、requency band 5 Hz to 2 kHz.2.2 band II:The frequency band 2 kHz to 400 kHz.1The numbers in brackets preceded by the letter B correspond to those of the bibliography in clause 8.IEEEStd 1140-1994 IEEE STANDARD PROCEDURES FOR THE MEASUREMENT OF ELECTRIC AND MAGNETIC22.3 background elds:Any electric o

33、r magnetic eld that does not originate from the VDT under test.2.4 calibration:The process of determining the numerical relationship, within an overall stated uncertainty,between the observed output of a measurement system and the value, based on standard sources, of the phys-ical quality being meas

34、ured. (In terms of this standard, the physical quality being measured is electric andmagnetic elds.)2.5 center-center point:A point on a VDT screen cathode ray tube (CRT) face panel that is both the hori-zontal and vertical mid-point. The center-center point is represented by the bisector of the hor

35、izontal andvertical center lines on the VDT screen.2.6 Class I equipment:Equipment in which protection against electric shock is achieved by: a) using basicinsulation, and b) providing a means of connecting the conductive parts, which are otherwise capable of assum-ing hazardous voltages if the basi

36、c insulation fails, to the protective ground conductor in the building wire.2.7 Class II equipment:Equipment in which protection against electric shock does not rely on basic insula-tion only, but also on the provision of additional safety precautions, such as double insulation or reinforcedinsulati

37、on. There is no provision for protective grounding or reliance upon installation conditions.2.8 eld measuring instrument:A device used to sense and read out the electric or magnetic eld intensi-ties surrounding a VDT under test. (For this standard, this instrumentation consists of three parts: probe

38、;readout detector, where the signal from the probe is processed and the data displayed; and any leads betweenthe probe and readout detector.)2.9 measurement uncertainty:The limits of error for a measured value, between which the true value willlie with the condence stated. (For this standard, measur

39、ement uncertainty is associated with measuring theabsolute value of the electric and magnetic elds.)2.10 tangential plane:The plane that is tangential to the surface of the VDT screen at the center-centerpoint.2.11 video display terminal (VDT):A device for the presentation of information by controll

40、ed excitation ofa CRT screen for visual observation designed for interactive use by an operator. For the purposes of thisstandard, the keyboard will not be included as part of VDT and is removed from the test area. This standardexcludes liquid crystal display (LCD) terminals.3. General conditions3.1

41、 General3.1.1 Location of VDT under test and measuring probeThe VDT under test, the measuring eld sensor (probe), and the signal processor/display (readout device ordetector) shall be positioned at least 1 m from all metallic structures and objects.The VDT under test shall be connected to the mains

42、supply with the power cord/cable supplied by the man-ufacturer as part of the equipment. The power cord/cable shall be positioned as follows: Horizontally for0.1 m from the test object, and then vertically down for at least 1 m.The power cord of the VDT under test shall be connected to the phase and

43、 neutral conductors of the mainspower network. If the power plug permits an interchange of the phase and neutral conductors, measurementsshall be taken with the connection that gives the highest Band I reading. If the VDT under test is designed toIEEEFIELDS FROM VIDEO DISPLAY TERMINALS (VDTs) FROM 5

44、 Hz TO 400 kHz Std 1140-19943be grounded, then the ground connection of the power cord shall be connected to ground. If the power cordof the VDT under test has a grounded neutral, then the neutral shall be connected to the ground.Additional units that are not part of the testsuch as the central proc

45、essing unit (CPU), video test patternsignal generators, and connecting cables necessary for the operation of the VDTshall be positioned sotheir elds do not exceed the required ambient levels (see 3.2 and 3.3). It is acceptable to add shielding andcables to these additional units as a long as a clear

46、ance of 1 m is maintained from the closest metallic part ofVDT under test or the measuring probe.The cables between the measuring probe and the readout (detector) shall be positioned so that they do notinuence the measured electric eld values. The cables will not affect the magnetic eld measurements

47、. 3.1.2 Power line voltageThe power line voltage of the VDT under test shall be within 3% of its nominal value, as stated on the man-ufacturers name plate. The nominal value of the power line voltage shall be specied in the test report andthe actual measured value shall be recorded. If a voltage ran

48、ge is specied, the test shall be performed at thecenter of the specied range. For this latter case, the power line voltage and the range shall be recorded in thetest report.3.2 Background electric eld levelsBackground electric eld levels in the test area, including power line transmitted disturbance

49、s and internallygenerated noise in the measuring system, shall not together exceed 2 V/m in Band I and 0.2 V/m in Band II.The background electric eld levels shall be measured with the VDT in place prior to beginning the VDTelectric eld measurements. All signal, power, and peripheral equipment cables required for operation shallbe on and terminated at the VDT. The VDT power cable shall be de-energized (otherwise the power cablewill radiate an electric eld) when making background measurements. If grounding and shielding of periph-eral

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1