ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf

上传人:fatcommittee260 文档编号:1255238 上传时间:2019-09-02 格式:PDF 页数:56 大小:511KB
下载 相关 举报
ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf_第1页
第1页 / 共56页
ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf_第2页
第2页 / 共56页
ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf_第3页
第3页 / 共56页
ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf_第4页
第4页 / 共56页
ISO 7240-16-2007 Fire detection and alarm systems - Part 16 Sound system control and indicating equipment《火灾探测和报警系统 第16部分 声音系统控制和指示设备》.pdf_第5页
第5页 / 共56页
点击查看更多>>
资源描述

1、 Reference number ISO 7240-16:2007(E) ISO 2007INTERNATIONAL STANDARD ISO 7240-16 First edition 2007-07-01 Fire detection and alarm systems Part 16: Sound system control and indicating equipment Systmes de dtection et dalarme dincendie Partie 16: quipement de contrle et de signalisation des systmes s

2、onores ISO 7240-16:2007(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing.

3、 In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be foun

4、d in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the

5、address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2007 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either

6、 ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2007 All rights reservedISO 7240-16:2007(E) ISO 2

7、007 All rights reserved iii Contents Page Foreword vi Introduction . viii 1 Scope . 1 2 Normative references . 1 3 Terms, definitions and abbreviated terms . 3 3.1 Terms and definitions. 3 3.2 Abbreviations 4 4 General requirements. 4 4.1 General. 4 4.2 Combined s.s.c.i.e. and c.i.e 4 4.3 Power supp

8、ly. 4 5 General requirements for indications. 4 5.1 Display of functional conditions . 4 5.2 Display of indications. 5 5.3 Indications on alphanumeric displays 5 5.4 Indication of the supply of power . 5 5.5 Additional indications 5 6 Quiescent condition . 5 7 Voice-alarm condition 6 7.1 Reception a

9、nd processing of alarm signal 6 7.2 Alert signal Optional function 6 7.3 Evacuate signal. 6 7.4 Indication of the voice-alarm condition 6 7.5 Audible warning Optional function 7 7.6 Delay before entering the voice-alarm condition Optional function 7 7.7 Phased evacuation Optional function . 7 7.8 Si

10、lencing the voice-alarm condition . 8 7.9 Reset of the voice-alarm condition. 8 7.10 Output to alarm devices Optional function.8 7.11 Voice-alarm condition output signal Optional function. 8 8 Fault-warning condition . 9 8.1 Reception and processing of fault signals 9 8.2 Indication of faults in spe

11、cified functions 9 8.3 System fault. 10 8.4 Audible indication. 10 8.5 Reset of fault indications . 11 8.6 Fault-warning condition output signal . 11 9 Disabled condition Optional function 11 9.1 General. 11 9.2 Indication of the disabled condition . 11 9.3 Indication of specific disablements 11 9.4

12、 Disablement condition output Optional function. 12 10 Test condition Optional function . 12 10.1 General. 12 10.2 Indication of the test condition . 12 10.3 Indication of specific emergency loudspeaker zones in the test state. 12 ISO 7240-16:2007(E) iv ISO 2007 All rights reserved11 Manual mode con

13、trol Optional function 12 11.1 General . 12 11.2 Indications of emergency loudspeaker zones in the voice-alarm condition 13 11.3 Indication of emergency loudspeaker zones in the fault-warning condition Optional function 13 11.4 Indication of emergency loudspeaker zones in the disabled condition Opti

14、onal function . 13 12 Interface to external control device(s) Optional function 13 13 Emergency microphone Optional function . 14 13.1 General . 14 13.2 Microphone priority Optional function 14 13.3 Microphone emergency loudspeaker zone control Optional function. 14 14 Design requirements 14 14.1 Ge

15、neral requirements and manufacturers declarations 14 14.2 Documentation 15 14.3 Mechanical design requirements 15 14.4 Electrical and other design requirements 16 14.5 Integrity of transmission paths 16 14.6 Accessibility of indications and controls . 16 14.7 Indications by means of light-emitting i

16、ndicators. 17 14.8 Indications on alphanumeric displays 17 14.9 Colours of indications 18 14.10 Audible indications . 18 14.11 Testing of indicators. 18 14.12 Audio performance . 18 14.13 Message store . 20 14.14 Redundant power amplifiers Optional function 20 15 Additional design requirements for s

17、oftware-controlled s.s.c.i.e 21 15.1 General requirements and manufacturers declarations 21 15.2 Software documentation 21 15.3 Software design 22 15.4 Program monitoring 22 15.5 The storage of programs and data 22 15.6 Monitoring of memory contents 23 16 Marking. 23 17 Tests. 23 17.1 General . 23 1

18、7.2 Functional test. 24 17.3 Test schedule 27 17.4 Output power. 28 17.5 Signal-to-noise ratio . 29 17.6 Frequency response of s.s.c.i.e. without microphone(s) . 30 17.7 Frequency response of s.s.c.i.e. with microphone(s) . 31 17.8 Cold (operational) . 32 17.9 Damp heat, steady state (operational) 3

19、3 17.10 Damp heat, steady state (endurance) . 34 17.11 Impact (operational) 35 17.12 Vibration, sinusoidal (operational) 36 17.13 Vibration, sinusoidal (endurance) . 37 17.14 Supply voltage variation (operational) 38 17.15 Electromagnetic compatibility (EMC), immunity tests (operational). 39 18 Test

20、 report 40 Annex A (informative) Use of optional functions 41 Annex B (informative) Common indications, controls and outputs when the s.s.c.i.e. and the c.i.e. are combined. 43 Annex C (informative) Interface between the s.s.c.i.e. and the emergency-detection system. 44 ISO 7240-16:2007(E) ISO 2007

21、All rights reserved v Annex D (informative) Explanation of access levels 45 Annex E (informative) Design requirements for software-controlled s.s.c.i.e. 47 ISO 7240-16:2007(E) vi ISO 2007 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation o

22、f national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. In

23、ternational organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with

24、the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval

25、 by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 7240-16 was prepared by Technical Committe

26、e ISO/TC 21, Equipment for fire protection and fire fighting, Subcommittee SC 3, Fire detection and alarm systems. This first edition of ISO 7240-16 together with ISO 7240-19 cancels and replaces IEC 60849:1998, which has been technically revised. ISO 7240 consists of the following parts, under the

27、general title Fire detection and alarm systems: Part 1: General and definitions Part 2: Control and indicating equipment Part 4: Power supply equipment Part 5: Point-type heat detectors Part 6: Carbon monoxide fire detectors using electro-chemical cells Part 7: Point-type smoke detectors using scatt

28、ered light, transmitted light or ionization Part 8: Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor Part 9: Test fires for fire detectors (Technical Specification) Part 10: Point-type flame detectors Part 11: Manual call points Part 12: Line type smoke

29、 detectors using a transmitted optical beam Part 13: Compatibility assessment of system components Part 14: Guidelines for drafting codes of practice for design, installation and use of fire detection and fire alarm systems in and around buildings (Technical Report) ISO 7240-16:2007(E) ISO 2007 All

30、rights reserved vii Part 15: Point type fire detectors using scattered light, transmitted light or ionization sensors in combination with a heat sensor Part 16: Sound system control and indicating equipment Part 19: Design, installation, commissioning and service of sound systems for emergency purpo

31、ses Part 21: Routing equipment Part 22: Smoke-detection equipment for ducts Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor A part 26 dealing with oil mist detectors and a part

32、28 dealing with fire protection control equipment are under development. ISO 7240-16:2007(E) viii ISO 2007 All rights reservedIntroduction Sound system control and indicating equipment (s.s.c.i.e.) forms part of a sound system for emergency purposes (s.s.e.p.). An s.s.e.p. operates automatically or

33、manually in a building or structure to alert occupants to a hazard which may require their evacuation in a safe and orderly manner. Equipment to warn occupants is therefore required to function after the hazard has been detected. Fire in a building is a common hazard which is often detected by an au

34、tomatic fire detection and alarm system. An s.s.e.p. may operate as part of a fire detection and alarm system or may function in conjunction with other emergency detection systems, such as those for storms, earthquakes and bomb threats. The s.s.c.i.e. may be a separate unit or may be physically comb

35、ined with the fire detection control and indicating equipment (see ISO 7240-2). This part of ISO 7240 has been prepared by Subcommittee ISO/TC 21/SC 3 and is based on IEC 60849:1998, Sound systems for emergency purposes, prepared by the International Electrotechnical Commission IEC/TC 100, Audio, vi

36、deo and multimedia systems and equipment. This part of ISO 7240 follows the format of, and has similar requirements to, ISO 7240-2 and is drafted on the basis of mandatory functions which are to be provided on all s.s.c.i.e. and optional functions (with requirements) which may be provided. Each opti

37、onal function is included as a separate entity, with its own set of associated requirements, in order for s.s.c.i.e. with different combinations of functions to comply with this part of ISO 7240. It is intended that the options be used for specific applications, as recommended in ISO 7240-19 and the

38、 emergency management plan. Other functions associated with an s.s.e.p. may also be provided, even if they are not specified in this part of ISO 7240. This part of ISO 7240 contains specific tests that subject the equipment to conditions likely to be met in practice, such as corrosion, vibration, di

39、rect impact, indirect shock and electromagnetic interference. Some tests specified are intended to assess the performance of the s.s.c.i.e. under such conditions. The performance of the s.s.c.i.e. is assessed from the results obtained in specific tests. This part of ISO 7240 is not intended to place

40、 any other restrictions on the design and construction of such equipment. INTERNATIONAL STANDARD ISO 7240-16:2007(E) ISO 2007 All rights reserved 1 Fire detection and alarm systems Part 16: Sound system control and indicating equipment 1 Scope This part of ISO 7240 specifies the requirements, test m

41、ethods and performance criteria for sound system control and indicating equipment (s.s.c.i.e.) for use in buildings and structures as part of a sound system for emergency purposes (s.s.e.p.) (item C of Figure 2 in ISO 7240-1:2005). The s.s.c.i.e. is primarily intended to broadcast information for th

42、e protection of lives within one or more specified areas in an emergency, to effect a rapid and orderly mobilization of occupants in an indoor or outdoor area. This includes systems using loudspeakers to broadcast voice announcements for emergency purposes, alert signals complying with ISO 7731, and

43、 evacuate signals complying with ISO 8201. The overall requirements of an s.s.e.p., especially concerning audibility and intelligibility, are contained within ISO 7240-19. In addition to ensuring compliance with this part of ISO 7240, the manufacturer should also consider the requirements of ISO 724

44、0-19, national regulations, codes and standards that affect the s.s.c.i.e. design and usability. For example, some regulations require certain optional functions to be available on all s.s.c.i.e. installed within the jurisdiction. The use of the equipment for normal sound reinforcement and distribut

45、ion systems purposes under non- hazardous circumstances is not excluded. This part of ISO 7240 can also be used for the assessment of similar control and indicating equipment for use in systems where the warning-signal broadcast does not include a voice message. This part of ISO 7240 does not apply

46、to systems using only sounders or bells. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendm

47、ents) applies. ISO 7240-1:2005, Fire detection and alarm systems Part 1: General and definitions ISO 7240-2:2003, Fire detection and alarm systems Part 2: Control and indicating equipment ISO 7240-4:2003, Fire detection and alarm systems Part 4: Power supply equipment ISO 7240-5, Fire detection and

48、alarm systems Part 5: Point-type heat detectors ISO 7240-6, Fire detection and alarm systems Part 6: Carbon monoxide fire detectors using electro- chemical cells ISO 7240-7, Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization ISO

49、 7240-16:2007(E) 2 ISO 2007 All rights reservedISO 7240-8, Fire detection and alarm systems Part 8: Carbon monoxide fire detectors using an electro- chemical cell in combination with a heat sensor ISO/TS 7240-9, Fire detection and alarm systems Part 9: Test fires for fire detectors ISO 7240-10, Fire detection and alarm systems Part 10: Point-type flame detectors ISO 7240-11, Fire detection and alarm systems Part 11: Manual call points ISO 7240-