IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf

上传人:bonesoil321 文档编号:1249371 上传时间:2019-09-02 格式:PDF 页数:11 大小:260.03KB
下载 相关 举报
IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf_第1页
第1页 / 共11页
IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf_第2页
第2页 / 共11页
IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf_第3页
第3页 / 共11页
IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf_第4页
第4页 / 共11页
IEEE NESCIR569-2012 en National Electrical Safety Code《国家电气安全规范》.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、 1 Copyright 2012 IEEE. All rights reserved. Interpretation Section 21. General requirements Rule 215C4b Grounding of circuits, supporting structures, and equipment - Non-current-carrying parts - Use of insulators in anchor guys (2012 Edition, pages 75-76) (2 October 2012) IR569 For dead-end and per

2、pendicular (not parallel) down guys, does Rule 215C4b in the 2012 edition require guy insulators to be installed to fall in between all circuits on that structure if the down guy breaks below the insulator? The 2012 revised version of this Rule states the condition of this requirement to be “. . .in

3、 the event that the anchor guy becomes slack.” Discussion: It is believed that Rule 215C4b in the 2012 edition DOES NOT require guy insulators to be installed to fall in between all circuits on that structure if the down guy breaks below the insulator on dead-end and perpendicular (not parallel) dow

4、n guys. The belief is that the guy insulator placement configuration examples shown in the attached Figure 1 through Figure 8 meet the intent of NESC Rule 215C4. However, at a recent 2012 NESC Changes seminar, it was presented that these are all violations (citing 215C4b) because no insulation is in

5、stalled to fall between the distribution primary and the secondary circuits. It is not believed that 215C4b is applicable to these installations because the Rule refers to the guy becoming slack, not broken. In none of these instances will a slacked guy become a conductive path between energized con

6、ductors or live parts of other circuits or equipment. It is the belief (interpretation) that the Figure 9 guy insulator placement configuration attached represents the intent of NESC Rule 215C4b and 215C4c. In this example, sagging guys can present a safety (and reliability) hazard if the guy insula

7、tors are not located properly. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 2 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 3 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 4 Copyright 2012 IEEE. All rights reserv

8、ed. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 5 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 6 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 7 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAF

9、ETY CODE INTERPRETATION 8 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 9 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 10 Copyright 2012 IEEE. All rights reserved. NATIONAL ELECTRICAL SAFETY CODE INTERPRETATION 11

10、 Copyright 2012 IEEE. All rights reserved. Interpretation The Interpretations Subcommittee has considered the subject Interpretation Request for Rule 215C4b and has developed a consensus report as follows: Rule 215C4b does not apply to specific design configurations, but applies to any design config

11、uration. The intent of this Rule is to limit the likelihood of voltage transfer between facilities due to a slack or broken anchor guy. Even though the Rule only uses the word slack to describe how voltage could be transferred, it also applies to broken guys since a broken guy is the ultimate in bei

12、ng slack. Note that the Rule is a performance rule, not specific to configuration (dead-end, perpendicular, parallel, etc.) or to clearance requirements. _ National Electrical Safety Code and NESC are both registered trademarks and service marks of the Institute of Electrical and Electronics Engineers, Inc. The NESC is available from the Institute of Electrical and Electronics Engineers, Inc., 445 Hoes Lane, Piscataway, NJ 08854, USA (http:/standards.ieee.org/)

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1