BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf

上传人:eveningprove235 文档编号:397123 上传时间:2018-10-18 格式:PDF 页数:12 大小:511KB
下载 相关 举报
BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf_第1页
第1页 / 共12页
BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf_第2页
第2页 / 共12页
BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf_第3页
第3页 / 共12页
BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf_第4页
第4页 / 共12页
BS PAS 57-2003 Cellar cooling equipment - Procedure for determining performance and calculating energy efficiency《地下室冷却设备 测定性能和计算能效的规程》.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、PUBLICLY AVAILABLE SPECIFICATION PAS 57:2003 Cellar cooling equipment Procedure for determining performance and calculating energy efficiency ICS 27.200; 97.130.20 PAS 57:2003 This Publicly Available Specification comes into effect on 20 March 2003 BSI 20 March 2003 ISBN 0 580 41407 8 Amendments iss

2、ued since publication Amd. No. Date CommentsPAS 57:2003 BSI 20 March 2003 i Contents Page Committees responsible Inside front cover Foreword ii Introduction 1 1S c o p e 1 2 Normative references 1 3T e r m s a n d D e f i n i t i o n s 1 4 Principle 2 5 Preparation 2 6 Measurement procedure 4 7 Calc

3、ulation of coefficient of performance 5 8 Evaluation report 6PAS 57:2003 ii BSI 20 March 2003 Foreword This Publicly Available Specification, PAS 57, was sponsored by the DTI Construction Sector Unit and DEFRAs Market Transformation Programme and developed through the British Standards Institution.

4、Acknowledgement is given to the following organizations that were consulted in the development of this Publicly Available Specification. Future Energy Solutions AEA Technology BSI Product Services Cool Concerns Hubbard Refrigeration Searle Manufacturing Eaton-Williams IMI Air Conditioning Thermofros

5、t Cryo NRS-Wholesale Federation of Environmental Trade Associations Six Continents Daniel Thwaites Brewery This Publicly Available Specification has been prepared and published by BSI, which retains its ownership and copyright. BSI reserves the right to withdraw or amend this PAS on receipt of autho

6、ritative advice that it is appropriate to do so. This PAS will be reviewed at intervals not exceeding two years, and any amendments arising from the review will be published as an amended PAS and publicized in Update Standards. This publication does not purport to include all the necessary provision

7、s of a contract. Users are responsible for its correct application. This Publicly Available Specification (PAS) is not to be regarded as a British Standard. It will be withdrawn upon publication of its content in, or as, a British Standard. Compliance with a Publicly Available Specification does not

8、 in itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 6, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.PAS 5

9、7:2003 BSI 20 March 2003 1 Introduction This Publicly Available Specification was developed to provide manufacturers and suppliers of cellar cooling equipment with procedures and defined conditions for measuring the performance of their products and calculating the energy efficiency, expressed as a

10、coefficient of performance. It is expected that the use of coefficient of performance values for cellar cooling equipment will provide purchasers of such equipment with the means for comparing product energy efficiency information. 1 Scope This Publicly Available Specification (PAS) specifies proced

11、ures for determining the performance and energy efficiency of cellar cooling equipment with a capacity between 2 kW and 12 kW, at a standard rating condition of 10 C air onto the evaporator and 32 C air onto the condenser, using air cooled condensers categorized as either: a) a packaged system, comp

12、rising all components mounted on one base for “through the wall” installation; or b) a split system, with the equipment supplied in two parts (evaporator and condensing unit) to be connected on site; or c) a remote system, with equipment supplied in three parts (evaporator, compressor/receiver unit

13、and condenser) to be connected on site. This PAS is aimed at suitably qualified and experienced personnel in the refrigeration industry. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited appl

14、ies. For undated references, the latest edition of the referenced document (including any amendments) applies. BS EN 328, Heat exchangers Test procedures for establishing the performance of forced convection unit air coolers for refrigeration. 3 Terms and Definitions For the purposes of this Publicl

15、y Available Specification, the following terms and definitions apply. 3.1 cellar cooling equipment refrigeration system designed to maintain an indoor environment at a condition suitable for the storage of chilled beverages, typically 10 C to 12 C 3.2 refrigerant working fluid in a refrigerating sys

16、tem absorbing heat at low pressure/temperature by evaporation and rejecting it at a higher pressure/temperature by condensation 3.3 liquid working fluid remaining liquid during the absorption of heat 3.4 cooling capacity total heat (kW) removed by the cellar cooling equipment from test room B 3.5 ev

17、aporator pressure absolute pressure of the refrigerant at the evaporator outlet 3.6 compressor discharge pressure absolute pressure of the refrigerant at the compressor discharge portPAS 57:2003 2 BSI 20 March 2003 3.7 expansion device device used to control the flow of refrigerant in the evaporator

18、 and reduce the refrigerant pressure 3.8 system energy consumption total electrical energy consumption of the cellar cooling equipment as measured during the system efficiency test 3.9 liquid receiver pressure vessel permanently installed in the high pressure side of a refrigeration system to provid

19、e a reserve of liquid refrigerant and for the storage of the refrigerant charge during service 3.10 filter drier device used to remove water or water vapour from refrigerant 3.11 compressor mechanically operated component for compressing a refrigerant vapour 3.12 heat load electrical heating applian

20、ce resistance heater(s), with adjustable output, used to balance the heat extraction rate of the cooling unit 3.13 thermal mass pre-cooled liquid or solid mass used to dampen temperature changes in the test room 3.14 thermostat phial temperature sensing part of the thermostat 4 Principle The energy

21、efficiency of cellar cooling equipment is evaluated by measuring its cooling capacity and energy consumption at specified conditions and expressing the results as a ratio. 5 Preparation 5.1 General The cellar cooling system under evaluation shall be supplied complete. All components supplied as part

22、 of the cellar cooling equipment system shall be included in the evaluation and used in accordance with the manufacturers instructions. The cellar cooling equipment shall be evaluated in the “as-sold” condition, i.e. installed and commissioned as recommended by the manufacturer. 5.2 Test rooms 5.2.1

23、 Test room A The condensing unit, consisting of the compressor, condenser, liquid receiver (where fitted), filter drier, or compressor/receiver set plus air cooled condenser or outdoor part of the packaged system shall be located in test room A. The temperature and humidity is controlled in test roo

24、m A, which shall have sufficient volume for unrestricted airflow through the condenser.PAS 57:2003 BSI 20 March 2003 3 5.2.2 Test room B (calorimeter room) The evaporator and expansion valve (where fitted to the evaporator) shall be located in test room B (the cellar). Test room B shall be an insula

25、ted chamber with a heat load to simulate cellar conditions. Test room B shall be of a size such that: a) no obstacle is positioned within a distance of of the evaporator outlet; b) no obstacle is positioned within a distance of parallel to the sides of the evaporator; c) the volume in m 3is between

26、1/30 and 1/600 of the air flow rate in m 3 /h produced by the evaporator, where A and B are the air inlet dimensions of the evaporator. Test room B shall have a thermal mass such that during the system efficiency test, the room temperature increases at a rate less than 1 C in 5 min when the cellar c

27、ooling equipment is turned off. 5.3 Cellar cooling equipment installation 5.3.1 General The distance of the air on the face of the condenser from the test room wall shall be in accordance with the original equipment manufacturers specifications for that condenser or condensing unit. The distance of

28、the air on the face of the evaporator from the test room wall shall be in accordance with the original equipment manufacturers specification for that evaporator. Following assembly of the split and remote equipment (see 5.3.2 and 5.3.3), the system shall be evacuated to a vacuum of better than 2 mm

29、Hg. Abs. The system shall then be charged with the type and amount of refrigerant as specified by the manufacturer. All controls shall be set as specified by the manufacturer. 5.3.2 Split systems The following shall apply for split systems. a) The liquid and suction pipes shall be at least 5 m long,

30、 with excess pipe looped and not bent. b) Excess pipe shall be positioned within test room A. c) The pipe size and insulation type, thickness and location shall be in accordance with the manufacturers specifications. 5.3.3 Remote systems The following shall apply to remote systems. a) The pipe betwe

31、en the compressor and condenser shall be at least 5 m long. b) The pipe between the condenser and receiver shall be at least 5 m long. c) The pipe between the receiver and evaporator shall be at least 5 m long. d) The pipe between the evaporator and compressor shall be at least 5 m long. e) All exce

32、ss pipe shall be looped and not bent. f) Excess pipe shall be positioned within test room A. g) The pipe size and insulation type, thickness and location shall be in accordance with the manufacturers specifications. h) The expansion device shall be positioned and adjusted in accordance with the manu

33、facturers specifications. 1.5 AB 0.75 AB PAS 57:2003 4 BSI 20 March 2003 6 Measurement procedure 6.1 General The following conditions shall be applied: a) relative humidity of test room B shall be held at (80 5) %; b) single phase equipment shall be tested at (230 5) V and (50 0.5 ) Hz; c) three pha

34、se equipment shall be tested at (400 8) V and (50 0.5) Hz. 6.2 Cooling capacity measurement Measure the cooling capacity of the system (kW) at the following condition: air onto the condenser at (32 0.5) C; test room B temperature at (10 0.5) C; and cellar unit operating continuously (not cycling on

35、thermostat). Using the calorimeter room electrical heat balance method in accordance with BS EN 328, measure the cooling capacity at steady state conditions, which shall be achieved at least 30 min prior to the evaluation commencing, and maintained for 1 h. Steady state conditions shall be considere

36、d to be when the air onto the evaporator and condenser is maintained at the specified condition. The temperature in test room B for the cooling capacity test shall be (10 0.5) C, with the average temperature during the 1 h period being between 9.8 C and 10.2 C, controlled by the test room controller

37、. 6.3 System energy consumption measurement Measure the system energy consumption (kWh) at the following condition: cooling capacity as measured during 6.2; air onto the condenser at (20 0.5) C; test room B temperature at (10 0.5) C; and cellar unit cycling on its thermostat. Measure the system ener

38、gy consumption at steady state conditions, which shall be achieved at least 30 min prior to the test commencing, and be maintained for the duration of the test, which shall be at least 2 h. NOTE System energy consumption measured is in kWh, however, the system energy consumption should be calculated

39、 in kW. Calculate the system energy consumption (kW) as follows: Steady state conditions shall be considered to be when: a) air onto the evaporator has reached 10 C; b) air onto the evaporator is maintained within the band 9.5 C to 10.5 C; c) air onto the condenser is maintained within 19.5 C and 20

40、.5 C. The temperature in test room B for the system efficiency test shall be (10 0.5) C, with the average temperature during the test period being between 9.8 C and 10.2 C, controlled by the system controller. system energy consumption (kW) system energy consumption measured (kWh) test duration (h)

41、- =PAS 57:2003 BSI 20 March 2003 5 6.4 Conditions to be recorded During the procedures set out in 6.2 and 6.3, the following conditions shall be recorded. 6.4.1 Temperature ( C), accuracy 0.2 C of the: a) air onto the condenser at 4 locations across condenser air on the face; b) air onto the evapora

42、tor at 4 locations across evaporator air on the face. 6.4.2 Temperature ( C), accuracy 0.5 C of the: a) compressor suction (pipe surface as close to the compressor as possible); b) compressor discharge (pipe surface as close to the compressor as possible); c) condenser inlet (pipe surface); d) conde

43、nser outlet (pipe surface); e) receiver inlet (pipe surface); f) receiver outlet (pipe surface); g) filter drier outlet (pipe surface); h) expansion device inlet (pipe surface); i) expansion device outlet (pipe surface); j) evaporator outlet (pipe surface as close to the thermostatic expansion valve

44、 (TEV) phial, where fitted, as possible); k) test room B (adjacent to the thermostat phial, where fitted); l) air off the evaporator at 4 locations across air off the face. 6.4.3 Pressure (bar abs), accuracy equivalent to 0.5 C of the: a) evaporator pressure, after distributor, if fitted; b) compres

45、sor discharge pressure. 6.4.4 Electrical energy (kW), accuracy 1 % of the: a) compressor(s); b) evaporator fan(s); c) defrost heater(s), if fitted; d) condenser fan(s); e) heat input to test room B. 6.4.5 Heat loss/gain through the structure of test room B (kW) in accordance with BS EN 328, accuracy

46、 within 1 % of measured capacity. 6.4.6 The voltage (V) of the electrical supply, accuracy 2 %. 6.4.7 The frequency (Hz) of the electrical supply, 1 %. 7 Calculation of coefficient of performance The coefficient of performance (COP) shall be calculated using the formula: COP = system cooling capacit

47、y (kW), determined in accordance with 6.2 system energy consumption (kW), determined in accordance with 6.3PAS 57:2003 6 BSI 20 March 2003 8 Evaluation report The following information shall be reported: a) measurement procedure; b) cellar cooling equipment manufacturer; c) cellar cooling equipment

48、category, i.e. packaged system, split system or remote system; d) model designation; e) refrigerant; f) electrical supply voltage (V) and frequency (Hz); g) cooling capacity (kW) derived during the capacity measurement; h) cooling capacity (kW) derived during the system energy consumption measurement; i) total energy consumption (kWh) of the compressor, evaporator and condenser fan motors and defrost heaters (where fitted) derived during the system energy consumption measurement; j) duration of the system energy consumption measurement (h); k) heat flow

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1