BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf

上传人:postpastor181 文档编号:397587 上传时间:2018-10-18 格式:PDF 页数:24 大小:1,022KB
下载 相关 举报
BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf_第1页
第1页 / 共24页
BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf_第2页
第2页 / 共24页
BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf_第3页
第3页 / 共24页
BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf_第4页
第4页 / 共24页
BS PD CLC TR 50656-2016 SPD application in conjunction with Class II equipment《结合II类设备的SPD应用》.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards Publication SPD application in conjunction with Class II equipment PD CLC/TR 50656:2016National foreword This Published Document is the UK implementation of CLC/TR 50656:2016. The UK participation in its preparation was entrusted by Technical Committee PEL/37, Surge Arresters - High Vo

2、ltage, to Subcommittee PEL/37/1, Surge Arresters - Low Voltage. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct applicatio

3、n. The British Standards Institution 2016. Published by BSI Standards Limited 2016 ISBN 978 0 580 91543 7 ICS 29.120.50 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Com

4、mittee on 31 March 2016. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD CLC/TR 50656:2016 TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50656 March 2016 ICS 29.120.50 English Version SPD application in conjunction with Class II equipment Paraf

5、oudres destins tre utiliss avec des quipements classe II SPD Anwendungen in Verbindung mit Schutzklasse II This Technical Report was approved by CENELEC on 2015-12-14. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Den

6、mark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European

7、Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for

8、 CENELEC Members. Ref. No. CLC/TR 50656:2016 E PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 2 Contents Page European foreword 3 Introduction 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions 5 3.1 SPD assembly one SPD or a set of SPDs, in both case including all SPD disconnectors require

9、d by the SPD manufacturer, providing the required overvoltage protection for a type of system earthing . 5 3.2 extraneous conductive part conductive part not forming part of the electrical installation and liable to introduce an electric potential, generally the electric potential of a local earth 5

10、 3.3 functional earth . 5 3.4 class II SPD 6 3.5 protective earthing 6 3.6 protective conductor 6 3.7 protective earthing conductor . 6 4 SPDs connected to PE for the protection of Class II equipments . 6 4.1 General . 6 4.2 TN System . 8 4.3 TT System 9 4.4 IT System . 10 4.5 Example of lighting po

11、le surge protection connected to PE . 11 5 SPDs not connected to PE for the protection of Class II equipments 11 5.1 General . 11 5.2 Examples . 12 6 Additional requirements for SPDs to comply with equipment class II design rules (Double or reinforced insulation) 14 6.1 General . 14 6.2 Requirements

12、 for basic protection (protection against direct contact) and fault protection (protection against indirect contact) 15 6.2.1 Class II SPD . 15 6.2.2 Enclosures . 16 Annex A (normative) Test to establish whether a conductive part may cause an electric shock 18 PD CLC/TR 50656:2016CLC/TR 50656:2016 (

13、E) 3 European foreword This document (CLC/TR 50656:2016) has been prepared by CLC/TC 37A “Low voltage surge protective devices”. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for

14、identifying any or all such patent rights. PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 4 Introduction Based on questions and requests from the field it was felt necessary to provide some guidance and instructions how and in which applications currently available SPDs according to EN 61643-11 can be co

15、rrectly and safely applied in conjunction with class II equipment and in installations, where the protective measure double or reinforced insulation is applied (see HD 60364-4-41 and EN 61140). In general current SPDs according EN 61643-11 are designed to properly protect wherever: basic insulation

16、is required e.g. between active parts and the protective equipotential bonding system (PE) (the SPD bridges basic insulation in such applications); basic or functional insulation is required e.g. between active parts of different potential (the SPD bridges basic or functional insulation in such appl

17、ications). The requirements currently contained in EN 61643-11 do not cover requirements for SPD applications, where the SPD bridges double or reinforced insulation, like e.g. between primary and secondary side of an isolating transformer (protective separation) or between active parts and touchable

18、 conductive surfaces of class II equipment. There are attempts to develop requirements for such SPDs, but for the time being there is no defined solution. This document refers to HD 60364-4-41 for topics related to installation rules and to EN 62368-1 for some equipments related topics. This documen

19、t specially addresses installation issues related to street lighting. PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 5 1 Scope In addition to CLC/TS 61643-12, this Technical Report describes the principle of erecting SPDs to be connected to 50 Hz a.c. power circuits, rated up to 1 000 V r.m.s. in conjunc

20、tion with Class II equipments. In addition to EN 61643-11, this Technical Report gives specific guidance for SPDs intended to be installed in class II equipments. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable fo

21、r its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50539-11:2013, Low-voltage surge protective devices - Surge protective devices for specific application including d.c.

22、 - Part 11: Requirements and tests for SPDs in photovoltaic applications EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529) 1EN 60664-1, Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests (IEC 60664-1) 2EN 60950-1, In

23、formation technology equipment Safety Part 1: General requirements (IEC 60950-1) 3EN 61643-11:2012, Low-voltage surge protective devices Part 11: Surge protective devices connected to low-voltage power systems Requirements and test methods (IEC 61643-11:2011) 4EN 62368-1:2014, Audio/video, informati

24、on and communication technology equipment Part 1: Safety requirements (IEC 62368-1:2014, modified) 5HD 60364 (all parts), Low-voltage electrical installations (IEC 60364, all parts) 63 Terms and definitions For the purposes of this document, the following terms and definitions apply. 1http:/www.cene

25、lec.eu/dyn/www/f?p=104:110:695920932773601:FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:125802 5,43747,25 2http:/www.cenelec.eu/dyn/www/f?p=104:110:379108178804401:FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:125849 7,50513,25 3http:/www.cenelec.eu/dyn/www/f?p=104:110:1457986987015001:FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID

26、:12571 89,53711,25 4http:/www.cenelec.eu/dyn/www/f?p=104:110:592568428155801:FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:125861 7,43963,25 5http:/www.cenelec.eu/dyn/www/f?p=104:110:785888442943801:FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:125718 9,60205,25 6http:/www.cenelec.eu/dyn/www/f?p=104:110:437816408653901:F

27、SP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:125716 3,57623,25 PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 6 3.1 SPD assembly one SPD or a set of SPDs, in both case including all SPD disconnectors required by the SPD manufacturer, providing the required overvoltage protection for a type of system earthing SOURCE

28、: IEC 60364-5-53, modified 3.2 extraneous conductive part conductive part not forming part of the electrical installation and liable to introduce an electric potential, generally the electric potential of a local earth SOURCE: IEC 60050-826 3.3 functional earth earthing a point or points in a system

29、 or in an installation or in equipment, for purposes other than electrical safety SOURCE: EN 62368-1:2014 53.4 class II SPD SPDs in which protection against electric shock does not rely on basic insulation only, but in which additional safety precautions such as double insulation or reinforced insul

30、ation are provided, there being no provision for protective earthing or reliance upon installation conditions Note 1 to entry: Such a SPD may have a substantially continuous enclosure of metal, insulated from live parts by insulation at least equivalent to double or reinforced insulation. Such a SPD

31、 is called a metal-encased class II SPD. Note 2 to entry: The enclosure of an insulation-encased class II SPD may form a part or the whole of the supplementary insulation or the reinforced insulation. Note 3 to entry: If a SPD with double insulation and/or reinforced insulation throughout has a prot

32、ective earthing, it is class I construction, Note 4 to entry: Class II SPD may have parts in which protection against electric shock relies on operation at safety extra-low voltage (SELV). Note 5 to entry: Such SPDs should be marked with the symbol . SOURCE: EN 60598-1:2015, modified 73.5 protective

33、 earthing earthing a point or points in a system or in an installation or in equipment for purposes of electrical safety SOURCE: EN 62368-1:2014, modified 53.6 protective conductor conductor provided for the purposes of safety (for example, protection against electric shock) 7http:/www.cenelec.eu/dy

34、n/www/f?p=104:110:1827578021514001:FSP_ORG_ID,FSP_PROJECT,FSP_LA NG_ID:1257233,50934,25 PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 7 Note 1 to entry: A protective conductor is either a protective earthing conductor or a protective bonding conductor. SOURCE: EN 62368-1:2014 53.7 protective earthing co

35、nductor protective conductor connecting a main protective earthing terminal in the equipment to an earth point in the building installation for protective earthing SOURCE: EN 62368-1:2014 54 SPDs connected to PE for the protection of Class II equipments 4.1 General In the four following examples, a

36、Class II equipment is integrated into a conductive metallic housing that is connected to PE (i.e. Class I equipment), whereby the protective measures according to HD 60364-4- 41:2007, Clause 411 are effective. The three first following examples describe the recommended location and protection measur

37、es against electric shock for SPD assembly used to protect Class II equipment connected to TN, TT and IT power systems. The forth example is dedicated to special application: metallic street lighting pole. The SPD used in such installation shall comply with EN 61643-11. The installation rules descri

38、bed in HD 60364-5-534 shall be applied, and in addition the rules related to surge protection described in CLC/TS 61643-12 are applicable. A dedicated conductor between the PE and SPD fulfilling the HD 60364-4-41:2007, 411.3.1.1 measures against electric shock is required. Alternatively, the metal c

39、onductive housing itself enclosing the SPD and the Class II equipment, may be used as protective conductors if they simultaneously satisfy the following three requirements: a) their electrical continuity should be ensured by construction or by suitable connection so as to ensure protection against m

40、echanical, chemical or electrochemical deterioration; b) they comply with the requirement of minimum cross section area according to HD 60364-5-54:2011, 543.1 c) they should permit the connection of other protective conductors at every predetermined tap off point. Additional requirements are given i

41、n HD 60364-5-54:2011, 543.2 and 543.3. Nevertheless, an additional functional bounding connection as short as possible can be used to ensure a better surge protection provided by the SPD. In the following pictures, the overcurrent protection is only shown if it is required as protective measure agai

42、nst electrical shock. PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 8 4.2 TN System Key T transformer P protection measures against electric shock (i.e. Fuse or Breaker). Automatic disconnection according to HD 60364-4- 41:2007, 411.4 1 class II equipment 2 conductive housing 3 direct connection to PE F

43、igure 1 Example of SPDs connected to PE protecting Class II equipments in TN System L N PE P 3 1 2 T PEN SPD Assembly PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 9 4.3 TT System Key T transformer P protection measures against electric shock. (i.e. RCD) Automatic disconnection according to HD 60364-4-4

44、1:2007, 411.5 1 class II equipment 2 conductive housing 3 direct connection to PE Figure 2 Example of SPDs connected to PE protecting Class II equipments in TT System L N PE P 3 1 2 x x T SPD Assembly PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 10 4.4 IT System Key T transformer Z high Impedance IMD i

45、nsulation Monitoring Device 1 class II equipment 2 conductive housing 3 direct connection to PE Figure 3 Example of SPDs connected to PE protecting Class II equipments in IT System L N PE 3 1 2 T Z + IMD SPD Assembly PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 11 4.5 Example of lighting pole surge pro

46、tection connected to PE Key 1 SPD 2 Junction box 3 Class II head light (may have a metallic outer surface) 4 Conductive housing (a: not fulfilling and b: fulfilling the PE requirements) 5 Protection measures against electric shock depending on system (See 4.2 and 4.3) Figure 4 Example of SPDs connec

47、ted to PE protecting Class II head luminary The SPD can be located in connection volume of the Class II head light where double or reinforced insulation is achieved between the SPD and the light head. 5 SPDs not connected to PE for the protection of Class II equipments 5.1 General The SPD used in su

48、ch installation shall comply with EN 61643-11 and in addition should fulfill the requirements from Clause 6 if the SPD itself is not part of the class II equipment. The installation rules described in HD 60364-5-534 shall be applied, and in addition the rules related to surge protection described in

49、 CLC/TS 61643-12 are applicable. PD CLC/TR 50656:2016CLC/TR 50656:2016 (E) 12 5.2 Examples Key T transformer 1 class II equipment including cable according to HD 60364-4-41:2007, Clause 412. No additional protective measure against electric shock 2 conductive housing may be unintentionally earthed (not a part of class II) NOTE In this figure, the SPD is mounted into a separate Class II enclosure or provides itself a housing that complies with Class II requirements. Figure 5 Example of SPDs to be installed

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1