BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf

上传人:boatfragile160 文档编号:397521 上传时间:2018-10-18 格式:PDF 页数:38 大小:3.99MB
下载 相关 举报
BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf_第1页
第1页 / 共38页
BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf_第2页
第2页 / 共38页
BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf_第3页
第3页 / 共38页
BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf_第4页
第4页 / 共38页
BS PD CEN TS 16868-2015 Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method《环境空气 过敏网络用空气中花粉粒和真菌孢子的采集.pdf_第5页
第5页 / 共38页
亲,该文档总共38页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards Publication Ambient air Sampling and analysis of airborne pollen grains and fungal spores for allergy networks Volumetric Hirst method PD CEN/TS 16868:2015National foreword This Published Document is the UK implementation of CEN/TS 16868:2015. The UK participation in its preparation wa

2、s entrusted by Technical Committee EH/2, Air quality, to Subcommittee EH/2/3, Ambient atmospheres. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are res

3、ponsible for its correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015 ISBN 978 0 580 88245 6 ICS 13.040.20 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of th

4、e Standards Policy and Strategy Committee on 30 November 2015. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD CEN/TS 16868:2015 TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16868 November 2015 ICS 13.040.20 English Version Am

5、bient air - Sampling and analysis of airborne pollen grains and fungal spores for allergy networks - Volumetric Hirst method Air ambiant - chantillonnage et analyse des grains de pollen et des spores fongiques ariens pour les rseaux arobiologiques - Mthode volumtrique de Hirst Auenluft - Probenahme

6、und Analyse luftgetragener Pollen und Pilzsporen fr Allergienetzwerke - Volumetrische Hirst-Methode This Technical Specification (CEN/TS) was approved by CEN on 15 September 2015 for provisional application. The period of validity of this CEN/TS is limited initially to three years. After two years t

7、he members of CEN will be requested to submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard. CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available promptly at nationa

8、l level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is reached. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croat

9、ia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and Un

10、ited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. C

11、EN/TS 16868:2015 E PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 2 Contents Page European foreword . 3 Introduction 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 5 4 Principle . 8 5 Sampling . 8 5.1 Equipment . 8 5.1.1 Apparatus . 8 5.1.2 Scrolling speed of support 11 5.1.3 Impaction su

12、pport . 11 5.1.4 Wind vane and rain shield 13 5.1.5 Complete sampling system . 14 5.2 Operating procedure 14 5.2.1 Preparation of the coating medium 12 . 14 5.2.2 Support preparation . 15 5.2.3 Changing of the drum 16 6 Analysis 16 6.1 Equipment required 16 6.2 Operating procedure 17 6.2.1 Support 1

13、7 6.2.2 Mounting medium 17 6.3 Methodology for counting . 18 6.3.1 Glass slide preparation for microscopy analysis for drum tape 13 14 18 6.3.2 Optical microscopy 14 16 . 20 6.3.3 Identification 15 16 . 20 6.3.4 Counting method 20 6.3.5 Data recording . 20 6.3.6 Conversion factor . 21 7 Performance

14、characteristics 10 11 17 18 19 . 22 7.1 General . 22 7.2 Performance requirements 22 7.2.1 Repeatability 22 7.3 Performance recommendations 18 19 22 7.3.1 Reproducibility and accuracy 22 7.3.2 Sensitivity and specificity 22 Annex A (informative) Hirst type volumetric trap 24 Annex B (informative) Pi

15、ctures of impaction support. 25 Annex C (informative) Safety data sheet . 27 Annex D (informative) Key of determination . 28 Bibliography . 32 PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 3 European foreword This document (CEN/TS 16868:2015) has been prepared by Technical Committee CEN/TC 264 “Air qual

16、ity”, the secretariat of which is held by DIN. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal R

17、egulations, the national standards organizations of the following countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ir

18、eland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 4 Introduction Biological particles (pollen and fungal spores) are present in t

19、he air, causing health impacts at various levels. In Europe, nearly 18 % to 20 % of people suffer from pollinosis due to pollen and/or fungal spores. Pollen grains and fungal spores are considered in some Member States as an air pollutant as well as particles suspended in the air (PM 10, 2,5). In Eu

20、rope, European Aerobiology Society (EAS) in coordination with International Association for Aerobiology (IAA) manage problems of sampling, analysis, quality control, development and information. For the sampling and analysis of biological particles different methodology and operating procedures are

21、used. Sampling equipment is diversified (see Annex A). Analysis is based on optical light microscopy for identification and counting pollen grains and fungal spores. Elements and reagents used during sampling and analysis have very specific properties and require to be handled carefully. Given the c

22、lose relationship between aerobiology and other sciences, one of the main aims is that information on airborne biological-particle counts should be of use in a wide range of disciplines and fields of application, including aerobiology, biodiversity, agriculture, forestry, phytopathology, meteorology

23、, climatology, forensic science, bioterrorism, and health (sensitization and allergy). PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 5 1 Scope This European Standard specifies the procedure to sample continuously and analyse the concentration of airborne pollen grains and fungal spores in ambient air us

24、ing the volumetric Hirst type sampler 1 2 3 (see Annex A). This European Standard describes both the sampling and the analysis procedures for the purpose of allergy networks. For the other tasks mentioned in the introduction, other specifications may be required. 2 Normative references Not applicabl

25、e. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 accuracy closeness of agreement between a measured quantity value and a true quantity value of a measurement 3.2 bench long work table in a workshop or laboratory 3.3 clockwork mechanism with

26、 a spring and toothed gearwheels, used to drive a mechanical clock, toy, or other device 3.4 combined standard measurement uncertainty obtained using the individual standard measurement uncertainties associated with the input quantities in a measurement model 3.5 defatted surface conditions after cl

27、earing with a fat removing substance 3.6 drum cylindrical device for the mounting of a sticky tape 3.7 exine outer layer of the wall of a spore or pollen grain, also called an exosporium 3.8 eyepiece lens or combination of lenses in an optical instrument through which the eye views the image formed

28、by the objective lens or lenses; ocular PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 6 3.9 flow meter instrument for measuring the flow rate of a fluid in a pipe 3.10 flow rate amount of fluid (e.g. air) that flows in a given time 3.11 fungal spore reproductive unit capable of giving rise to a new indi

29、vidual with or without sexual fusion 3.12 hood metal cover or canopy for a stove, ventilator, etc 3.13 impaction sampling of airborne particles by inertial separation on any surface (e.g. of an adhesive) 3.14 magnetic stirrer object or mechanical device used for stirring something 3.15 magnification

30、 magnifying power of an instrument, e.g. this microscope should give a magnification of about x 100 3.16 microscope optical instrument having a magnifying lens or a combination of lenses for inspecting objects too small to be seen or too small to be seen distinctly and in detail by the unaided eye 3

31、.17 objectives optics (in a telescope, microscope, camera, or other optical system), the lens or combination of lenses, that first receive the rays from the object and form the image in the focal plane of the eyepiece, as in a microscope, or on a plate or screen as in a camera Note 1 to entry: Also

32、called object glass, object lens, objective lens. 3.18 orifice opening or aperture, as of a tube or pipe; a mouthpiece with a slotlike opening on the side of the trap 3.19 particle minute portion of matter PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 7 3.20 pollen male gametophyte of flowering plants,

33、consisting of microscopic grain discharged from the anthers (Angiosperms) or from a male cone (Gymnosperms) Note 1 to entry: Each grain contains two male gametes (only one can fertilize the female ovule). Note 2 to entry: Pollen are transported by wind, water, animals (e.g. insects). 3.21 precision

34、closeness of agreement between indications or measured quantity values obtained by replicate measurements on the same or similar objects under specified conditions 3.22 repeatability condition of measurement, out of a set of conditions that includes the same measurement procedure, same operators, sa

35、me measuring system, same operating conditions and same location, and replicate measurements on the same or similar objects over a short period of time 3.23 reproducibility condition of measurement, out of a set of conditions that includes different locations, operators, measuring systems, and repli

36、cate measurements on the same or similar objects 3.24 sensitivity in aerobiology, measurement of the proportion of search particle which is correctly identified 3.25 slide rectangular piece of glass on which an object is mounted or placed for examination under a microscope 3.26 specificity in aerobi

37、ology, measurement of the proportion of non-searched particles which are correctly identified as different from the searched particles 3.27 standard measurement uncertainty measurement uncertainty expressed as a standard deviation 3.28 suction production of a negative pressure by the removal of air

38、to force fluid into a vacant space 3.29 taxon taxonomic group of any rank, such as a species, family or class 3.30 trap container or device used to collect something PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 8 3.31 vacuum space from which the air has been completely or partly removed 3.32 vacuum pum

39、p pump or device by which a partial vacuum can be produced 3.33 wind vane mechanical device attached to an elevated structure; rotates freely depending on the direction of the wind 4 Principle Ambient air is sampled by a volumetric suction system and directed towards a suitably coated sampling surfa

40、ce through a specific orifice oriented towards the wind; the particles contained in the sampled air are deposited by impaction on a continuously moving adhesive acceptor surface. The sampling surface is then examined with an optical microscope in order to identify and count the allergy relevant part

41、icles per area (deposition rates). Using this method allows to count particles and subsequently calculate concentrations as a daily mean or a 2-hour mean. The low-volume sampler (10 l/min) allows a continuous sampling for up to seven days 4 5 6. 5 Sampling 5.1 Equipment 5.1.1 Apparatus 5.1.1.1 Motor

42、ised suction pump The motorised suction pump shall work 24 hours a day and continuously throughout the year always at the same flow rate. The power supply may be either mains or battery driven (solar panels). The electric motor shall be capable of continuous operation. The suction system, for instan

43、ce, a vacuum pump, shall have a regular and continuous flow rate. The flow rate of suction may be adjusted by a flow control valve. The flow rate shall be 10 l/min (1 l/min). The flow rate shall be checked at every change of the impaction support with an adapted flow meter (i.e. the flow meter suppl

44、ied by the same supplier of the sampler). The flow meter shall be checked annually or less depending on the historical experience. Sampling shall always be continuous and stable. The support shall scroll regularly in front of the back outlet of the orifice; its geometry and the scrolling speed depen

45、d on the duration of sampling period requested. Example for the sampling area: a support of 48 mm (tape) with a speed of 2 mm/h: sampling period = one day; a flexible support of 336 mm with a speed of 2 mm/h: sampling period = seven days. The scrolling speed may be adjusted to other sampling period

46、durations. The trap can work with two different impaction supports: a drum (see Figure 1a) covered with a coated transparent tape or a glass slide (see Figure 1b) coated. PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 9 Key 1 lid 2 start reference pointer 3 lock nut 4 orifice start position 5 trapping su

47、rface Figure 1a The Hirst volumetric trap showing 7-day lid assembly with drum 5, modified PD CEN/TS 16868:2015CEN/TS 16868:2015 (E) 10 Key 1 lid 3 lock nut 6 trapping surface on slide Figure 1b The Hirst volumetric trap showing 24-h lid assembly with slide 5, modified 5.1.1.2 Specific orifice The o

48、rifice shall have the following dimensions (with associated tolerances): rectangular opening: 14 mm (0,1 mm) 2 mm (0,1 mm) depth of the orifice: 19 mm distance from the inside orifice to the drum without the tape: 0,70 mm (0,1 m) The depth allows the non-turbulence of laminar flow and directs the mi

49、xture of air and particles towards the coated support. In consequence, an efficient particle impaction for pollen grains and fungal spores, induced by the laminar flow, is ensured. The outlet of the orifice shall be 0,70 mm (0,1 mm) of the coated support (see Figure 2 distance A-B). The distance allows efficient particle impaction for pollen grains and fungal spores. It shall be controlled with a ruler 7 8 9. The orifice should be directed into the air-stream using a wind vane. PD CEN/TS 16868:

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1