IEEE 802 1AE INT 1-2008 Local and Metropolitan Area Networks - Media Access Control (MAC) Security - Interpretation《IEEE Std 802 1AE -2006用IEEE标准解释文件 局域网和城域网用IE.pdf

上传人:花仙子 文档编号:1248872 上传时间:2019-09-02 格式:PDF 页数:2 大小:47.11KB
下载 相关 举报
IEEE 802 1AE INT 1-2008 Local and Metropolitan Area Networks - Media Access Control (MAC) Security - Interpretation《IEEE Std 802 1AE -2006用IEEE标准解释文件 局域网和城域网用IE.pdf_第1页
第1页 / 共2页
IEEE 802 1AE INT 1-2008 Local and Metropolitan Area Networks - Media Access Control (MAC) Security - Interpretation《IEEE Std 802 1AE -2006用IEEE标准解释文件 局域网和城域网用IE.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、IEEE Std 802.1AE-2006InterpretationIEEE Standards Interpretation for IEEE Std 802.1AE -2006IEEE Standard for Local and Metropolitan Area Networks- Media Access Control (MAC) Security Copyright 2008 by the Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue New York, New York 10016-

2、5997 USA All Rights Reserved.This is an interpretation of IEEE Std 802.1AE-2006. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to d

3、ownload and print one copy of this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standard Department for the appropriate license. Use of the information contained in this document is at your ow

4、n risk.IEEE Standards Department Copyrights and Permissions 445 Hoes Lane Piscataway, New Jersey 08855-1331, USAMarch 2008Interpretation #1 Topic: Syntax error in the 802.1AE MIBIn the MIB module text of this standard, the data type secyCipherSuiteProtectionOffset is defined on page 100 as of type I

5、NTEGER and in the OBCT-TYPE macro it has a SYNTAX of Integer32. This will cause compilation errors when the MIB module is processed by the standard tools.http:/standards.ieee.org/reading/ieee/interp/802.1AE.html (1 of 2) 2009/01/06 7:32:30 PMCopyright The Institute of Electrical and Electronics Engi

6、neers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IEEE Std 802.1AE-2006InterpretationI believe that the appropriate fix for this would be to change the definition of this data type on page 100 from INTEGER to Integer

7、32.Interpretation Response #1The following response was approved by 802.1 at its November 2006 meeting. The 802.1 Working Group agrees that the proposal made in the interpretation request, namely that the appropriate solution is to change the definition of the secyCipherSuiteProtectionOffset data ty

8、pe on page 100 of the standard from INTEGER to Integer32, is correct. A corrected version of the MIB text, with this change made, has been posted on the 802.1 website at: http:/www.ieee802.org/1/files/public/MIBs/802-1ae-2006-mib-corrected.txt. Copyright 2008 IEEE. All rights reserved.Back to Availa

9、ble IEEE Standards Interpretations Online Copyright IEEE-SA Contact IEEE-SA For questions or comments, please contact the IEEE-SA Webmaster. http:/standards.ieee.org/reading/ieee/interp/802.1AE.html (2 of 2) 2009/01/06 7:32:30 PMCopyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1