1、IEEE Std 1584-2002_InterpretationIEEE Standards Interpretation for IEEE Std 1584 -2002IEEE Guide for Performing Arc-Flash Hazard Calculations Copyright 2008 by the Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue New York, New York 10016-5997 USA All Rights Reserved. This is an

2、interpretation of IEEE Std 1584-2002. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download and print one copy of this document

3、. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standard Department for the appropriate license. Use of the information contained in this document is at your own risk.IEEE Standards Department Copyrights

4、 and Permissions 445 Hoes Lane Piscataway, New Jersey 08855-1331, USADecember 2008Interpretation #1Is there an accepted practice or method in which incident energies can be lowered, therefore lowering the PPE category? http:/standards.ieee.org/reading/ieee/interp/1584-2002.html (1 of 4) 2009/01/06 9

5、:09:11 PMIEEE Std 1584-2002_InterpretationInterpretation Response #1The answer is IEEE Std 1584-2002 does not address practices or methods of lowering the incident energy because it would be outside the scope of this edition. However, the question is of great interest to users of the Guide and it wi

6、ll be addressed in the next edition. In the meantime, information on the subject is available from IEEE papers presented at the 2002 and 2003 PCIC Conferences. The papers are available in the PCIC record. The next opportunities to learn how people are solving this problem will be at the 2004 IAS Ele

7、ctrical Safety Workshop and at the 2004 IAS PCIC Conference. There are, in fact, many ways to reduce incident energy. Interpretation #2An interpretation of IEEE Std 1584-2002 “Guide for Performing Arc-Flash Hazard Calculations“ is requested. In 5.1, 7.5, and 9.1 the criteria for the model for incide

8、nt energy calculations includes “Bolted fault current in the range of 700A-106,000A.“ What is the significance of “700A,“ the lower limit of the range. Is there a particular reason why it is 700A, and not 600A, 500A, 400A, etc.?Several arc flash studies are currently being conducted in which the bol

9、ted fault current for a few busses is lower than 700A. The software tools used to conduct the studies make it clear that this fault level is outside of the range of IEEE 1584 and leave it at that. How to treat these situations is uncertain. Can it be concluded, for example, that incident energy is l

10、ow and would be always be classed as NFPA 70E 2004, Category 0 (i.e. less than 2.00 cal/cm2)? Interpretation Response #2 The model in the Guide was empirically derived, i.e., it was developed through statistical analysis of test data. This type of model has no defined accuracy outside the range of t

11、he test data and, in fact, it can give obviously incorrect calculation results outside the stated range of the model the lower limit of 700A is based.In answer to your question on applications where the bolted fault current is below 700A, note that the Guide offers two models. The Lee Model can be a

12、pplied outside the range of the empirically derived model. Note also that Annex B suggests a limit to arc duration may be applied, depending on the application.http:/standards.ieee.org/reading/ieee/interp/1584-2002.html (2 of 4) 2009/01/06 9:09:11 PMIEEE Std 1584-2002_InterpretationRecognize that th

13、e Guide is just a guide and engineering judgment must be applied when performing an arc flash hazard calculations study. Interpretation #3 Topic: Accuracy of material in IEEE 1584-2002 and amendment IEEE 1584a-2004 Relevant Clauses: Section 9.5 and Equation 5.3(4) Section 9.5 states: “Two grounding

14、classes are applied in the equations considered, as follows: a) Ungrounded, which included ungrounded, high-resistance grounding and low-resistance grounding. b) Solidly grounded.” We have a system with a resistance grounded secondary on a 750kVA transformer. In line with the statements above, the i

15、ncident energy level determined by our software tools for the secondary side is significantly higher (about 30%) for resistance grounding than the scenario where the transformer is modeled as having solid grounding. This seems to be contrary to statements in other standards concerning resistance gro

16、unding as referenced below. Perhaps the key consideration is phase-to-ground fault versus three-phase fault. Clarification would be appreciated, since it would seem that solidly grounding the secondary would improve arc flash hazards as per above, while resistance grounding is recommended below. IEE

17、E Std 141-1993 (Red Book) section 7.2.4 states “A safety hazard exists for solidly grounded systems from the severe flash, arc burning, and blast hazard from any phase-to-ground fault.“ For this reason, IEEE recommends resistance grounding. IEEE Std 142-1991 (Green Book) section 1.4.3 states “The re

18、asons for limiting the current by resistance grounding may be one or more of the following: 1) To reduce burning and melting effects in faulted electric equipment, such as switchgear, transformers, cables, and rotating machines. 2) To reduce mechanical stresses in circuits and apparatus carrying fau

19、lt currents. 3) To reduce electric-shock hazards to personnel caused by stray ground-fault currents in the ground return path. 4) To reduce the arc blast or flash hazard to personnel who may have accidentally caused or who happen to be in close proximity to the ground fault. 5) To reduce the momenta

20、ry line-voltage dip occasioned by the clearing of a ground fault. 6) To secure control of transient over-voltages while at the same time avoiding the shutdown of a faulty circuit on the occurrence of the first ground fault (high resistance grounding). http:/standards.ieee.org/reading/ieee/interp/158

21、4-2002.html (3 of 4) 2009/01/06 9:09:11 PMIEEE Std 1584-2002_InterpretationIEEE Std 141-1993 (Red Book) section 7.2.2 states “There is no arc flash hazard, as there is with solidly grounded systems, since the fault current is limited to approximately 5A.“ Interpretation Response #3I agree with your

22、assessment that IEEE std 1584 seems to be contrary to statements in the other standards you cited, but appearances sometimes deceive. Each statement you quote from a standard is correct and your two calculations show the difference in results that I would expect.The IEEE 1584 statement is based on t

23、hree-phase testing with ungrounded and grounded systems and analysis of the results. This is because it is recognized that arc power is higher in three phase faults than in line-to-line or ground faults and single phase faults often escalate to become three-phase faults. IEEE 1584 considers only tha

24、t worst case. The other two standards you quote are discussing only ground faults, based on the fact that most faults begin as ground faults. If fault current can be limited, the fault is not likely to escalate to become a three phase fault. Arc fault energy will be quite small by comparison to the

25、three phase fault case. However, even with resistance grounding, a three phase fault is still possible and so it must be considered when calculating incident energy. Back to Available IEEE Standards Interpretations Online Copyright IEEE-SA Contact IEEE-SA For questions or comments, please contact the IEEE-SA Webmaster. http:/standards.ieee.org/reading/ieee/interp/1584-2002.html (4 of 4) 2009/01/06 9:09:11 PM

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1