1、 IEC 62230 Edition 1.0 2013-11 INTERNATIONAL STANDARD NORME INTERNATIONALE Electric cables Spark-test method Cbles lectriques Mthode dessai au dfilement sec (sparker) IEC62230:2006/A1:2013AMENDMENT 1 AMENDEMENT 1 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2013 IEC, Geneva, Switzerland All rig

2、hts reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the reque

3、ster. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune partie

4、de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright d

5、e la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Geneva 20 infoiec.ch Switze

6、rland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept

7、under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: IEC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a variety of criteria (reference numbe

8、r, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available on-line and also once a month by

9、 email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary (IEV

10、) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la premire organisation mond

11、iale qui labore et publie des Normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldition la plus rcente, un

12、 corrigendum ou amendement peut avoir t publi. Liens utiles: Recherche de publications CEI - www.iec.ch/searchpub La recherche avance vous permet de trouver des publications CEI en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Elle donne aussi des informations sur les projets

13、 et les publications remplaces ou retires. Just Published CEI - webstore.iec.ch/justpublished Restez inform sur les nouvelles publications de la CEI. Just Published dtaille les nouvelles publications parues. Disponible en ligne et aussi une fois par mois par email. Electropedia - www.electropedia.or

14、g Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 30 000 termes et dfinitions en anglais et en franais, ainsi que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique International (VEI) en ligne. Serv

15、ice Clients - webstore.iec.ch/csc Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions contactez-nous: csciec.ch. IEC 62230 Edition 1.0 2013-11 INTERNATIONAL STANDARD NORME INTERNATIONALE Electric cables Spark-test method Cbles lectriques Mthode dessai au d

16、filement sec (sparker) INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE E ICS 29.060.20 PRICE CODE CODE PRIX ISBN 978-2-8322-1207-3 AMENDMENT 1 AMENDEMENT 1 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electro

17、technique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agr. 2 62230 Amend. 1 IEC:2013 FOREWORD This amendment has been prepared by IEC technical committ

18、ee 20: Electric Cables. The text of this amendment is based on the following documents: FDIS Report on voting 20/1462/FDIS 20/1470/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table. The committee has decided that t

19、he contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. _ Conte

20、nts Replace the existing title of Annex A by the following: Annex A (normative) Minimum voltage levels Replace the existing title of Table A.1 by the following: Table A.1 Minimum spark-test voltages for cables having rated voltage (U0) between 300 V and 3 000 V 1 Scope Replace, in the second sentenc

21、e of the first paragraph, the term “single core cables“ by “single-core cables“. 3 Procedure Replace the existing third paragraph by the following: When used as an alternative to a voltage test in water, the test shall be restricted to layer thicknesses not greater than 2,0 mm unless otherwise speci

22、fied in the cable standard. Only the a.c. or d.c. voltage waveforms shall be used. Replace, in the fifth paragraph, the phrase “recommended voltages“ by “minimum voltages“. 62230 Amend. 1 IEC:2013 3 5 Test voltages Replace the existing fourth paragraph by the following: Where a cable standard states

23、 the test voltages, these shall be used. In the absence of such specified voltages, the test voltages given in Annex A shall be used. 6 Sensitivity 6.1 AC, d.c. and h.f. voltages Delete the second sentence of the first paragraph. Replace the existing text of the second paragraph with the following:

24、Equipment shall be capable of detecting the faults described in 6.1.1 and 6.1.2 and shall be verified according to 6.3. 6.1.1 AC and h.f. Replace the beginning of the existing text (“The typical fault is defined“) as follows: A fault is defined . 6.1.2 DC Replace the beginning of the existing text (

25、“The typical fault is defined“) as follows: A fault is defined . 6.2 Pulsed voltages Delete, in the first paragraph, the word “typical“. Replace the beginning of the second paragraph (“The typical fault is defined“) as follows: A fault is defined . 4 62230 Amend. 1 IEC:2013 Annex A Recommended minim

26、um voltage levels Replace the existing title and text of the annex as follows: Annex A (normative) Minimum voltage levels A.1 General The test voltages given in Table A.1 shall be used, unless the cable standard specifies alternative test voltages. The details of the test method are as given in the

27、main section of this standard. A.2 Test voltages A.2.1 General The voltages given in Annex A are the minimum levels to be used to locate defects in the layer under test. These levels shall only be reduced if specified in the relevant cable standard. NOTE Some countries have established higher test l

28、evels in their national standards. A.2.2 Contact electrodes The high-voltage supply to the test electrode may be a.c., d.c., h.f. or pulsed voltage, as specified in Clause 2 and 4.2. Table A.1 gives test voltages for cables having a rated voltage (U0) between 300 V and 3 000 V. 62230 Amend. 1 IEC:20

29、13 5 Table A.1 Minimum spark-test voltages for cables having rated voltage (U0) between 300 V and 3 000 V Tabulated radial thickness of layer under test mm Test voltage kV Above Up to and including a.c.ad.c. h.f.aPulse a0 0,25 3 5 4 5 0,25 0,50 5 7 6 7 0,50 0,75 6 9 7 9 0,75 1,00 7 11 8 11 1,00 1,25

30、 9 13 10 b13 1,25 1,50 10 15 11 b15 1,50 1,75 12 17 13 b17 1,75 2,00 13 20 14 b20 2,00 2,25 14 22 15 b2,25 2,50 16 24 17 b2,50 2,75 17 26 18 b2,75 3,00 19 28 20 b3,00 3,25 21 32 3,25 3,50 23 35 3,50 - 25 38 aThe a.c. and h.f. test voltages are r.m.s. values, the pulse test voltage is the peak value.

31、 bHF voltage testing for layer thicknesses greater than 1,0 mm shall be limited to frequencies between 500 Hz and 4 kHz. NOTE 1 The tabulated radial thickness is either the nominal thickness calculated in accordance with the relevant cable standard or the thickness specified in the constructional ta

32、ble of the relevant cable standard whichever is applicable. Pulsed voltage testing shall not be used for layer thicknesses greater than 2,0 mm. As a test to replace the traditional voltage test in water for single-core cables without any outer metallic layer, Table A.1 only applies for thicknesses n

33、ot greater than 2,0 mm and only the a.c. or d.c. voltage waveform shall be used. When testing laid-up core assemblies, i.e. cables without sheath, the test voltage level shall be that for the lowest individual insulation thickness in the assembly. NOTE 2 Particular cable standards may, in exceptiona

34、l circumstances (e.g. for sheathing materials known to exhibit low insulation resistance characteristics, i.e. Kiless than 100 M.km), require a reduction in the test voltage to ensure that excessive leakage current does not flow and give rise to spurious faults. In no instance will the reduction be

35、in excess of a factor of two and the fault detection system will be verified under the alternative test conditions. A.2.3 Non-contact electrodes The high-voltage supply to the test electrode shall be d.c. only, as defined in 4.2. The conductor of the core or the metallic layer under the sheath shall

36、 be continuously earthed and the potential difference between the electrode and the conductor or the metallic layer shall be 18 kV. _ 6 62230 Amend. 1 CEI:2013 AVANT-PROPOS Le prsent amendement a t tabli par le comit dtudes 20 de la CEI: Cbles lectriques. Le texte de cet amendement est issu des docu

37、ments suivants: FDIS Rapport de vote 20/1462/FDIS 20/1470/RVD Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant abouti lapprobation de cet amendement. Le comit a dcid que le contenu de cet amendement et de la publication de base ne sera pas modifi avant la

38、 date de stabilit indique sur le site web de la CEI sous “http:/webstore.iec.ch“ dans les donnes relatives la publication recherche. A cette date, la publication sera reconduite, supprime, remplace par une dition rvise, ou amende. _ Contenu Remplacer le titre existant de lAnnexe A par ce qui suit: A

39、nnexe A (normative) Niveaux de tension minimaux Remplacer le titre existant du Tableau A.1 par ce qui suit: Tableau A.1 Tensions minimales dessai au sparker pour les cbles de tension nominale (U0) comprise entre 300 V et 3 000 V 1 Domaine dapplication a) Dans la version anglaise uniquement, dans la

40、deuximephrase du premier alina, remplacer le terme “single core cables“ par “single-core cables“. 3 Mthode Remplacer le troisime alina existant par le suivant: Lorsquil est utilis comme alternative un essai de tension dans leau, lessai doit tre limit aux paisseurs de gaine infrieures ou gales 2,0 mm

41、, sauf spcification contraire dans la norme de cble. Seules les formes dondes de tension en courant alternatif et en courant continu doivent tre utilises. 62230 Amend. 1 CEI:2013 7 Remplacer, dans le cinquime alina, les mots “tensions recommandes“ par “tensions minimales“. 5 Tensions dessai Remplace

42、r le quatrime alina existant par le suivant: Quand la norme de cble concerne spcifie les tensions dessai, celles-ci doivent tre utilises. En cas dabsence de tensions spcifies, les tensions dessai donnes lAnnexe A doivent tre utilises. 6 Sensibilit 6.1 Tensions en courant alternatif, en courant conti

43、nu et haute frquence Supprimer la deuxime phrase du premier alina. Remplacer le texte du deuxime alina par le texte suivant: Lquipement doit tre en mesure de dtecter les dfauts dcrits en 6.1.1 et 6.1.2 et il doit tre vrifi conformment au 6.3. 6.1.1 Courant alternatif et haute frquence Remplacer le d

44、but du texte existant (“Le dfaut type est dfini “) comme suit: Un dfaut est dfini . 6.1.2 Courant continu Remplacer le dbut du texte existant (“Le dfaut type est dfini “) comme suit: Un dfaut est dfini . 6.2 Tensions avec impulsion Supprimer, dans le premier alina, le mot “type“.: Remplacer le dbut

45、du deuxime alina (“Le dfaut type est dfini “) comme suit: Un dfaut est dfini . 8 62230 Amend. 1 CEI:2013 Annexe A Niveaux de tension minimaux recommands Remplacer le titre et le texte existants de lannexe par ce qui suit: Annexe A (normative) Niveaux de tension minimaux A.1 Gnralits Les tensions des

46、sai indiques dans le Tableau A.1 doivent tre utilises lorsquaucune tension alternative nest spcifie dans la norme du cble concerne. La mthode dessai dtaille est indique dans la section principale de la prsente norme. A.2 Tensions dessai A.2.1 Gnralits Les tensions indiques dans lAnnexe A sont les ni

47、veaux minimaux utiliser pour localiser des dfauts dans la couche soumise lessai. Ces niveaux ne doivent tre rduits que si cela est spcifi dans la norme de cble concerne. NOTE Certains pays ont fix dans leurs normes nationales des niveaux dessai plus levs. A.2.2 Electrodes de contact Lalimentation ha

48、ute tension de llectrode dessai peut tre en courant alternatif, en courant continu, haute frquence ou en tension avec impulsion, comme spcifi lArticle 2 et en 4.2. Le Tableau A.1 indique les tensions dessai pour les cbles ayant une tension nominale (U0) comprise entre 300 V et 3 000 V. 62230 Amend. 1 CEI:2013 9 Tableau A.1 Tensions minimales dessai au sparker pour les cbles de tension nominale (U0) comprise entre 300 V et 3 000 V paisseur radiale compile de la couche en essai mm Tension des

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1