ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf

上传人:孙刚 文档编号:349547 上传时间:2019-07-20 格式:PDF 页数:9 大小:183.27KB
下载 相关 举报
ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf_第1页
第1页 / 共9页
ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf_第2页
第2页 / 共9页
ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf_第3页
第3页 / 共9页
ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf_第4页
第4页 / 共9页
ASTM D4727 D4727M-17 Standard Specification for Corrugated and Solid Fiberboard Sheet Stock (Container Grade) and Cut Shapes.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D4727/D4727M 17Standard Specification forCorrugated and Solid Fiberboard Sheet Stock (ContainerGrade) and Cut Shapes1This standard is issued under the fixed designation D4727/D4727M; the number immediately following the designation indicates theyear of original adoption or, in the case

2、of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This s

3、pecification covers fiberboard primarily used forthe fabrication of boxes and interior details such as pads,sleeves, liners, partitions, die-cut sheets, etc.1.2 The performance of fiberboard boxes is largely depen-dent on the paper components from which they are fabricatedand, in the case of corruga

4、ted boxes, on the flute structure aswell. Therefore, a variety of grades reflecting varied perfor-mance levels are specified.1.3 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The values stated in

5、 eachsystem are not exact equivalents; therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.See IEEE/ASTM-SI-10 for conversion of units.1.4 The following safety hazards caveat pertains only to thetest port

6、ion, Sections 8 and 9, of this specification:Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory lim

7、ita-tions prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organizati

8、on TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D585 Practice for Sampling and Accepting a Single Lot ofPaper, Paperboard, Fiberboard, and Related Product(Withdrawn 2010)3D996 Terminology of Packaging and Distribution Environ-mentsD3950 Specification for Stra

9、pping, Nonmetallic (and Join-ing Methods)D3951 Practice for Commercial PackagingD3953 Specification for Strapping, Flat Steel and SealsD4169 Practice for Performance Testing of Shipping Con-tainers and SystemsD4675 Guide for Selection and Use of Flat Strapping Ma-terials1D5118/D5118M Practice for Fa

10、brication of Fiberboard Ship-ping BoxesD5168 Practice for Fabrication and Closure of Triple-WallCorrugated Fiberboard ContainersD5639/D5639M Practice for Selection of Corrugated Fiber-board Materials and Box Construction Based on Perfor-mance RequirementsD6039/D6039M Specification for Open and Cover

11、ed WoodCratesD6199 Practice for Quality of Wood Members of Containersand PalletsE162 Test Method for Surface Flammability of MaterialsUsing a Radiant Heat Energy SourceE662 Test Method for Specific Optical Density of SmokeGenerated by Solid Materials1This specification is under the jurisdiction of A

12、STM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.27 on FiberboardShipping Containers, Containerboard and Related Structures and Materials.Current edition approved April 1, 2017. Published June 2017. Originallyapproved in 1987. Last previous edition approved in 2015

13、as D4727/D4727M 151. DOI: 10.1520/D4727_D4727M-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last a

14、pproved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in acco

15、rdance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1IEEE/ASTM-SI-10 Standard for Us

16、e of the InternationalSystem of Units (SI): The Modern Metric System2.2 TAPPI Standards:4T 402 Standard Conditioning and Testing AtmosphereT 410 Weight per Unit Area (Basis Weight or Substance)T411Thickness (Caliper) of Paper and PaperboardT 441 Water Absorptiveness of Sized (Non-Bibulous) Paperand

17、Paperboard (Cobb Test)T 803 Puncture and Stiffness Test of Container BoardT 810 Bursting Strength of Corrugated and Solid FiberboardT811Edge Crush TestT 812 Ply Separation of Solid and Corrugated Fiberboard(Wet)2.3 Other Standards:National Motor Freight Classification5Uniform Freight Classification6

18、ISO 535 Paper and BoardDetermination of WaterAbsorptionCobb Method73. Terminology3.1 General definitions for packaging and distribution envi-ronments are found in Terminology D996.4. Classification4.1 TypeCorrugated fiberboard (CF).4.1.1 ClassesDomestic (D) and domestic/fire retardant(D/FR).4.1.1.1

19、VarietySinglewall (SW).(1) Burst Grades125, 150, 175, 200, 250, 275, and 350.8(2) ECT Grades23, 26, 29, 32, 40, 44, and 5594.1.1.2 VarietyDoublewall (DW).(1) Burst Grades200, 275, 350, 400, 500 and 600.8(2) ECT Grades42, 48, 51X, 61X, 71X, and 82X.9,104.1.1.3 VarietyTriplewall (TW).(1) Grades700, 90

20、0, 1100, and 1300.114.1.2 ClassesWeather-resistant (WR) and weather-resistant/fire retardant (WR/FR).4.1.2.1 VarietySinglewall (SW).(1) GradesV3c, and W5c.4.1.2.2 VarietyDoublewall (DW).(1) GradesV11c, V13c, and V15c4.1.3 ClassesWater and water-vapor resistant (WWVR)and water and water-vapor resista

21、nt/fire retardant (WWVR/FR).4.1.3.1 VarietySinglewall (SW).(1) GradesV3c WWVR, W5c WWVR.4.1.3.2 VarietyDoublewall (DW).(1) GradesV11c WWVR and V13c WWVR.4.2 TypeSolid Fiberboard (SF).4.2.1 ClassDomestic (D) and Domestic/Fire Retardant(D/FR).4.2.1.1 Grades125, 175, 200, 275, 350, 500 and 600.84.2.2 C

22、lassWeather-resistant (WR) and WeatherResistant/Fire Retardant (WR/FR).4.2.2.1 GradesV2s, V3s, V4s, W5s and W6s.5. Ordering Information5.1 Purchasers should select the preferred options permittedherein, and include the following information in procurementdocuments:5.1.1 Title, number and date of thi

23、s specification,5.1.2 Type, class, variety and grade (see 4.1 and 7.1),5.1.3 Size of sheet, pad, etc. (see 7.3.1.4),5.1.4 Center line of score to center line of score or sheetedge (see 7.3.1.4),5.1.5 Flute design of type corrugated fiberboard; variety SWand DW (see 6.4 and 6.4.1),5.1.6 Mill run or t

24、rimmed sheets,5.1.7 Dimensional direction of flutes of type CorrugatedFiberboard (CF),5.1.8 Packing and marking requirements (see S3 and S4),and5.1.9 Palletization requirements (see S3.1.1.1).6. Materials and ManufactureMATERIALS6.1 Paperboard Components:6.1.1 Facings and Outer PliesThe facings of c

25、orrugatedfiberboard and the plies of solid fiberboard shall have bendingqualities to satisfy the requirements of 7.6. The paperboardcomponents of weather-resistant class material shall be treatedwith a suitable wet strength resin to make them water resistant.Similarly, the paperboard components of f

26、ire retardant classmaterial shall be treated to make them fire retardant to meet therequirements of 7.7.1 and 7.7.2.6.1.1.1 Outer Facing of Corrugated Fiberboard, Water- andWater Vapor Resistant ClassOne outer facing of this materialshall be a composite sheet comprised of one ply of sized, wetstreng

27、th kraft linerboard laminated to a ply of linerboardconforming to 6.1.1 with a minimum of 6 lb/1000 ft229 g/m2of polyethylene. The sized ply shall be on the exterior side ofthe facing, with the unsized linerboard next to the corrugatedmedium. At the suppliers option, both plies of linerboard maybe o

28、f a sized wet strength material.6.1.1.2 Facing and Outer Plies Pertaining to HazardousMaterials PackagingThe facings of corrugated fiberboardand the plies of solid fiberboard shall have water resistancequalities to satisfy the following requirement from ISO 535:4Available from Technological Associat

29、ion of the Pulp and Paper Industry(TAPPI), 15 Technology Parkway South, Suite 115, Peachtree Corners, GA 30092,http:/www.tappi.org.5National Motor Freight Classification is available from National Motor FreightTraffic Association, Inc. (NMFTA), 1001 N. Fairfax St., Suite 600, Alexandria, VA22314-179

30、8, http:/www.nmfta.org.6Uniform Freight Classification is available from Rail Publication Service, 151Ellis St. N.E., Suite 260, Atlanta, GA 303356021.7Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.8Grade numbers for sin

31、gle and double wall corrugated varieties and solid fibertypes refer to the bursting strength in lb/in.2as determined by TAPPI T 810.9Grade numbers for single and double wall corrugated varieties refer to the edgecrush in lb/in. as determined by TAPPI T 811.10Grade numbers for double wall corrugated

32、varieties with an “X” indicate thatthe value should be used as a guide and that the actual required edge crush test valueis yet to be determined.11Grade number for triplewall refers to the dry puncture resistance in units asdetermined by TAPPI T 803.D4727/D4727M 172(1) Water resistance of the outer

33、surface shall be such thatthe increase in mass, as determined in a test carried out over aperiod of 30 min by the Cobb test method of determining waterabsorption, is not greater than 155 g/m2.6.1.2 Corrugated Medium(1) The corrugating medium of corrugated fiberboard shallbe made from any suitable fi

34、bers.(2) The corrugating medium components of Weather Re-sistant classes and the Water and Water Vapor Resistant classesshall be treated with a suitable wet strength resin to make themwater resistant.6.2 Adhesives:6.2.1 Domestic (D) and Domestic/Fire Retardant (D/FR)ClassesThe adhesive used in the c

35、onstruction of thedomestic/fire retardant class of fiberboard should be that whichis commercially used by the industry, and shall enable the enditem to meet the strength requirements specified herein.6.2.2 Weather-Resistant (WR) and Weather-Resistant/FireRetardant (WR/FR) ClassesThe adhesive used in

36、 the con-struction of Weather-Resistant classes of fiberboard shall bewater-resistant to the extent that the end item will meet therequirements of this specification (see 7.4).6.2.3 Water and Water Vapor-Resistant (WWVR) and Waterand Water Vapor-Resistant/Fire Retardant (WWVR/FR)ClassesThe adhesive

37、used in the construction of Water andWater Vapor-Resistant classes of fiberboard shall be water-resistant to the extent that the end item will meet the require-ments of this specification (see 7.4). Paragraph 7.4 also appliesto the polyethylene linerboard bonds in the laminated facings.6.3 Triplewal

38、l and Triplewall/Fire Retardant CorrugatedFiberboard ClassesTriplewall corrugated fiberboard, domes-tic and domestic/fire retardant classes, non-weather-resistantand weather-resistant in both regular and fire-retardant classesshall conform to the requirements of Practice D5168.CONSTRUCTION6.4 Corrug

39、ated FiberboardCorrugated fiberboard shall bemade with two, three, or four facings for single, doublewall ortriplewall, respectively. Each facing shall be separated by andsecurely adhered to the corrugated medium.6.4.1 FlutesThe number of flutes per unit length offiberboard shall be as follows or as

40、 specified:Flutes/ft Flutes/m FluteHeight (in.)FluteHeight(mm)A-Flute 30 to 39 98 to 128 0.1575 to0.22104.00 to5.61B-Flute 45 to 53 147 to 174 0.0787 to0.11022.00 to2.80C-Flute 35 to 45 115 to 148 0.1300 to0.15753.30 to4.00E-Flute 70 to 98 229 to 321 0.0445 to0.05501.13 to1.406.5 Solid FiberboardSol

41、id fiberboard shall be constructedby laminating plies securely and continuously together.6.5.1 Domestic:6.5.1.1 Grades 125 and 175The fiberboard shall consistof not less than two plies of components.6.5.2 Grades 200 through 600The fiberboard shall consistof not less than three plies of components.6.

42、6 Scored SheetsThe scorelines on scored sheets shallshow no visual continuous surface break greater than specifiedin 7.6 when tested as specified in 9.3.6.7 Pads and Cut ShapesPads and cut shapes shall bemade in accordance with specified dimensions or drawings.6.7.1 Pads and cut shapes may be single

43、 sheets, or may bemade by laminating two or more sheets of specified types andclasses of material to the specified thickness.7. Physical Requirements7.1 Corrugated Fiberboard:7.1.1 Domestic and Domestic/Fire Retardant Classes, AllVarieties:7.1.1.1 FacingsThe facings shall conform to the require-ment

44、s in Table 1 when tested as specified in 9.1.2.7.1.1.2 Corrugating MediumThe corrugating medium forthe domestic/fire retardant classes of corrugated fiberboardshall weigh not less than 26 lb/1000 ft2127 g/m2, or asspecified, when tested in accordance with 9.1.2.7.1.1.3 End ItemDomestic and domestic/

45、fire retardantclasses of corrugated fiberboard, constructed as specified in6.4, shall conform to the requirements in Table 1 for burstingstrength or puncture resistance or edge crush (as specified)when tested as specified in 9.1.3, 9.1.5, or 9.1.8. (See compli-ance statement following Table 1 for Bu

46、rst and Edge Crush.)7.1.2 Weather-Resistant and Weather-Resistant/Fire Retar-dant ClassesThe components and end items conform to theapplicable basis weight and bursting strengths specified inTable 2 when tested as specified in 9.1.2, 9.1.5 and 9.2. Thecorrugating medium for the Weather-Resistant cla

47、sses andWeather-Resistant/Fire Retardant classes of corrugated fiber-board shall weigh not less than 30 lb/1000 ft2(146 g/m2), or asspecified, when tested in accordance with 9.1.2.7.1.3 Water and Water Vapor-Resistant, and Water andWater Vapor-Resistant/Fire Retardant Classes:7.1.3.1 ComponentsThe c

48、omponents shall conform to theapplicable requirements as specified in Table 2 and 6.1.1.1,when tested as specified in 9.1.2. The corrugating medium forthe Water and Water Vapor-Resistant, and Water and WaterVapor-Resistant/Fire Retardant classes of corrugated fiber-board shall weigh not less than 30

49、 lb/1000 ft2(146 g/m2), or asspecified, when tested in accordance with 9.1.2.7.2 Type SF (Solid Fiberboard):7.2.1 Class Domestic and Domestic/Fire Retardant:7.2.1.1 Facings and Filler PliesThe combined weights ofthe facings and filler plies shall conform to the requirements inTable 3 when tested as specified in 9.1.2.7.2.1.2 End ItemDomestic and domestic/fire retardantclasses of solid fiberboard constructed as specified in 6.5.1shall conform to the bursting strength requirements in Table 3,when tested as specified in 9.1.5.7