IEEE 421 5 INT 1-2008 en Recommended Practice for Excitation System Models for Power System Stability Studies《IEEE Std 421 5 -2005用IEEE标准解释文件 动力系统稳定性研究用激发系统模型的I.pdf

上传人:unhappyhay135 文档编号:1248701 上传时间:2019-09-02 格式:PDF 页数:2 大小:42.09KB
下载 相关 举报
IEEE 421 5 INT 1-2008 en Recommended Practice for Excitation System Models for Power System Stability Studies《IEEE Std 421 5 -2005用IEEE标准解释文件 动力系统稳定性研究用激发系统模型的I.pdf_第1页
第1页 / 共2页
IEEE 421 5 INT 1-2008 en Recommended Practice for Excitation System Models for Power System Stability Studies《IEEE Std 421 5 -2005用IEEE标准解释文件 动力系统稳定性研究用激发系统模型的I.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、IEEE Std 421.5-2005InterpretationIEEE Standards Interpretation for IEEE Std 421.5 -2005IEEE Recommended Practice for Excitation System Models for Power System Stability Studies Copyright 2008 by the Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue New York, New York 10016-5997 U

2、SA All Rights Reserved.This is an interpretation of IEEE Std 421.5-2005. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download

3、and print one copy of this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standard Department for the appropriate license. Use of the information contained in this document is at your own risk.I

4、EEE Standards Department Copyrights and Permissions 445 Hoes Lane Piscataway, New Jersey 08855-1331, USAApril 2008Interpretation #1 Topic: Limit in Section “5: Type DC-Direct current commutator excitors“I have a question regarding IEEE Std 421.5-2005, in section “5. Type DC-Direct current commutator

5、 exciters“.All of the block diagrams in this section (Figures 5-1, 5-2, 5-3, and 5-4) have a minimum limit http:/standards.ieee.org/reading/ieee/interp/421.5-2005.html (1 of 2) 2009/01/06 7:17:24 PMIEEE Std 421.5-2005Interpretationdrawn on the 1/sTE block. However, the text does not discuss this lim

6、it at all. Figures 5-1, 5-2, and 5-3 do not even label this limit. Figure 5-4 labels it VEMIN. For the DC1A, DC2A, and DC3A models, how should this limit be implemented? What is the range of values it could have?During an extended high voltage condition, this could have an important impact on the ge

7、nerator response.Interpretation Response #1The negative limit on a dc generator is solely based on the total flux of its field windings. The cases to consider are as follows:1) Separately-excited by thyristor or PWM bridge. In this case, field current has a lower limit of 0 and this is also the lowe

8、r limit of the dc voltage.2) Self-excited dc generator with separate control windings (e.g. buck/boost). If the buck winding turns and source (e.g. mag amp) can produce enough flux to overcome the positive flux of the self-excited shunt field, then the total field can be reversed and negative output

9、 is possible.Determining this level requires either measurements or a knowledge of the turns ratio of the various field windings and the source current capability of the device feeding the buck/boost windings.I have only encountered one system where we were able to measure negative output through te

10、sting. In most cases, the buck/boost windings do not have the capacity to overcome the shunt excitation unless it is already very low.Copyright 2008 IEEE. All rights reserved.Back to Available IEEE Standards Interpretations Online Copyright IEEE-SA Contact IEEE-SA For questions or comments, please contact the IEEE-SA Webmaster. http:/standards.ieee.org/reading/ieee/interp/421.5-2005.html (2 of 2) 2009/01/06 7:17:24 PM

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1