1、CEN PREN*259L (PARTiBb) 92 D 3404589 0033524 593 i - Approved by COMITE DE NORMALISATION Of A.E.C.M.A. 1992-1 1-02 A. E. C. M. A. STAN DA FI D NORME A.E.C.M.A. A.E.C.M.A. NORM - lhe equivalent yeislons in French and German tanguager can be supplied by 6 N A E - Technopalls 54 - 199. rue Jean Jacques
2、 Rousseau 92138 ISSY LES MOULINEAUX GEOEX - FRANCE prEN 2 Part B Edition November $DITE PAR LASSOCIATION EUROPEENNE DES CONSTRUCTEURS DE MATeRIEL AcROSPATIAL Teclinopolis - 175, rue Jean-Jacques Rousseau - F-92138 Issy-les-Moulineaux Cdex - Tl. (1) 47.36.98.76 UDC: 621.316.541 : 681.3: 620.1 Key wor
3、ds : Aircraft industry. aircraft equipment, connecting equipment, tests, measurements, in3 resistance . ENGLISH VERSION Aerospace series Elements of electrica end optical connection Test methods Part B6 - Measurement of insulation resistance Srie arospatiale Organes de connexion lectrique et optique
4、 Mthodes dessais Partie B6 - Mesure de la rsistance disolement Luft- und Raumfahrt Elektrische und optische Verbindungselemente Prfverfa hren Teil 86 - Messung des Isolations- Widerstandes This .Aerospace series. standard has been drawn up under the responsibilir y of AECMA (Associa Europenne des Co
5、nstructeurs de Matdriel Arospatial). It is published on yellow paper in three equivalent versions (English, French, German). It will be submitted as a draft European Standard to CEN(Europeen Committee for Standardirar for final vote. Copyright Association Europeene des Constructeurs de Materiel Aero
6、spatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CEN PRENx259L (PARTSBb) 92 W 3404589 0033525 42T -_ prEN 2591-B6 Page 3 1 Scope and field of application This standard specifies a method for measuring the insulation re
7、sistance of mated or unmated elements of connection. It shall be used together with EN 259 1. 2 References EN 2591 Aerospace series - Elements of electrical and optical connection - Test methods - General 3 Preparation of specimens 3.1 Specimens shall be wired in conformance with the technical speci
8、fication. Measurements shall be carried out on elements of connection which are mated or unmated in accordance with the technical specification. Unless otherwise specified in the test concerned, the specimens shall not be cleaned. 3.2 Unless indicated in the technical specification, the following de
9、tails shall be specified : - measuring method (A, B or C) to be used, - elements of connection mated or unmated, - minimum value of the insulation resistance specified by the test concerned, e.g. environmental , contamination, temperature, moisture tests, etc. 4 Methods + 20 The insulation resistanc
10、e shall be measured under (500 o 1 V d.c. The insulation resistance shall be recorded when a stable reading is obtained. If a stable cond+i&on is not reached, the insulation resistance reading shall be recorded within (60 o) s after application of test voltage. 4.1 Method A The insulation resistance
11、 shall be measured in turn between each contact and all the others connected together and to the housing (shell) or the mounting plate. 4.2 Method 3 Alternate contacts shall be connected together to form two groups, the first group including all even numbered contacts, the other all odd numbered con
12、tacts for instance. Previous page is blank Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CEN PREN*2591 CPART*Bb 72 D 3LiOLi559 0035402 82b = prEN 259
13、1-B6 Page 4 The insulation resistance shall be measured in turn between : - the first group of contacts and the second group connected to the housing (shell) or to the mounting plate, - the second group of contacts and the first group connected to the housing (shell) or to tt ie mounting plate. In t
14、he case of contacts arranged in two or more rows, it may be necessary to form a second arrangement of two groups in order to measure the insulation resistance between all adjacent contacts. 4.3 Method C ThG insulation resistance shall be measured between two adjacent contacts or one contact and the
15、housing (shell) having a minimum spacing. 4.4 Requirement The measured value shall not be lower than that specified. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-