IEEE C57 19 01 INT 1-2010 en Performance Characteristics and Dimensions for Outdoor Apparatus Bushings《IEEE Std C57 19 01 -2000 户外设备套管用IEEE标准性能和特征的IEEE标准解释文件》.pdf

上传人:twoload295 文档编号:1249225 上传时间:2019-09-02 格式:PDF 页数:2 大小:15.16KB
下载 相关 举报
IEEE C57 19 01 INT 1-2010 en Performance Characteristics and Dimensions for Outdoor Apparatus Bushings《IEEE Std C57 19 01 -2000 户外设备套管用IEEE标准性能和特征的IEEE标准解释文件》.pdf_第1页
第1页 / 共2页
IEEE C57 19 01 INT 1-2010 en Performance Characteristics and Dimensions for Outdoor Apparatus Bushings《IEEE Std C57 19 01 -2000 户外设备套管用IEEE标准性能和特征的IEEE标准解释文件》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、IEEE Standards Interpretations for IEEE Std C57.19.01 -2000IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings Copyright 2010 by the Institute of Electrical and Electronics Engineers, Inc. Three Park Avenue New York, New York 10016-5997 USA All Rights Reserved. Th

2、is is an interpretation of IEEE Std C57.19.01-2000. Interpretations are issued to explain and clarify the intent of a standard and are not intended to constitute an alteration to the original standard or to supply consulting information. Permission is hereby granted to download and print one copy of

3、 this document. Individuals seeking permission to reproduce and/or distribute this document in its entirety or portions of this document must contact the IEEE Standards Department for the appropriate license. Use of the information contained in this document is at your own risk. IEEE Standards Depar

4、tment Copyrights and Permissions 445 Hoes Lane, P. O. Box 1331 Piscataway, New Jersey 08855-1331, USA August 2010 Interpretation Request #1 Topic: C1 or C power factor Clause, Subclause, Annex, Figure, or Table: Table 6 IEEE Std C57.19.00-2004 establishes in 7.4.2 regarding power factor tests: “Limi

5、ts and tolerance of acceptable change are specified in Table 6 of IEEE Std C57.19.01.” Table 6 specifies limits for C1 or C power factor for different types of construction - the interpretation request is about the 0.5% power factor limit for Oil-impregnated, paper insulated type. Does this limit (a

6、nd table) apply for new equipment only? Apparently, there is a conflict with IEEE Std 62-1995, which recommends in 6.2.4: “In practice, if the power factor of capacitance-graded bushings exceeds 1%, the user should seek further specialized help.” Such statement Page 1 of 2IEEE Std C57.19.01-20008/23

7、/2010file:/A:AcquisitionIEEE Errata, IEEE Intp & NESC Intp08232010C57_19_01-2000_In.implies that values of power factor below 1% are, at least, acceptable. Doesnt it?Interpretation Response #1 IEEE bushing standards - IEEE Std C57.19.00-2004 and IEEE Std C57.19.01-2000 - apply to new bushings. Other

8、 standards such as IEEE Std C57.19.100-1995 and IEEE Std 62-1995 contain information addressing testing of in-service bushings and interpretation of the test results. . Back to Available IEEE Standards Interpretations Online Copyright IEEE-SA Contact IEEE-SA For questions or comments, please contact the IEEE-SA Webmaster. Page 2 of 2IEEE Std C57.19.01-20008/23/2010file:/A:AcquisitionIEEE Errata, IEEE Intp & NESC Intp08232010C57_19_01-2000_In.

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1