1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication BS ISO/IEC 29109-9:2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image dataBS IS
2、O/IEC 29109-9:2011 BRITISH STANDARD National foreword This British Standard is the UK implementation of ISO/IEC 29109-9:2011. The UK participation in its preparation was entrusted to Technical Committee IST/44, Biometrics. A list of organizations represented on this committee can be obtained on requ
3、est to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 68470 8 ICS 35.040 Compliance with a British Standard cannot confer immunity from legal obligations. This British
4、Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2011. Amendments issued since publication Date Text affectedBS ISO/IEC 29109-9:2011Reference number ISO/IEC 29109-9:2011(E) ISO/IEC 2011INTERNATIONAL STANDARD ISO/IEC 29109-9 First edition 2011-07-15
5、 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image data Technologies de linformation Mthodologie dessai de conformit pour les formats dinterchange de donnes biomtriques dfinis dans lISO/CEI 19794 Partie 9: Do
6、nnes dimages vasculaires BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) COPYRIGHT PROTECTED DOCUMENT ISO/IEC 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
7、and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland
8、ii ISO/IEC 2011 All rights reservedBS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All rights reserved iiiForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worldwide standardization.
9、National bodies that are members of ISO or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate in fields of mutual inte
10、rest. Other international organizations, governmental and non-governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with
11、 the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an International Standard requ
12、ires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights. ISO/IEC 29109-9 was pre
13、pared by Joint Technical Committee ISO/IEC JTC 1, Information technology, Subcommittee SC 37, Biometrics. ISO/IEC 29109 consists of the following parts, under the general title Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794: Par
14、t 1: Generalized conformance testing methodology Part 2: Finger minutiae data Part 4: Finger image data Part 5: Face image data Part 6: Iris image data Part 7: Signature/sign time series data Part 8: Finger pattern skeletal data Part 9: Vascular image data Part 10: Hand geometry silhouette data The
15、following parts are under preparation: Part 14: DNA data Finger pattern spectral data, signature/sign processed dynamic data and voice data will form the subjects of future parts. BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) iv ISO/IEC 2011 All rights reservedIntroduction ISO/IEC 19794-9:2007 spe
16、cifies a data record interchange format for exchange of human vascular image data among systems within a Common Biometric Exchange Formats Framework (CBEFF) data structure. The data stored in a vascular data record often contains the metadata storing the subject-specific and image- specific, as well
17、 as the technology being used. This part of ISO/IEC 29109 establishes tests for checking the correctness of the binary record. When vascular image data is transmitted among systems, it can be interfered with by noise due to the transmission line. The received data might be incorrect during the excha
18、nge process. Therefore, there is a need to conduct conformance tests of commercial products to determine whether the data conform to ISO/IEC 19794-9:2007 before using the data for other purposes. Vascular biometric technology is emerging or is under development by many research organizations. The va
19、scular image resources are also being used by many vendors, who have utilized the vascular technology as a recognition or verification method in their systems. Currently, however, there is no standardized method for conducting conformance tests of vascular image data that supports ISO/IEC 19794-9:20
20、07 during the exchange of vascular image data among systems. Application developers and implementers of different organizations can interpret ISO/IEC 19794-9:2007 in different manners. Therefore, a standardized conformance testing methodology is necessary for achieving interoperability among impleme
21、ntations. This part of ISO/IEC 29109 supports those applications that require use of vascular image data according to ISO/IEC 19794-9:2007. It defines a testing methodology to ensure conformance of a vendors application or service to ISO/IEC 19794-9:2007. Thus, it is intended to: establish elements
22、of the conformance testing methodology framework that are specific to the vascular image-based data record requirements of ISO/IEC 19794-9:2007 conformance testing; define requirements and guidelines for specifying conformance test suites and related test methods for measuring conformity of products
23、 and services to the vascular image data record requirements of ISO/IEC 19794-9:2007; and define testing and reporting procedures to be followed before, during, and after conformance testing. This part of ISO/IEC 29109 is applicable to the development and use of conformity test method specifications
24、, conformity test suites for ISO/IEC 19794-9:2007 records, and conformance testing programs for ISO/IEC 19794-9:2007 conformant products. It is intended primarily for use by testing organizations, but can be applied by developers and users of test method specifications and test method implementation
25、s. BS ISO/IEC 29109-9:2011 INTERNATIONAL STANDARD ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All rights reserved 1Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image data 1 Scope This part of ISO/IEC 29109 specifies
26、elements of conformance testing methodology, test assertions, and test procedures as applicable to ISO/IEC 19794-9. It specifies test assertions of the structure of the vascular image data format as specified in ISO/IEC 19794-9:2007 (Type A Level 1 as defined in ISO/IEC 29109-1), test assertions of
27、internal consistency by checking the types of values that can be contained within each field (Type A Level 2 as defined in ISO/IEC 29109-1). It does not specify a test of conformance of CBEFF structures required by ISO/IEC 19794-9:2007, a test of consistency with an input biometric data record (Leve
28、l 3), a test of other characteristics of biometric products or other types of testing of biometric products (e.g. acceptance, performance, robustness, security), a test of conformance of systems that do not produce ISO/IEC 19794-9:2007 records. 2 Conformance Biometric data interchange format conform
29、ance tests conform to this part of ISO/IEC 29109 if they satisfy all of the normative requirements related to Clause 6. Specifically, they shall use the test methodology specified in Clauses 6, 7 and 8 of ISO/IEC 29109-1:2009, and all Level 1 and Level 2 tests shall use the assertions defined in Tab
30、le 2 in this part of ISO/IEC 29109. Implementations of ISO/IEC 19794-9:2007 tested according to the specified methodology shall be able to claim conformance only to those Biometric Data Record (BDR) requirements specified in ISO/IEC 19794-9:2007 that are tested by the test methods established by thi
31、s methodology. Implementations of ISO/IEC 19794-9:2007 do not necessarily need to conform to all possible aspects of ISO/IEC 19794-9:2007, but only to those ISO/IEC 19794-9:2007 requirements that are claimed to be supported by the implementation in an Implementation Conformance Statement (ICS), fill
32、ed out in accordance with Clause 8 of ISO/IEC 29109-1:2009 and Table 1 in this part of ISO/IEC 29109. NOTE Level 3 and higher are not tested. BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) 2 ISO/IEC 2011 All rights reserved3 Normative references The following referenced documents are indispensable
33、for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO/IEC 19794-9:2007, Information technology Biometric data interchange formats Part 9: Vascular image
34、 data ISO/IEC 29109-1:2009, Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 1: Generalized conformance testing methodology 4 Terms and definitions For the purposes of this document, the terms and definitions given in ISO/IEC
35、 29109-1 apply. 5 Symbols and abbreviated terms For the purposes of this document, the symbols and abbreviations given in ISO/IEC 29109-1 apply. 6 Conformance testing methodology 6.1 General The testing methodology specified in Clauses 6, 7 and 8 of ISO/IEC 29109-1:2009 applies. The content of the t
36、ables below is based on the conformance testing methodology outlined in ISO/IEC 29109-1 and shall only be used in the context of that testing methodology. 6.2 Table of requirements in the base standard The normative requirements of ISO/IEC 19794-9:2007 are listed in Table 1. The supplier of the impl
37、ementation under test (IUT) can explain which optional components of ISO/IEC 19794-9:2007 are supported and the testing laboratory can note the results of the test. BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All rights reserved 3Table 1 Requirements of the base standard (ISO/IEC 19
38、794-9:2007) Requirement ID Reference in Base Standard Requirement Summary Level Status IUT Support Supported Range Test Result R-1 6.1 The quantities in all records and vascular biometric image elements (pixel data), if represented as multibyte quantities, are represented in big-endian format. 1 M N
39、/A R-2 6.1 The order for transmission shall also be the most significant byte first and the least significant byte last. Within a byte, the order of transmission shall be the most significant bit first and the least significant bit last. 3C O-1 N/A N/T R-3 6.2 The scan sequence shall be raster scan
40、order. 3C O-1 N/A N/T R-4 7.1 The spatial resolution of the captured image shall be represented in terms of pixels per centimetre. 3C O-1 N/A N/T R-5 7.2 The image shall have a dynamic range spanning at least 128 gray scale levels, allocating at least one byte (8 bits) per intensity value and provid
41、ing at least 7 bits of useful intensity information. 1 M N/A R-6 7.5 The captured image shall be an orthographic projection of the body area being imaged. 3C O-1 N/A N/T R-7 7.6.2 If lossless compression is used the image data shall be compressed in accordance with the JPEG-LS lossless compression a
42、lgorithm specified in ISO/IEC 14495 or the JPEG2000 compression algorithm specified in ISO/IEC 15444. 3C O-1 N/A N/T R-8 7.6.3 If lossy compression is used the image shall be compressed in accordance with the JPEG compression algorithm specified in ISO/IEC 10918 or the JPEG2000 compression algorithm
43、 specified in ISO/IEC 15444. 3C O-1 N/A N/T R-9 7.6.4 Images captured with more than three sensing channels shall be stored in accordance with the JPEG2000 compression algorithm as specified in ISO/IEC 15444. 3C O-1 N/A N/T R-10 7.7 The location of human body used for imaging shall be specified in t
44、he format. 1 M N/A R-11 7.7 The direction (left/right) of hand and/or finger index (thumb, index, middle, ring, and little) shall be specified. 1 M N/A R-12 8.2.1 The format identifier for the vascular biometric image standard record shall consist of the three ASCII characters “VIR“ followed by a nu
45、ll character (0x00). 1 M N/A R-13 8.2.2 The number for the version of this standard used for constructing the image record shall be placed in four bytes. This version number shall consist of three ASCII numerals followed by a zero byte as a NULL string terminator. The first and second characters wil
46、l represent the major version number, while the third character will represent the minor revision number. The current version number shall be 010 indicating the version 1 with no revision. 1 M N/A R-14 8.2.3 The combined length in bytes for the entire record shall be recorded in these four bytes. 1
47、M R-15 8.2.3 This count shall be total length of record block including record header and image headers. 2 M R-16 8.2.4 The capture device ID shall be recorded in two bytes. A value of all zeros shall be acceptable and will indicate that the device ID is unreported. The vendor determines the value f
48、or this field. Application developers may obtain the values for these codes from the respective vendors. 1 M BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) 4 ISO/IEC 2011 All rights reservedR-17 8.2.5 The number of vascular images included in the data block shall be recorded in two bytes. 2 M R-18
49、8.2.5 It is required that all images in a single vascular image data block be from the same imaging device. If two images are captured by two different devices with different capture device IDs, they shall be stored in separate data blocks, not in the same block. 3C O-1 N/A N/T R-19 8.3.2 This four-byte field shall specify the total length of the image block including the image header and data. 1 M R-20 8.3.2 This four-byte field shall specify the total length of the image bl